Current deflection NDE for the inspection and monitoring of pipes
暂无分享,去创建一个
[1] Gary L. Burkhardt,et al. Remote-Field Eddy Current Inspection Tool for Small-Diameter Unpiggable Pipelines , 2008 .
[2] P. S. Ong,et al. Quantitative characterization of corrosion under insulation , 1997 .
[3] Uwe Ewert,et al. Corrosion monitoring with tangential radiography and limited view computed tomography , 2016 .
[4] D. Jiles. Theory of the magnetomechanical effect , 1995 .
[5] Zbigniew Usarek,et al. Discussion of Derivability of Local Residual Stress Level from Magnetic Stray Field Measurement , 2015 .
[6] Martin C. Lugg,et al. The First 20 years of the A.C. field Measurement Technique , 2008 .
[7] George Vradis,et al. Robotic Inspection of Unpiggable Natural Gas Transmission and Distribution Pipeline , 2010 .
[8] G. G. Stokes. "J." , 1890, The New Yale Book of Quotations.
[9] J. Lenz,et al. Magnetic sensors and their applications , 2006, IEEE Sensors Journal.
[10] Amir Movafeghi,et al. The use of radiography for thickness measurement and corrosion monitoring in pipes , 2006 .
[11] P. Cawley,et al. Rapid, Long Range Inspection of Chemical Plant Pipework Using Guided Waves , 2001 .
[12] Satish Udpa,et al. Advanced signal processing of magnetic flux leakage data obtained from seamless gas pipeline , 2002 .
[13] Albert Teitsma,et al. Small Diameter Remote Field Eddy Current Inspection for Unpiggable Pipelines , 2005 .
[14] S. Freear,et al. Solving the inverse problem of magnetisation–stress resolution , 2013 .
[15] Jiqiang Guo,et al. High-quality image reconstruction from exterior helical cone-beam CT data for NDE of industrial pipelines , 2011 .
[16] M. Lowe,et al. Defect detection in pipes using guided waves , 1998 .
[17] Wenhua Han. A new denoising algorithm for MFL data obtained from seamless pipeline inspection , 2008 .
[18] Anthony N Sinclair,et al. Ultrasonic monitoring of erosion/corrosion thinning rates in industrial piping systems. , 2013, Ultrasonics.
[19] Gui Yun Tian,et al. Investigation of pitting corrosion monitoring using field signature method , 2016 .
[20] Hossam A. Gabbar,et al. Review of pipeline integrity management practices , 2010 .
[21] Gui Yun Tian,et al. Pulsed electromagnetic methods for defect detection and characterisation , 2007 .
[22] Uwe Ewert,et al. Radiographic Evaluation of Corrosion and Deposits in Pipelines: Results of an IAEA Co-ordinated Research Programme , 2006 .
[23] Yuanying Chen,et al. Rapid evolution of piRNA clusters in the Drosophila melanogaster ovary , 2023, bioRxiv.
[24] H. A. Wheeler. Formulas for the Skin Effect , 1942, Proceedings of the IRE.
[25] Douglas G Altman,et al. Standard deviations and standard errors , 2005, BMJ : British Medical Journal.
[26] Yong Li,et al. Gradient-field pulsed eddy current probes for imaging of hidden corrosion in conductive structures , 2016 .
[27] P. Cawley,et al. Ultrasonic isolation of buried pipes , 2016 .
[28] D. C. Jiles. ERRATUM: Theory of the magnetomechanical effect , 1999 .
[29] Weiying Cheng,et al. Pulsed Eddy Current Testing of Carbon Steel Pipes’ Wall-thinning Through Insulation and Cladding , 2012 .
[30] R. Polikar,et al. Adaptive noise cancellation schemes for magnetic flux leakage signals obtained from gas pipeline inspection , 2001, 2001 IEEE International Conference on Acoustics, Speech, and Signal Processing. Proceedings (Cat. No.01CH37221).
[31] Peter Cawley,et al. Practical long range guided wave testing: applications to pipes and rails , 2003 .
[32] R LeTessier,et al. Sizing of cracks using the alternating current field measurement technique , 2002 .
[33] Kjell Wold,et al. Fsm Technology - 16 Years Of Field History-Experience, Status And Further Developments. , 2007 .
[34] C. Farias,et al. Corrosion Inspection Using Pulsed Eddy Current , 2014 .
[35] Dominique Lesselier,et al. Electromagnetic Nondestructive Evaluation , 1999 .
[36] J Quarini,et al. A Review of Fluid-Driven Pipeline Pigs and their Applications , 2007 .
[37] I. Kolesnikov. Magnetic Tomography Method (MTM) &ndash A Remote Non-destructive Inspection Technology for Buried and Sub Sea Pipelines , 2014 .
[38] Peter Cawley,et al. Potential drop mapping for the monitoring of corrosion or erosion , 2010 .
[39] D. H. Michael,et al. Thin‐skin electromagnetic fields around surface‐breaking cracks in metals , 1988 .
[40] T. Bouma,et al. Rapid corrosion screening in up to 30 mm wall thickness for plates and pipe , 2002 .
[41] M. S. Safizadeh,et al. GAS PIPELINE CORROSION MAPPING USING PULSED EDDY CURRENT TECHNIQUE , 2011 .