Effect of microchannel aspect ratio on residence time distributions and the axial dispersion coefficient

Abstract The effect of microchannel aspect ratio (channel depth/channel width) on residence time distributions and the axial dispersion coefficient have been investigated for Newtonian and shear-thinning non-Newtonian flow using computational fluid dynamics. The results reveal that for a fixed cross-sectional area and throughput, there is a narrowing of the residence time distribution as the aspect ratio decreases. This is quantified by an axial dispersion coefficient that increases rapidly for aspect ratios less than 0.3 and then tends towards an asymptote as the aspect ratio goes to 1. The results also show that the axial dispersion coefficient is related linearly to the Reynolds number when either the aspect ratio or the mean fluid velocity is varied. However, the fluid Peclet number is a linear function of the Reynolds number only when the aspect ratio (and therefore hydraulic diameter) is varied. Globally, the results indicate that microchannels should be designed with low aspect ratios (≤0.3) for reduced axial dispersion.

[1]  D. Leighton,et al.  Dispersion reduction in pressure-driven flow through microetched channels. , 2001, Analytical chemistry.

[2]  Steffen Hardt,et al.  Helical Flows and Chaotic Mixing in Curved Micro Channels , 2004 .

[3]  Simsoo Park,et al.  Experimental and numerical investigations of pressure drop in a rectangular duct with modified power law fluids , 2003 .

[4]  S. Middleman,et al.  Correlation of Shear Behavior of Solutions of Polyisobutylene , 1966 .

[5]  J. Aubin,et al.  Design of micromixers using CFD modelling , 2005 .

[6]  R. Shah Laminar Flow Forced convection in ducts , 1978 .

[7]  Asterios Gavriilidis,et al.  Mixing characteristics of T-type microfluidic mixers , 2001 .

[8]  Asterios Gavriilidis,et al.  Design of a mesh microreactor for even flow distribution and narrow residence time distribution , 2006 .

[9]  Klavs F. Jensen,et al.  Measurement of residence time distribution in microfluidic systems , 2005 .

[10]  Dusan Boskovic,et al.  Modelling of the residence time distribution in micromixers , 2008 .

[11]  M. Hohmann,et al.  Designing Microreactors in Chemical Synthesis – Residence-time Distribution of Microchannel Devices , 2005 .

[12]  H. S. Fogler,et al.  Elements of Chemical Reaction Engineering , 1986 .

[13]  T. Henkel,et al.  Characterisation of residence time and residence time distribution in chip reactors with modular arrangements by integrated optical detection , 2004 .

[14]  M. Matlosz,et al.  Gas-phase residence time distribution in a falling-film microreactor , 2006 .

[15]  G. Taylor Dispersion of soluble matter in solvent flowing slowly through a tube , 1953, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[16]  K. Nigam,et al.  RTD for diffusion-free laminar flow of non-newtonian fluids through coiled tubes , 1983 .

[17]  David F. Fletcher,et al.  Thermohydraulics of square-section microchannels following a serpentine path , 2006 .

[18]  Saif A. Khan,et al.  Transport and reaction in microscale segmented gas-liquid flow. , 2004, Lab on a chip.

[19]  Adeniyi Lawal,et al.  Mass transfer enhancement in microchannel reactors by reorientation of fluid interfaces and stretching , 2005 .

[20]  P. Legentilhomme,et al.  Residence time distribution of a purely viscous non-Newtonian fluid in helically coiled or spatially chaotic flows , 2006 .

[21]  Debashis Dutta,et al.  Effect of channel geometry on solute dispersion in pressure-driven microfluidic systems , 2006 .

[22]  David A. Weitz,et al.  Mixing characterization inside microdroplets engineered on a microcoalescer , 2007 .

[23]  A. Gavriilidis,et al.  Axial mass transfer in Taylor flow through circular microchannels , 2007 .

[24]  Jerry M Chen,et al.  Analysis and measurements of mixing in pressure-driven microchannel flow , 2006 .

[25]  J. J. Ulbrecht,et al.  VELOCITY PROFILES OF NEWTONIAN AND NON-NEWTONIAN TOROIDAL FLOWS MEASURED BY A LDA TECHNIQUE , 1983 .

[26]  Asterios Gavriilidis,et al.  Sample pulse broadening in taylor flow microchannels for screening applications , 2005 .