Magnetoencephalography recording and analysis

Magnetoencephalography (MEG) non-invasively measures the magnetic field generated due to the excitatory postsynaptic electrical activity of the apical dendritic pyramidal cells. Such a tiny magnetic field is measured with the help of the biomagnetometer sensors coupled with the Super Conducting Quantum Interference Device (SQUID) inside the magnetically shielded room (MSR). The subjects are usually screened for the presence of ferromagnetic materials, and then the head position indicator coils, electroencephalography (EEG) electrodes (if measured simultaneously), and fiducials are digitized using a 3D digitizer, which aids in movement correction and also in transferring the MEG data from the head coordinates to the device and voxel coordinates, thereby enabling more accurate co-registration and localization. MEG data pre-processing involves filtering the data for environmental and subject interferences, artefact identification, and rejection. Magnetic resonance Imaging (MRI) is processed for correction and identifying fiducials. After choosing and computing for the appropriate head models (spherical or realistic; boundary/finite element model), the interictal/ictal epileptiform discharges are selected and modeled by an appropriate source modeling technique (clinically and commonly used — single equivalent current dipole — ECD model). The equivalent current dipole (ECD) source localization of the modeled interictal epileptiform discharge (IED) is considered physiologically valid or acceptable based on waveform morphology, isofield pattern, and dipole parameters (localization, dipole moment, confidence volume, goodness of fit). Thus, MEG source localization can aid clinicians in sublobar localization, lateralization, and grid placement, by evoking the irritative/seizure onset zone. It also accurately localizes the eloquent cortex-like visual, language areas. MEG also aids in diagnosing and delineating multiple novel findings in other neuropsychiatric disorders, including Alzheimer's disease, Parkinsonism, Traumatic brain injury, autistic disorders, and so oon.

[1]  M. Scherg,et al.  Evoked dipole source potentials of the human auditory cortex. , 1986, Electroencephalography and clinical neurophysiology.

[2]  H. Akaike A new look at the statistical model identification , 1974 .

[3]  B. Rockstroh,et al.  Abnormal oscillatory brain dynamics in schizophrenia: a sign of deviant communication in neural network? , 2007, BMC psychiatry.

[4]  A. Dale,et al.  Improved Localizadon of Cortical Activity by Combining EEG and MEG with MRI Cortical Surface Reconstruction: A Linear Approach , 1993, Journal of Cognitive Neuroscience.

[5]  田中 秀明,et al.  Low Resolution Brain Electromagnetic Tomography(LORETA)をもちいた脳機能マッピングの新たな展開 , 2002 .

[6]  K. Amunts,et al.  Towards multimodal atlases of the human brain , 2006, Nature Reviews Neuroscience.

[7]  H. Otsubo,et al.  Magnetoencephalography-guided epilepsy surgery for children with intractable focal epilepsy: SickKids experience. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[8]  Maeike Zijlmans,et al.  Modality-specific Spike Identification in Simultaneous Magnetoencephalography/Electroencephalography: A Methodological Approach , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[9]  R M Leahy,et al.  EEG source localization and imaging using multiple signal classification approaches. , 1999, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[10]  J. Lewine,et al.  CHAPTER 9 – Magnetoencephalography and Magnetic Source Imaging , 1995 .

[11]  M. E. Spencer,et al.  A Study of Dipole Localization Accuracy for MEG and EEG using a Human Skull Phantom , 1998, NeuroImage.

[12]  Robert C. Knowlton,et al.  American Clinical Magnetoencephalography Society Clinical Practice Guideline 3: MEG–EEG Reporting* , 2011, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[13]  B. Rockstroh,et al.  Source distribution of neuromagnetic slow-wave activity in schizophrenic patients—effects of activation , 2003, Schizophrenia Research.

[14]  M. Balish,et al.  Principles of Magnetoencephalography , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[15]  José Maria Fernandes,et al.  What Does an Epileptiform Spike Look Like in MEG? Comparison Between Coincident EEG and MEG Spikes , 2005, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[16]  C. Barillot,et al.  Registration of MEG/EEG data with 3D MRI: Methodology and precision issues , 1996, Brain Topography.

[17]  R. Ilmoniemi,et al.  Signal-space projection method for separating MEG or EEG into components , 1997, Medical and Biological Engineering and Computing.

[18]  M. Fuchs,et al.  Development of Volume Conductor and Source Models to Localize Epileptic Foci , 2007, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[19]  L. Parkkonen,et al.  122-channel squid instrument for investigating the magnetic signals from the human brain , 1993 .

[20]  H. Freund,et al.  The cerebral oscillatory network of parkinsonian resting tremor. , 2003, Brain : a journal of neurology.

[21]  Heidi E Kirsch,et al.  Resting functional connectivity in patients with brain tumors in eloquent areas , 2011, Annals of neurology.

[22]  P. Anninos,et al.  MEG evaluation of Parkinson's diseased patients after external magnetic stimulation. , 2007, Acta neurologica Belgica.

[23]  Peter C. Hansen,et al.  MEG. An introduction to methods , 2010 .

[24]  Anto Bagic,et al.  American Clinical MEG Society (ACMEGS) position statement: the value of magnetoencephalography (MEG)/magnetic source imaging (MSI) in noninvasive presurgical evaluation of patients with medically intractable localization-related epilepsy. , 2009, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[25]  J Mazziotta,et al.  A probabilistic atlas and reference system for the human brain: International Consortium for Brain Mapping (ICBM). , 2001, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[26]  John S Ebersole,et al.  Clinical Application of Dipole Models in the Localization of Epileptiform Activity , 2007, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.