Development of an algorithm to regulate pump output for a closed air-loop type pneumatic biventricular assist device.

The closed air space-type of extracorporeal pneumatic ventricular assist device (VAD) developed by the Korea Artificial Organ Center utilizes a bellows-transforming mechanism to generate the air pressure required to pump blood. This operating mechanism can reduce the size and weight of the driving unit; however, the output of the blood pump can be affected by the pressure loading conditions of the blood sac. Therefore, to guarantee a proper pump output level, regardless of the pressure loading conditions that vary over time, automatic pump output regulation of the blood pump is required. We describe herein a pump output regulation algorithm that was developed to maintain pump output around a reference level against various afterload pressures, and verified the pump performance in vitro. Based on actual operating conditions in animal experiments, the pumping rate was limited to 40-84 beats per minute, and the afterload pressure was limited to 80-150 mm Hg. The tested reference pump output was 4.0 L/min. During experiments, the pump output was successfully and automatically regulated within the preset area regardless of the varying afterload conditions. The results of this preliminary experiment can be used as the basis for an automatic control algorithm that can enhance the stability and reliability of the applied VAD.

[1]  R L Kormos,et al.  Asssessment of Timing Right Ventricular Assist Device Withdrawal Using Left Ventricular Assist Device Filling Characteristics , 1997, ASAIO journal.

[2]  Steven Deutsch,et al.  The 12 cc Penn State pulsatile pediatric ventricular assist device: fluid dynamics associated with valve selection. , 2008, Journal of biomechanical engineering.

[3]  Danny Bluestein,et al.  Research approaches for studying flow-induced thromboembolic complications in blood recirculating devices , 2004, Expert review of medical devices.

[4]  J. Maessen,et al.  Suction due to left ventricular assist: implications for device control and management. , 2007, Artificial organs.

[5]  Y Nosé,et al.  High-pressure portable pneumatic drive unit. , 2008, Artificial organs.

[6]  Eisuke Tatsumi,et al.  Development of a compact portable driver for a pneumatic ventricular assist device , 2007, Journal of Artificial Organs.

[7]  Z. Zachariou,et al.  Hemostasis management in pediatric mechanical circulatory support. , 2008, The Annals of thoracic surgery.

[8]  K.S. Om,et al.  Static State Hemodynamic Variables Estimation Model for the Moving-Actuator Type Total Artificial Heart: Part. I - Cardiac output estimation , 1998, The International journal of artificial organs.

[9]  K. Miller,et al.  CLINICAL EVALUATION OF A NEW PNEUMATIC PORTABLE DRIVER, THE TCI HEARTPAK™ , 1997 .

[10]  J. Copeland,et al.  Biventricular cannulation for the Thoratec ventricular assist device. , 1998, The Annals of thoracic surgery.

[11]  Steven Deutsch,et al.  Correlation of In Vivo Clot Deposition With the Flow Characteristics in the 50 cc Penn State Artificial Heart: A Preliminary Study , 2004, ASAIO journal.

[12]  S. Deutsch,et al.  The 12 cc Penn State Pulsatile Pediatric Ventricular Assist Device: Flow Field Observations at a Reduced Beat Rate With Application to Weaning , 2008, ASAIO journal.

[13]  K E Buck,et al.  Portable Pneumatic Biventricular Driver for the Thoratec Ventricular Assist Device , 1997, ASAIO journal.