Reduction of Induced Shaft Voltage and Bearing Current in Turbo Generators: Modeling, Compensation, and Practical Test

The static excitation system of a turbo generator, supplied by a rectifier, can cause induced voltages on the generator's shaft. This article proposes a complete distributed model of a turbo generator, regulated by a static excitation system, to investigate the shaft voltage and bearing current. The complete modeling of all components is proposed by considering the couplings between them in a static excitation system. When shaft voltages exceed the dielectric breakdown voltage of the lubricating oil film in journal bearings, electrical discharge current flows through the bearings. This will further reduce the life expectancy of the dielectric gradually. Two different approaches are explained and discussed in detail to keep the shaft voltages within the safe region: a passive filter and a dc–dc converter solution. Both methods along with the initial system are simulated and compared accordingly. Additionally, frequency-domain analysis has been performed for evaluating the compensating solutions. Moreover, experimental tests were carried out on a 200-MVA turbo generator, and results of the suggested passive filter with those of the proposed compensation method are compared. Both experiments and simulations confirm the mentioned issue and show the effectiveness of the proposed compensation approaches in this regard.

[1]  Pramod Agarwal,et al.  Power electronics in hydro electric energy systems – A review , 2014 .

[2]  Andreas Binder,et al.  High-Frequency Induction Machine Modeling for Common Mode Current and Bearing Voltage Calculation , 2014, IEEE Transactions on Industry Applications.

[3]  S. A. Pavelev,et al.  Approach to the development of intelligent systems for controlling the vibration state of turbo-generators based on harmonic wavelet transformation and neural network analysis , 2018 .

[4]  Yeong-Jin Goh,et al.  Linear Method for Diagnosis of Inter-Turn Short Circuits in 3-Phase Induction Motors , 2019, Applied Sciences.

[5]  Jianyun Chai,et al.  A Novel DC Motor Based on Mechanical–Electrical Hybrid Commutation , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[6]  Cai Bochong,et al.  Fault diagnosis of rotor winding inter-turn short circuit for sensorless synchronous generator through screw , 2017 .

[7]  Jalal Nazarzadeh,et al.  Survey on high-frequency models of PWM electric drives for shaft voltage and bearing current analysis , 2017 .

[8]  R. Kazemi Golkhandan,et al.  Suggesting a DC-DC Buck converter for compensating shaft induced voltage and bearing current , 2011, 2011 IEEE Symposium on Industrial Electronics and Applications.

[9]  Manish Kumar,et al.  Design of Passive Common-Mode Attenuation Methods for Inverter-Fed Induction Motor Drive With Reduced Common-Mode Voltage PWM Technique , 2020, IEEE Transactions on Power Electronics.

[11]  Esam H. Ismail,et al.  Ultra Step-Up DC–DC Converter With Reduced Switch Stress , 2010 .

[12]  Abolfazl Vahedi,et al.  A survey of shaft voltage reduction strategies for induction generators in wind energy applications , 2013 .

[13]  Hussain Falih Mahdi,et al.  Investigation of bearing current in a gas turbine generator due to static excitation system , 2013, 2013 IEEE Student Conference on Research and Developement.

[14]  Kamal Al-Haddad,et al.  Impact of Real Air-Gap Nonuniformity on the Electromagnetic Forces of a Large Hydro-Generator , 2018, IEEE Transactions on Industrial Electronics.

[15]  Adam Glowacz,et al.  Recognition of rotor damages in a DC motor using acoustic signals , 2017 .

[16]  James R. Ottewill,et al.  A PCA and Two-Stage Bayesian Sensor Fusion Approach for Diagnosing Electrical and Mechanical Faults in Induction Motors , 2019, IEEE Transactions on Industrial Electronics.

[17]  Masoud Aliakbar Golkar,et al.  A complete excitation-shaft-bearing model to overcome the shaft induced voltage and bearing current , 2011, 2011 2nd Power Electronics, Drive Systems and Technologies Conference.

[18]  Hans-Peter Nee,et al.  Frequency-domain modelling of sub-synchronous torsional interaction of synchronous machines and a high voltage direct current transmission link with line-commutated converters , 2010 .

[19]  J.M. Martinez-Tarifa,et al.  Frequency-Domain Model for Calculation of Voltage Distribution Through Random Wound Coils and Its Interaction With Stray Capacitances , 2008, IEEE Transactions on Energy Conversion.

[20]  Ali Keyhani,et al.  A review of design consideration for Doubly Fed Induction Generator based wind energy system , 2018, Electric Power Systems Research.

[21]  Julio C. Rosas-Caro,et al.  Input-current/output-voltage ripple mitigation in the double dual boost converter , 2018 .

[22]  Alexander Abramovitz,et al.  Analysis and Design of Charge Pump-Assisted High Step-Up Tapped Inductor SEPIC Converter With an “Inductorless” Regenerative Snubber , 2015, IEEE Transactions on Power Electronics.

[23]  K. Beddek,et al.  Study of shaft voltage of a simplified synchronous generator , 2019 .

[24]  Ebrahim Afjei,et al.  New Double-Layer-per-Phase Isolated Switched Reluctance Motor: Concept, Numerical Analysis, and Experimental Confirmation , 2012, IEEE Transactions on Industrial Electronics.

[26]  P. K. Dhara,et al.  An improved dynamic performance of bidirectional SEPIC-Zeta converter based battery energy storage system using adaptive sliding mode control technique , 2018, Electric Power Systems Research.

[27]  Sinisa Djurovic,et al.  Wound rotor induction generator bearing fault modelling and detection using stator current analysis , 2013 .

[28]  Ned Mohan,et al.  On the Causes of Circulating Currents in PWM Drives With Open-End Winding AC Machines , 2013, IEEE Transactions on Industrial Electronics.

[29]  Annette Muetze,et al.  Finite-Element Supported Transmission-Line Models for Calculating High-Frequency Effects in Machine Windings , 2012, IEEE Transactions on Magnetics.

[30]  Adam Glowacz,et al.  Vibration-Based Fault Diagnosis of Commutator Motor , 2018, Shock and Vibration.

[31]  Rajeev Thottappillil,et al.  Modelling an AC motor with high accuracy in a wide frequency range , 2013 .

[32]  Frede Blaabjerg,et al.  High Step-Up Trans-Inverse (Tx−1) DC–DC Converter for the Distributed Generation System , 2016, IEEE Transactions on Industrial Electronics.