Adaptive comb filtering for motion artifact reduction from PPG with a structure of adaptive lattice IIR notch filter

Photoplethysmographic (PPG) signal can provide important information about cardiovascular and respiratory conditions of individuals in a hospital or daily life. However, PPG can be distorted by motion artifacts significantly. Therefore, the reduction of the effects of motion artifacts is very important procedure for monitoring cardio-respiratory system by PPG. There have been many adaptive techniques to reduce motion artifacts from PPG signal including normalized least mean squares (NLMS) method, recursive least squares (RLS) filter, and Kalman filter. In the present study, we propose the adaptive comb filter (ACF) for reducing the effects of motion artifacts from PPG signal. ACF with adaptive lattice infinite impulse response (IIR) notch filter (ALNF) successfully reduced the motion artifacts from the quasi-periodic PPG signal.

[1]  Boreom Lee,et al.  Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors , 2010, Physiological measurement.

[2]  Boreom Lee,et al.  Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry , 2010, Physiological measurement.

[3]  A. K. Mohd Omar,et al.  Mass Transfer Modeling in a Packed Bed of Palm Kernels under Supercritical Conditions , 2009 .

[4]  Jong Yong Abdiel Foo Comparison of wavelet transformation and adaptive filtering in restoring artefact-induced time-related measurement , 2006, Biomed. Signal Process. Control..

[5]  K. Shelley Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate , 2007, Anesthesia and analgesia.

[6]  H. Harry Asada,et al.  Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers , 2005, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[7]  S. Seyedtabaii,et al.  Kalman Filter Based Adaptive Reduction of Motion Artifact from Photoplethysmographic Signal , 2008 .

[8]  K. Chon,et al.  Can Photoplethysmography Variability Serve as an Alternative Approach to Obtain Heart Rate Variability Information? , 2008, Journal of Clinical Monitoring and Computing.

[9]  H Harry Asada,et al.  Mobile monitoring with wearable photoplethysmographic biosensors. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[10]  Nam Ik Cho,et al.  Tracking analysis of an adaptive lattice notch filter , 1995 .

[11]  M. J. Hayes,et al.  Artefact reduction in photoplethysmography , 1998 .

[12]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[13]  Arye Nehorai,et al.  Adaptive comb filtering for harmonic signal enhancement , 1986, IEEE Trans. Acoust. Speech Signal Process..