Electron spin relaxation of triarylmethyl radicals in fluid solution.

Electron spin relaxation times of a Nycomed triarylmethyl radical (sym-trityl) in water, 1:1 water:glycerol, and 1:9 water:glycerol were measured at L-band, S-band, and X-band by pulsed EPR methods. In H(2)O solution, T(1) is 17+/-1 micros at X-band at ambient temperature, is nearly independent of microwave frequency, and exhibits little dependence on viscosity. The temperature dependence of T(1) in 1:1 water:glycerol is characteristic of domination by a Raman process between 20 and 80 K. The increased spin-lattice relaxation rates at higher temperatures, including room temperature, are attributed to a local vibrational mode that modulates spin-orbit coupling. In H(2)O solution, T(2) is 11+/-1 micros at X-band, increasing to 13+/-1 micros at L-band. For more viscous solvent mixtures, T(2) is much shorter than T(1) and weakly frequency dependent, which indicates that incomplete motional averaging of hyperfine anisotropy makes a significant contribution to T(2). In water and 1:1 water:glycerol solutions continuous wave EPR linewidths are not relaxation determined, but become relaxation determined in the higher viscosity 1:9 water:glycerol solutions. The Lorentzian component of the 250-MHz linewidths as a function of viscosity is in good agreement with T(2)-determined contributions to the linewidths at higher frequencies.

[1]  James B. Mitchell,et al.  300 MHz continuous wave electron paramagnetic resonance spectrometer for small animal in vivo imaging , 2000 .

[2]  R. Griffin,et al.  High-frequency dynamic nuclear polarization in the nuclear rotating frame. , 2000, Journal of magnetic resonance.

[3]  B. Bowler,et al.  Electron spin-lattice relaxation rates for high-spin Fe(III) complexes in glassy solvents at temperatures between 6 and 298 K. , 2000, Journal of magnetic resonance.

[4]  James B. Mitchell,et al.  Three‐dimensional whole body imaging of spin probes in mice by time‐domain radiofrequency electron paramagnetic resonance , 2000, Magnetic resonance in medicine.

[5]  J. Harbridge,et al.  Frequency dependence of EPR signal-to-noise. , 1999, Journal of magnetic resonance.

[6]  G. Rinard,et al.  Absolute EPR spin echo and noise intensities. , 1999, Journal of magnetic resonance.

[7]  B H Robinson,et al.  Linewidth analysis of spin labels in liquids. I. Theory and data analysis. , 1999, Journal of magnetic resonance.

[8]  B H Robinson,et al.  Linewidth analysis of spin labels in liquids. II. Experimental. , 1999, Journal of magnetic resonance.

[9]  R Murugesan,et al.  High-speed data acquisition system and receiver configurations for time-domain radiofrequency electron paramagnetic resonance spectroscopy and imaging. , 1999, Journal of magnetic resonance.

[10]  M. Lindgren,et al.  Dephasing of electron spin echoes for nitroxyl radicals in glassy solvents by non-methyl and methyl protons , 1998 .

[11]  James B. Mitchell,et al.  A broadband pulsed radio frequency electron paramagnetic resonance spectrometer for biological applications , 1998 .

[12]  J S Petersson,et al.  EPR and DNP properties of certain novel single electron contrast agents intended for oximetric imaging. , 1998, Journal of magnetic resonance.

[13]  Krishna,et al.  FT-EPR with a Nonresonant Probe: Use of a Truncated Coaxial Line. , 1998, Journal of magnetic resonance.

[14]  R Murugesan,et al.  In vivo imaging of a stable paramagnetic probe by pulsed‐radiofrequency electron paramagnetic resonance spectroscopy , 1997, Magnetic resonance in medicine.

[15]  J. Zweier,et al.  High resolution electron paramagnetic resonance imaging of biological samples with a single line paramagnetic label , 1997, Magnetic resonance in medicine.

[16]  G. Rinard,et al.  Easily Tunable Crossed-Loop (Bimodal) EPR Resonator , 1996 .

[17]  G. Rinard,et al.  Dispersion and Superheterodyne EPR Using a Bimodal Resonator , 1996 .

[18]  George A. Rinard,et al.  A 1–2 GHz pulsed and continuous wave electron paramagnetic resonance spectrometer , 1996 .

[19]  H J Halpern,et al.  Oxymetry deep in tissues with low-frequency electron paramagnetic resonance. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[20]  W. Froncisz,et al.  Relative Benefits of Overcoupled Resonators vs Inherently Low-Q Resonators for Pulsed Magnetic Resonance , 1994 .

[21]  B. Robinson,et al.  Molecular dynamics in liquids: spin-lattice relaxation of nitroxide spin labels. , 1994, Science.

[22]  R. Quine,et al.  Saturation recovery electron paramagnetic resonance spectrometer , 1992 .

[23]  Howard J. Halpern,et al.  Imaging radio frequency electron‐spin‐resonance spectrometer with high resolution and sensitivity for in vivo measurements , 1989 .

[24]  R. Quine,et al.  Pulsed EPR spectrometer , 1987 .

[25]  B. Robinson,et al.  Computer-controlled pulsed electron-paramagnetic-resonance spectrometer , 1985 .

[26]  J. Hyde,et al.  A pulsed EPR spectrometer , 1974 .

[27]  J. G. Powles,et al.  Microwave Spin Echoes, Electron Spin Relaxation and Electron Diffusion in Metal-Ammonia Solutions , 1962 .

[28]  Y. Deguchi Proton Hyperfine Spectra of Diphenyl Picryl Hydrazyl , 1960 .

[29]  G. Feher,et al.  THE SPIN RELAXATION TIME OF TRIPHENYLMETHYL AT LOW TEMPERATURES1 , 1957 .

[30]  J. B. Segur,et al.  Viscosity of Glycerol and Its Aqueous Solutions , 1951 .

[31]  H. Halpern,et al.  EPR Studies of Living Animals and Related Model Systems ( In Vivo EPR) , 2002 .

[32]  S. Eaton,et al.  Relaxation Times of Organic Radicals and Transition Metal Ions , 2002 .

[33]  James B. Mitchell,et al.  Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects. , 2000, Journal of magnetic resonance.

[34]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[35]  J. S. Hyde,et al.  Spin-Label Oximetry , 1989 .