FT-IR-cPAS—New Photoacoustic Measurement Technique for Analysis of Hot Gases: A Case Study on VOCs

This article describes a new photoacoustic FT-IR system capable of operating at elevated temperatures. The key hardware component is an optical-readout cantilever microphone that can work up to 200 °C. All parts in contact with the sample gas were put into a heated oven, incl. the photoacoustic cell. The sensitivity of the built photoacoustic system was tested by measuring 18 different VOCs. At 100 ppm gas concentration, the univariate signal to noise ratios (1σ, measurement time 25.5 min, at highest peak, optical resolution 8 cm−1) of the spectra varied from minimally 19 for o-xylene up to 329 for butyl acetate. The sensitivity can be improved by multivariate analyses over broad wavelength ranges, which effectively co-adds the univariate sensitivities achievable at individual wavelengths. The multivariate limit of detection (3σ, 8.5 min, full useful wavelength range), i.e., the best possible inverse analytical sensitivity achievable at optimum calibration, was calculated using the SBC method and varied from 2.60 ppm for dichloromethane to 0.33 ppm for butyl acetate. Depending on the shape of the spectra, which often only contain a few sharp peaks, the multivariate analysis improved the analytical sensitivity by 2.2 to 9.2 times compared to the univariate case. Selectivity and multi component ability were tested by a SBC calibration including 5 VOCs and water. The average cross selectivities turned out to be less than 2% and the resulting inverse analytical sensitivities of the 5 interfering VOCs was increased by maximum factor of 2.2 compared to the single component sensitivities. Water subtraction using SBC gave the true analyte concentration with a variation coefficient of 3%, although the sample spectra (methyl ethyl ketone, 200 ppm) contained water from 1,400 to 100k ppm and for subtraction only one water spectra (10k ppm) was used. The developed device shows significant improvement to the current state-of-the-art measurement methods used in industrial VOC measurements.

[1]  Paul J. Crutzen,et al.  The Role of NO and NO2 in the Chemistry of the Troposphere and Stratosphere , 1979 .

[2]  Juho Uotila,et al.  Fourier Transform Infrared Photoacoustic Multicomponent Gas Spectroscopy with Optical Cantilever Detection , 2010, Applied spectroscopy.

[3]  K. Roth,et al.  Cantilever enhanced photoacoustic detection of carbon dioxide using a tunable diode laser source , 2007 .

[4]  R. Marbach A New Method for Multivariate Calibration , 2005 .

[5]  J. Vercammen,et al.  On-line analysis of complex hydrocarbon mixtures using comprehensive two-dimensional gas chromatography. , 2010, Journal of chromatography. A.

[6]  V. Koskinen,et al.  High sensitivity in gas analysis with photoacoustic detection , 2004 .

[7]  A. Parkes,et al.  A sensitivity comparison of three photoacoustic cells containing a single microphone, a differential dual microphone or a cantilever pressure sensor , 2007 .

[8]  Jyrki Kauppinen,et al.  Selective differential photoacoustic method for trace gas analysis , 2005 .

[9]  Jyrki Kauppinen,et al.  Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy , 2006 .

[10]  Jyrki Kauppinen,et al.  Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone , 2007 .

[11]  R. Swannell,et al.  Volatile organic compound (VOC) emissions during malting and beer manufacture , 1995 .

[12]  Riitta L. Keiski,et al.  Catalysis in VOC Abatement , 2011 .

[13]  R Lebrero,et al.  Monitoring techniques for odour abatement assessment. , 2010, Water research.

[14]  S Ojala,et al.  Testing VOC emission measurement techniques in wood-coating industrial processes and developing a cost-effective measurement methodology. , 2006, Chemosphere.

[15]  V. Gold Compendium of chemical terminology , 1987 .

[16]  P. Griffiths Fourier Transform Infrared Spectrometry , 2007 .

[17]  York Neubauer,et al.  Analysis of gas-phase polycyclic aromatic hydrocarbon mixtures by laser-induced fluorescence , 2010 .

[18]  Jyrki Kauppinen,et al.  Diode laser-based photoacoustic spectroscopy with interferometrically-enhanced cantilever detection. , 2005, Optics express.

[19]  Ralf Marbach,et al.  Multivariate Kalibrierung, Selektivität und die SBC‐Methode , 2010 .

[20]  Jyrki Kauppinen,et al.  Optimization of a Microphone for Photoacoustic Spectroscopy , 2003, Applied spectroscopy.

[21]  Faisal Khan,et al.  Removal of Volatile Organic Compounds from polluted air , 2000 .

[22]  Ronald E. Hester,et al.  Volatile organic compounds in the atmosphere , 1995 .

[23]  E. C. Moretti,et al.  VOC Control: Current practices and future trends , 1993 .

[24]  K. Roth,et al.  Dual cantilever enhanced photoacoustic detector with pulsed broadband IR-source , 2009 .

[25]  Ralf Marbach,et al.  On Wiener filtering and the physics behind statistical modeling. , 2002, Journal of biomedical optics.

[26]  V. Koskinen,et al.  Progress in cantilever enhanced photoacoustic spectroscopy , 2008 .

[27]  J. D. Winefordner,et al.  Limit of detection. A closer look at the IUPAC definition , 1983 .

[28]  J. V. D. Lugt,et al.  Emissions of volatile organic compounds (VOCs) from the food and drink industries of the European community , 1993 .

[29]  Erika von Schneidemesser,et al.  Global comparison of VOC and CO observations in urban areas , 2010 .

[30]  Juho Uotila,et al.  Comparison of infrared sources for a differential photoacoustic gas detection system , 2007 .