Laparoscopic Pectopexy: A Biomechanical Analysis

Introduction Pectopexy, a laparoscopic method for prolapse surgery, showed promising results in recent literature. Further improving this approach by reducing surgical time may decrease complication rates and patient morbidity. Since laparoscopic suturing is a time consuming task, we propose a single suture /mesh ileo-pectineal ligament fixation as opposed to the commonly used continues approach. Methods Evaluation was performed on human non-embalmed, fresh cadaver pelves. A total of 33 trials was performed. Eight female pelves with an average age of 75, were used. This resulted in 16 available ligaments. Recorded parameters were ultimate load, displacement at failure and stiffness. Results The ultimate load for the mesh + simplified single “interrupted” suture (MIS) group was 35 (± 12) N and 48 (± 7) N for the mesh + continuous suture (MCS) group. There was no significant difference in the ultimate load between both groups (p> 0.05). This was also true for displacement at failure measured at 37 (± 12) mm and 36 (±5) mm respectively. There was also no significant difference in stiffness and failure modes. Conclusion Given the data above we must conclude that a continuous suture is not necessary in laparoscopic mesh / ileo-pectineal ligament fixation during pectopexy. Ultimate load and displacement at failure results clearly indicate that a single suture is not inferior to a continuous approach. The use of two single sutures may improve ligamental fixation. However, overall stability should not benefit since the surgical mesh remains the limiting factor.

[1]  I. Alkatout,et al.  Laparoscopic pectopexy: a prospective, randomized, comparative clinical trial of standard laparoscopic sacral colpocervicopexy with the new laparoscopic pectopexy-postoperative results and intermediate-term follow-up in a pilot study. , 2015, Journal of endourology.

[2]  V. Sung,et al.  Urogynecology : Review Mesh Sacrocolpopexy Compared With Native Tissue Vaginal Repair A Systematic Review and Meta-analysis , 2022 .

[3]  G. Northington,et al.  Bowel and bladder dysfunction following surgery within the presacral space: an overview of neuroanatomy, function, and dysfunction , 2015, International Urogynecology Journal.

[4]  Michael M. Zimkowski,et al.  Biocompatibility and tissue integration of a novel shape memory surgical mesh for ventral hernia: in vivo animal studies. , 2014, Journal of biomedical materials research. Part B, Applied biomaterials.

[5]  D. Waltregny,et al.  A review of the current status of laparoscopic and robot-assisted sacrocolpopexy for pelvic organ prolapse. , 2014, European urology.

[6]  L. Mettler,et al.  Laparoscopic Hysterectomy and Prolapse: A Multiprocedural Concept , 2014, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[7]  J. Deprest,et al.  Mesh contraction: in vivo documentation of changes in apparent surface area utilizing meshes visible on magnetic resonance imaging in the rabbit abdominal wall model , 2014, International Urogynecology Journal.

[8]  M. Betsch,et al.  Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate. , 2013, Orthopedics.

[9]  Robin Shandas,et al.  Integrating a novel shape memory polymer into surgical meshes decreases placement time in laparoscopic surgery: an in vitro and acute in vivo study. , 2013, Journal of biomedical materials research. Part A.

[10]  M. Anapolski,et al.  Laparoscopic pectopexy: a randomised comparative clinical trial of standard laparoscopic sacral colpo-cervicopexy to the new laparoscopic pectopexy. Short-term postoperative results , 2013, Archives of Gynecology and Obstetrics.

[11]  M. Betsch,et al.  Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[12]  J. Koebke,et al.  Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures. , 2012, Injury.

[13]  M. Betsch,et al.  Fixed-angle plates in patella fractures - a pilot cadaver study , 2011, European journal of medical research.

[14]  S. Hagen,et al.  Surgical management of pelvic organ prolapse in women. , 2013, The Cochrane database of systematic reviews.

[15]  C. Banerjee,et al.  Laparoscopic pectopexy: a new technique of prolapse surgery for obese patients , 2011, Archives of Gynecology and Obstetrics.

[16]  P. Jungbluth,et al.  Fixed-angle plate osteosynthesis of the patella - an alternative to tension wiring? , 2010, Clinical biomechanics.

[17]  S. Hagen,et al.  Surgical management of pelvic organ prolapse in women. , 2009, The Cochrane database of systematic reviews.

[18]  G. Cundiff,et al.  Abdominal Sacrocolpopexy: A Comprehensive Review , 2004, Obstetrics and gynecology.

[19]  J. Fasel,et al.  A study of pelvic ligament strength. , 2003, European journal of obstetrics, gynecology, and reproductive biology.

[20]  J. C. Burch Urethrovaginal fixation to Cooper's ligament for correction of stress incontinence, cystocele, and prolapse. , 1961, American journal of obstetrics and gynecology.