Correlation between dissolved gases and oil spectral response

Spectroscopy is a powerful non-destructive technique that utilizes electromagnetic radiation interaction effect to determine the energy level and structure of atomic or molecular substance. Spectroscopy technique has been successfully used to quantify some power transformer condition monitoring parameters such as Furan and oil interfacial tension value. This paper investigates the feasibility of extending the applications of this technique to identify and quantify various dissolved gases in the transformer oil. In this context, several transformer oil samples with various gases concentrations have been prepared. Dissolved gases in each sample were first quantified using gas chromatography-mass spectrometry (GC/MS) laboratory measurement technique. The spectral response of each sample was then measured using UV-NIR and FTIR spectroscopy. Correlation between oil spectral response and the concentration of each gas is realized using adaptive neuro fuzzy inference system (ANFIS).

[1]  Ahmed Abu-Siada,et al.  Fuzzy Logic Approach for Power Transformer Asset Management Based on Dissolved Gas-in-oil Analysis , 2013 .

[2]  Amin Gholami,et al.  Genetic optimization of neural network and fuzzy logic for oil bubble point pressure modeling , 2014, Korean Journal of Chemical Engineering.

[3]  B. Galle,et al.  Measurements of methane emissions from landfills using a time correlation tracer method based on FTIR absorption spectroscopy. , 2001, Environmental science & technology.

[4]  Brian C. Smith Fundamentals of Fourier Transform Infrared Spectroscopy , 1995 .

[5]  Ahmad Hajinezhad,et al.  ANN and ANFIS models to predict the performance of solar chimney power plants , 2015 .

[6]  Syed Islam,et al.  Remnant life estimation of power transformer using oil UV-Vis spectral response , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[7]  A. Abu-Siada,et al.  A Novel Fuzzy-Logic Approach for Furan Estimation in Transformer Oil , 2012, IEEE Transactions on Power Delivery.

[8]  A. Abu-Siada,et al.  Correlation between UV-Vis spectral response and furan measurement of transformer oil , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[9]  A. Abu-Siada,et al.  Furan measurement in transformer oil by UV-Vis spectral response using Fuzzy Logic , 2008, 2008 International Conference on Electrical and Computer Engineering.

[10]  Jyh-Shing Roger Jang,et al.  ANFIS: adaptive-network-based fuzzy inference system , 1993, IEEE Trans. Syst. Man Cybern..

[11]  J. Mohan,et al.  Organic Spectroscopy: Principles And Applications , 2000 .

[12]  Syed Islam,et al.  Impact of conducting materials on furan-spectral correlation of transformer oil , 2013, 2013 Australasian Universities Power Engineering Conference (AUPEC).

[13]  Ahmed Abu-Siada,et al.  Correlation of furan concentration and spectral response of transformer oil-using expert systems , 2011 .

[14]  A. Abu-Siada,et al.  A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  A. Abu-Siada,et al.  A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.