Frequency-dependent attenuation reconstruction with an acoustic reflector

Attenuation of ultrasound waves varies with tissue composition, hence its estimation offers great potential for tissue characterization and diagnosis and staging of pathology. We recently proposed a method that allows to spatially reconstruct the distribution of the overall ultrasound attenuation in tissue based on computed tomography, using reflections from a passive acoustic reflector. This requires a standard ultrasound transducer operating in pulse-echo mode and a calibration protocol using water measurements, thus it can be implemented on conventional ultrasound systems with minor adaptations. Herein, we extend this method by additionally estimating and imaging the frequency-dependent nature of local ultrasound attenuation for the first time. Spatial distributions of attenuation coefficient and exponent are reconstructed, enabling an elaborate and expressive tissue-specific characterization. With simulations, we demonstrate that our proposed method yields a low reconstruction error of 0.04 dB/cm at 1 MHz for attenuation coefficient and 0.08 for the frequency exponent. With tissue-mimicking phantoms and ex-vivo bovine muscle samples, a high reconstruction contrast as well as reproducibility are demonstrated. Attenuation exponents of a gelatin-cellulose mixture and an ex-vivo bovine muscle sample were found to be, respectively, 1.4 and 0.5 on average, consistently from different images of their heterogeneous compositions. Such frequency-dependent parametrization could enable novel imaging and diagnostic techniques, as well as facilitate attenuation compensation of other ultrasound-based imaging techniques.

[1]  D. Rubens,et al.  Shear wave dispersion measures liver steatosis. , 2012, Ultrasound in medicine & biology.

[2]  Sheng-Wen Huang,et al.  Ultrasonic computed tomography reconstruction of the attenuation coefficient using a linear array. , 2005, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[3]  M. Fink,et al.  Shear modulus imaging with 2-D transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Ping Gong,et al.  System-Independent Ultrasound Attenuation Coefficient Estimation Using Spectra Normalization , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[5]  F. Dunn,et al.  Compilation of empirical ultrasonic properties of mammalian tissues. II. , 1980, The Journal of the Acoustical Society of America.

[6]  M Fink,et al.  Measurement of viscoelastic properties of homogeneous soft solid using transient elastography: An inverse problem approach , 2004 .

[7]  Bilal H. Malik,et al.  Quantitative transmission ultrasound tomography: Imaging and performance characteristics , 2018, Medical physics.

[8]  Roberto Lavarello,et al.  Regularized Spectral Log Difference Technique for Ultrasonic Attenuation Imaging , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Orcun Goksel,et al.  Speed-of-Sound Imaging Based on Reflector Delineation , 2019, IEEE Transactions on Biomedical Engineering.

[10]  James F. Greenleaf,et al.  Application of Attenuation Measuring Ultrasound Shearwave Elastography in 8 post-transplant liver patients , 2014, 2014 IEEE International Ultrasonics Symposium.

[11]  N. Duric,et al.  Detection of breast cancer with ultrasound tomography: first results with the Computed Ultrasound Risk Evaluation (CURE) prototype. , 2007, Medical physics.

[12]  Robert Rohling,et al.  SWTV-ACE: Spatially Weighted Regularization Based Attenuation Coefficient Estimation Method for Hepatic Steatosis Detection , 2019, MICCAI.

[13]  Robert Rohling,et al.  Tracked “Pick-Up” Ultrasound for Robot-Assisted Minimally Invasive Surgery , 2016, IEEE Transactions on Biomedical Engineering.

[14]  D. Shanno Conditioning of Quasi-Newton Methods for Function Minimization , 1970 .

[15]  Orcun Goksel,et al.  Speed-of-sound imaging using diverging waves , 2019, International Journal of Computer Assisted Radiology and Surgery.

[16]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[17]  Hassan Rivaz,et al.  Low Variance Estimation of Backscatter Quantitative Ultrasound Parameters Using Dynamic Programming , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[18]  Orcun Goksel,et al.  Attenuation Imaging with Pulse-Echo Ultrasound Based on an Acoustic Reflector , 2019, MICCAI.

[19]  Mila Nikolova,et al.  Efficient Minimization Methods of Mixed l2-l1 and l1-l1 Norms for Image Restoration , 2005, SIAM J. Sci. Comput..

[20]  Richard Rau,et al.  3D functional ultrasound imaging of pigeons , 2018, NeuroImage.

[21]  Orcun Goksel,et al.  Speed of sound ultrasound: a pilot study on a novel technique to identify sarcopenia in seniors , 2018, European Radiology.

[22]  Neb Duric,et al.  Breast imaging using waveform attenuation tomography , 2017, Medical Imaging.

[23]  Orcun Goksel,et al.  Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening? , 2018, European Radiology.

[24]  C. R. Hill,et al.  Acoustic properties of normal and cancerous human liver-I. Dependence on pathological condition. , 1981, Ultrasound in medicine & biology.

[25]  Tadashi Yamaguchi,et al.  Frequency dependence of attenuation and backscatter coefficient of ex vivo human lymphedema dermis , 2019, Journal of Medical Ultrasonics.

[26]  Orcun Goksel,et al.  Acoustoelasticity Analysis of Shear Waves for Nonlinear Biomechanical Characterization of Oil-Gelatin Phantoms , 2019, 2019 IEEE International Ultrasonics Symposium (IUS).

[27]  D. Goldfarb A family of variable-metric methods derived by variational means , 1970 .

[28]  Orcun Goksel,et al.  Nonlinear Characterization of Tissue Viscoelasticity With Acoustoelastic Attenuation of Shear Waves , 2022, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[29]  Andrew Webb,et al.  Introduction to Medical Imaging: Physics, Engineering and Clinical Applications , 2010 .

[30]  Thomas L. Szabo,et al.  Diagnostic Ultrasound Imaging: Inside Out , 2004 .

[31]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[32]  Haim Azhari,et al.  A Method for Characterization of Tissue Elastic Properties Combining Ultrasonic Computed Tomography With Elastography , 2010, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[33]  Orcun Goksel,et al.  Hand-Held Sound-Speed Imaging Based on Ultrasound Reflector Delineation , 2016, MICCAI.

[34]  Orcun Goksel,et al.  Spatial domain reconstruction for imaging speed-of-sound with pulse-echo ultrasound: simulation and in vivo study , 2018, Physics in medicine and biology.

[35]  Xosé Luís Deán-Ben,et al.  Transmission–reflection optoacoustic ultrasound (TROPUS) computed tomography of small animals , 2019, Light, science & applications.

[36]  Robert Rohling,et al.  Attenuation Coefficient Estimation of Normal Placentas. , 2019, Ultrasound in medicine & biology.

[37]  C R Hill,et al.  Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature. , 1979, Ultrasound in medicine & biology.

[38]  Orcun Goksel,et al.  Ultrasound Aberration Correction based on Local Speed-of-Sound Map Estimation , 2019, 2019 IEEE International Ultrasonics Symposium (IUS).

[39]  Guy Cloutier,et al.  Construction of adaptively regularized parametric maps for quantitative ultrasound imaging , 2019, 2019 IEEE International Ultrasonics Symposium (IUS).

[40]  R. Fletcher,et al.  A New Approach to Variable Metric Algorithms , 1970, Comput. J..

[41]  C. G. Broyden The Convergence of a Class of Double-rank Minimization Algorithms 1. General Considerations , 1970 .

[42]  Orcun Goksel,et al.  Deep Variational Networks with Exponential Weighting for Learning Computed Tomography , 2019, MICCAI.

[43]  Pengfei Song,et al.  Validation of shear wave elastography in skeletal muscle. , 2013, Journal of biomechanics.

[44]  Orcun Goksel,et al.  Image Reconstruction via Variational Network for Real-Time Hand-Held Sound-Speed Imaging , 2018, MLMIR@MICCAI.

[45]  Sheng-Wen Huang,et al.  P3G-9 Reconstruction of Ultrasonic Sound Velocity and Attenuation Coefficient Using Linear Arrays: Clinical Assessment , 2006, 2006 IEEE Ultrasonics Symposium.