Variability and Standardization of Quantitative Imaging
暂无分享,去创建一个
S. Aoki | Y. Ohno | S. Fujita | A. Hagiwara
[1] E. Purcell,et al. Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments , 1954 .
[2] S. Meiboom,et al. Modified Spin‐Echo Method for Measuring Nuclear Relaxation Times , 1958 .
[3] A. Beckett,et al. AKUFO AND IBARAPA. , 1965, Lancet.
[4] D. Look,et al. Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .
[5] J. Hanley,et al. The effect of measuring error on the results of therapeutic trials in advanced cancer , 1976, Cancer.
[6] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[7] S. Riederer,et al. Optimizing the precision in T1 relaxation estimation using limited flip angles , 1987, Magnetic resonance in medicine.
[8] G. Barker,et al. Semiautomated quality assurance for quantitative magnetic resonance imaging. , 1992, Magnetic resonance imaging.
[9] P. Tofts,et al. Ni-DTPA doped agarose gel--a phantom material for Gd-DTPA enhancement measurements. , 1993, Magnetic resonance imaging.
[10] C. Stewart‐Amidei. Profiles , 1995 .
[11] D. Altman,et al. Statistics Notes: Measurement error and correlation coefficients , 1996, BMJ.
[12] A. Nevill,et al. Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science. , 1997, British journal of sports medicine.
[13] M. Tanemura,et al. Quantitative assessment of the spatial distribution of low attenuation areas on X-ray CT using texture analysis in patients with chronic pulmonary emphysema. , 1997, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.
[14] R. Edelman,et al. A Phantom for diffusion‐weighted imaging of acute stroke , 1998, Journal of magnetic resonance imaging : JMRI.
[15] M. Knopp,et al. Estimating kinetic parameters from dynamic contrast‐enhanced t1‐weighted MRI of a diffusable tracer: Standardized quantities and symbols , 1999, Journal of magnetic resonance imaging : JMRI.
[16] A. MacKay,et al. Are mono‐exponential fits to a few echoes sufficient to determine T2 relaxation for in vivo human brain? , 1999, Magnetic resonance in medicine.
[17] D. Hoult. The principle of reciprocity in signal strength calculations—a mathematical guide , 2000 .
[18] J. Fischer,et al. Intrarater and interrater reliability of the MS functional composite outcome measure , 2000, Neurology.
[19] R M Harrison,et al. Quality assurance for MRI: practical experience. , 2000, The British journal of radiology.
[20] D. DeMets,et al. Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework , 2001, Clinical pharmacology and therapeutics.
[21] P. Paré,et al. Quantitative assessment of airway remodeling using high-resolution CT. , 2002, Chest.
[22] A. Pfefferbaum,et al. Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain , 2003, Journal of magnetic resonance imaging : JMRI.
[23] H. Potter,et al. T2 quantitation of articular cartilage at 1.5 T , 2003, Journal of magnetic resonance imaging : JMRI.
[24] M. Leach,et al. Developing a quality control protocol for diffusion imaging on a clinical MRI system. , 2004, Physics in medicine and biology.
[25] R. Constable,et al. Measurement and correction of transmitter and receiver induced nonuniformities in vivo , 2005, Magnetic resonance in medicine.
[26] T. Peters,et al. High‐resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2 , 2005, Magnetic resonance in medicine.
[27] Harold L Kundel,et al. History of research in medical image perception. , 2006, Journal of the American College of Radiology : JACR.
[28] M. Hasegawa,et al. Airflow limitation and airway dimensions in chronic obstructive pulmonary disease. , 2006, American journal of respiratory and critical care medicine.
[29] M. Symms,et al. A simple correction for B1 field errors in magnetization transfer ratio measurements. , 2006, Magnetic resonance imaging.
[30] D. Xu,et al. Nodule management protocol of the NELSON randomised lung cancer screening trial. , 2006, Lung cancer.
[31] S. Nelson,et al. Measurement of in vivo multi-component T2 relaxation times for brain tissue using multi-slice T2 prep at 1.5 and 3 T. , 2006, Magnetic resonance imaging.
[32] G. Wright,et al. Rapid high‐resolution T1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity , 2006, Magnetic resonance in medicine.
[33] G. Barker,et al. Sources of variation in multi-centre brain MTR histogram studies: body-coil transmission eliminates inter-centre differences , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.
[34] E. V. van Beek,et al. The Lung Image Database Consortium (LIDC): a comparison of different size metrics for pulmonary nodule measurements. , 2007, Academic radiology.
[35] K. Uğurbil,et al. Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo , 2007, Magnetic resonance in medicine.
[36] L. Turnbull,et al. Repeatability of echo-planar-based diffusion measurements of the human prostate at 3 T. , 2007, Magnetic resonance imaging.
[37] David Bonekamp,et al. Diffusion tensor imaging in children and adolescents: Reproducibility, hemispheric, and age-related differences , 2007, NeuroImage.
[38] P. Lundberg,et al. Rapid magnetic resonance quantification on the brain: Optimization for clinical usage , 2008, Magnetic resonance in medicine.
[39] H. Kauczor,et al. Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.
[40] Kei Yamada,et al. Variability in absolute apparent diffusion coefficient values across different platforms may be substantial: a multivendor, multi-institutional comparison study. , 2008, Radiology.
[41] D. Barboriak,et al. Repeatability of quantitative parameters derived from diffusion tensor imaging in patients with glioblastoma multiforme , 2009, Journal of magnetic resonance imaging : JMRI.
[42] P. Choyke,et al. Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. , 2009, Neoplasia.
[43] E. Merkle,et al. Short- and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. , 2009, Radiology.
[44] S. Lam,et al. New and current clinical imaging techniques to study chronic obstructive pulmonary disease. , 2009, American journal of respiratory and critical care medicine.
[45] T. Chenevert,et al. Diffusion-weighted MRI for assessment of early cancer treatment response. , 2010, Current pharmaceutical biotechnology.
[46] J. Remy,et al. Thoracic applications of dual energy. , 2010, Radiologic clinics of North America.
[47] E. Weibel,et al. American Thoracic Society Documents An Official Research Policy Statement of the American Thoracic Society/European Respiratory Society: Standards for Quantitative Assessment of Lung Structure , 2010 .
[48] Raúl San José Estépar,et al. Pulmonary hypertension and computed tomography measurement of small pulmonary vessels in severe emphysema. , 2010, American journal of respiratory and critical care medicine.
[49] Sang Joon Park,et al. Chronic obstructive pulmonary disease: quantitative and visual ventilation pattern analysis at xenon ventilation CT performed by using a dual-energy technique. , 2010, Radiology.
[50] D. Sullivan,et al. A collaborative enterprise for multi-stakeholder participation in the advancement of quantitative imaging. , 2011, Radiology.
[51] D. Collins,et al. Multicentre imaging measurements for oncology and in the brain. , 2011, The British journal of radiology.
[52] C. Meyer,et al. Diffusion coefficient measurement using a temperature‐controlled fluid for quality control in multicenter studies , 2011, Journal of magnetic resonance imaging : JMRI.
[53] G. McLennan,et al. Quantitative imaging test approval and biomarker qualification: interrelated but distinct activities. , 2011, Radiology.
[54] C. Gatsonis,et al. Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening , 2012 .
[55] H. Kauczor,et al. Treatment Monitoring in Gliomas: Comparison of Dynamic Susceptibility-Weighted Contrast-Enhanced and Spectroscopic MRI Techniques for Identifying Treatment Failure , 2011, Investigative radiology.
[56] A. Hrõbjartsson,et al. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. , 2011, Journal of clinical epidemiology.
[57] J. Bussink,et al. Diffusion-weighted MR imaging in liver metastases of colorectal cancer: reproducibility and biological validation , 2013, European Radiology.
[58] R. Deichmann,et al. Correction of systematic errors in quantitative proton density mapping , 2012, Magnetic resonance in medicine.
[59] M. Tanter,et al. Measurement of pulsatile motion with millisecond resolution by MRI , 2012, Magnetic resonance in medicine.
[60] Ali O. Farooqi,et al. Lung cancers diagnosed at annual CT screening: volume doubling times. , 2012, Radiology.
[61] K. Murase,et al. Quantitative bronchial luminal volumetric assessment of pulmonary function loss by thin-section MDCT in pulmonary emphysema patients. , 2012, European journal of radiology.
[62] Meilan K. Han,et al. Pulmonary arterial enlargement and acute exacerbations of COPD. , 2012, The New England journal of medicine.
[63] Y. Ohno,et al. Three-dimensional airway lumen volumetry: comparison with bronchial wall area and parenchymal densitometry in assessment of airway obstruction in pulmonary emphysema. , 2012, The British journal of radiology.
[64] A. Dirksen,et al. CT screening for lung cancer brings forward early disease. The randomised Danish Lung Cancer Screening Trial: status after five annual screening rounds with low-dose CT , 2012, Thorax.
[65] H. Huisman,et al. Interpatient variation in normal peripheral zone apparent diffusion coefficient: effect on the prediction of prostate cancer aggressiveness. , 2012, Radiology.
[66] Maud Marchal,et al. An anthropomorphic polyvinyl alcohol brain phantom based on Colin27 for use in multimodal imaging. , 2012, Medical physics.
[67] R. Boubertakh,et al. In vitro and in vivo repeatability of abdominal diffusion-weighted MRI. , 2012, The British journal of radiology.
[68] T. Mizoue,et al. A decrease in lung cancer mortality following the introduction of low-dose chest CT screening in Hitachi, Japan. , 2012, Lung cancer.
[69] M. Markey,et al. Differentiating tumor recurrence from treatment necrosis: a review of neuro-oncologic imaging strategies. , 2013, Neuro-oncology.
[70] J. Goldin. Computed Tomography as a Biomarker in Clinical Trials Imaging , 2013, Journal of thoracic imaging.
[71] J. Duerk,et al. Magnetic Resonance Fingerprinting , 2013, Nature.
[72] J. Remy,et al. Thoracic Applications of Dual Energy , 2014, Seminars in Respiratory and Critical Care Medicine.
[73] P. Lambin,et al. Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation , 2014, PloS one.
[74] H. Merisaari,et al. Optimization of b‐value distribution for biexponential diffusion‐weighted MR imaging of normal prostate , 2014, Journal of magnetic resonance imaging : JMRI.
[75] H. Kauczor,et al. Radiation dose reduction in chest CT--review of available options. , 2014, European journal of radiology.
[76] M. E. Moseley,et al. MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain , 2014, NeuroImage.
[77] A. Leung,et al. Prognostic importance of volumetric measurements in stage I lung adenocarcinoma. , 2014, Radiology.
[78] A. Padhani,et al. Apparent diffusion coefficient measurements as very early predictive markers of response to chemotherapy in hepatic metastasis: A preliminary investigation of reproducibility and diagnostic value , 2014, Journal of magnetic resonance imaging : JMRI.
[79] Binsheng Zhao,et al. Comparison of 1D, 2D, and 3D nodule sizing methods by radiologists for spherical and complex nodules on thoracic CT phantom images. , 2014, Academic radiology.
[80] K. Fong,et al. Biomarkers of progression of chronic obstructive pulmonary disease (COPD). , 2014, Journal of thoracic disease.
[81] T. Ebbers,et al. Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS , 2014, Journal of Cardiovascular Magnetic Resonance.
[82] P. Börnert,et al. Ventricular B1+ perturbation at 7 T – real effect or measurement artifact? , 2014, NMR in biomedicine.
[83] S. Matsumoto,et al. Iterative reconstruction technique vs filter back projection: utility for quantitative bronchial assessment on low-dose thin-section MDCT in patients with/without chronic obstructive pulmonary disease , 2014, European Radiology.
[84] H. D. de Koning,et al. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers. , 2014, The Lancet. Oncology.
[85] T. Helbich,et al. Improved Diagnostic Accuracy With Multiparametric Magnetic Resonance Imaging of the Breast Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging, Diffusion-Weighted Imaging, and 3-Dimensional Proton Magnetic Resonance Spectroscopic Imaging , 2014, Investigative radiology.
[86] M. Schluchter,et al. Simultaneous T1 and T2 Brain Relaxometry in Asymptomatic Volunteers Using Magnetic Resonance Fingerprinting , 2015, Tomography.
[87] P. Hahn,et al. Body MR Imaging: Artifacts, k-Space, and Solutions. , 2015, Radiographics : a review publication of the Radiological Society of North America, Inc.
[88] Olivier Gevaert,et al. Core samples for radiomics features that are insensitive to tumor segmentation: method and pilot study using CT images of hepatocellular carcinoma , 2015, Journal of medical imaging.
[89] A. Field,et al. Mean apparent diffusion coefficient values in defining radiotherapy planning target volumes in glioblastoma. , 2015, Quantitative imaging in medicine and surgery.
[90] M. Griswold,et al. MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout , 2015, Magnetic resonance in medicine.
[91] D. Lynch,et al. CT staging and monitoring of fibrotic interstitial lung diseases in clinical practice and treatment trials: a position paper from the Fleischner Society. , 2015, The Lancet. Respiratory medicine.
[92] Kyle J Myers,et al. Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons , 2014, Statistical methods in medical research.
[93] T. Scheenen,et al. Multiparametric Magnetic Resonance Imaging in Prostate Cancer Management: Current Status and Future Perspectives , 2015, Investigative radiology.
[94] N. Petrick,et al. Statistical analysis of lung nodule volume measurements with CT in a large-scale phantom study. , 2015, Medical physics.
[95] M. Sahraian,et al. Classification algorithms with multi-modal data fusion could accurately distinguish neuromyelitis optica from multiple sclerosis , 2015, NeuroImage: Clinical.
[96] P. Marsden,et al. False Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review , 2015, PloS one.
[97] N. Obuchowski,et al. Introduction to metrology series , 2015, Statistical methods in medical research.
[98] Christine L. Tardif,et al. On the accuracy of T1 mapping: Searching for common ground , 2015, Magnetic resonance in medicine.
[99] Erich P Huang,et al. Meta-analysis of the technical performance of an imaging procedure: Guidelines and statistical methodology , 2015, Statistical methods in medical research.
[100] Mithat Gönen,et al. Quantitative imaging biomarkers: A review of statistical methods for technical performance assessment , 2015, Statistical methods in medical research.
[101] M. Scorsetti,et al. Long-Term Follow-up Results of the DANTE Trial, a Randomized Study of Lung Cancer Screening with Spiral Computed Tomography. , 2015, American journal of respiratory and critical care medicine.
[102] S. Armato,et al. Role of the Quantitative Imaging Biomarker Alliance in optimizing CT for the evaluation of lung cancer screen-detected nodules. , 2015, Journal of the American College of Radiology : JACR.
[103] Jinzhong Yang,et al. Measuring Computed Tomography Scanner Variability of Radiomics Features , 2015, Investigative radiology.
[104] J. Alger,et al. Between-Scanner and Between-Visit Variation in Normal White Matter Apparent Diffusion Coefficient Values in the Setting of a Multi-Center Clinical Trial , 2016, Clinical Neuroradiology.
[105] Fei Yang,et al. Quantitative radiomics: impact of stochastic effects on textural feature analysis implies the need for standards , 2015, Journal of medical imaging.
[106] D. Auer,et al. Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain , 2015, NMR in biomedicine.
[107] H. Merisaari,et al. Evaluation of different mathematical models for diffusion‐weighted imaging of normal prostate and prostate cancer using high b‐values: A repeatability study , 2015, Magnetic resonance in medicine.
[108] H. Barnhart,et al. The emerging science of quantitative imaging biomarkers terminology and definitions for scientific studies and regulatory submissions , 2015, Statistical methods in medical research.
[109] Robert J. Nordstrom,et al. The Quantitative Imaging Network in Precision Medicine , 2016, Tomography.
[110] Stephen J Sawiak,et al. MR fingerprinting with simultaneous B1 estimation , 2015, Magnetic resonance in medicine.
[111] Steffen Löck,et al. Image biomarker standardisation initiative , 2016 .
[112] W. Block,et al. Rapid multicomponent relaxometry in steady state with correction of magnetization transfer effects , 2016, Magnetic resonance in medicine.
[113] Wei Huang,et al. Demonstration of nonlinearity bias in the measurement of the apparent diffusion coefficient in multicenter trials , 2016, Magnetic resonance in medicine.
[114] W. Tsai,et al. Reproducibility of radiomics for deciphering tumor phenotype with imaging , 2016, Scientific Reports.
[115] Yong Chen,et al. MR Fingerprinting for Rapid Quantitative Abdominal Imaging. , 2016, Radiology.
[116] Lubomir M. Hadjiiski,et al. Radiomics of Lung Nodules: A Multi-Institutional Study of Robustness and Agreement of Quantitative Imaging Features , 2016, Tomography.
[117] M. Harisinghani,et al. A practical primer on PI-RADS version 2: a pictorial essay , 2016, Abdominal Radiology.
[118] Nicholas Petrick,et al. Statistical Issues in Testing Conformance with the Quantitative Imaging Biomarker Alliance (QIBA) Profile Claims. , 2016, Academic radiology.
[119] M. Esposito,et al. Quality assurance multicenter comparison of different MR scanners for quantitative diffusion‐weighted imaging , 2016, Journal of magnetic resonance imaging : JMRI.
[120] Keith Wachowicz,et al. Analytical corrections of banding artifacts in driven equilibrium single pulse observation of T2 (DESPOT2) , 2016, Magnetic resonance in medicine.
[121] Kilian M. Pohl,et al. Harmonizing DTI measurements across scanners to examine the development of white matter microstructure in 803 adolescents of the NCANDA study , 2016, NeuroImage.
[122] P. Lundberg,et al. Modeling the Presence of Myelin and Edema in the Brain Based on Multi-Parametric Quantitative MRI , 2016, Front. Neurol..
[123] M. Miquel,et al. Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility. , 2016, World journal of radiology.
[124] N. Hylton,et al. Design of a breast phantom for quantitative MRI , 2016, Journal of magnetic resonance imaging : JMRI.
[125] Terry K Koo,et al. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. , 2016, Journal Chiropractic Medicine.
[126] D. Lynch,et al. Pulmonary CT and MRI phenotypes that help explain chronic pulmonary obstruction disease pathophysiology and outcomes , 2016, Journal of magnetic resonance imaging : JMRI.
[127] Paul Kinahan,et al. Radiomics: Images Are More than Pictures, They Are Data , 2015, Radiology.
[128] Y. Ohno,et al. Comparative evaluation of newly developed model-based and commercially available hybrid-type iterative reconstruction methods and filter back projection method in terms of accuracy of computer-aided volumetry (CADv) for low-dose CT protocols in phantom study. , 2016, European journal of radiology.
[129] A. MacKay,et al. Measuring water content using T2 relaxation at 3T: Phantom validations and simulations. , 2016, Magnetic resonance imaging.
[130] Ken E Sakaie,et al. Quantitative quality assurance in a multicenter HARDI clinical trial at 3T. , 2017, Magnetic resonance imaging.
[131] D. Lynch,et al. Securing safe and informative thoracic CT examinations-Progress of radiation dose reduction techniques. , 2017, European journal of radiology.
[132] O. Abe,et al. SyMRI of the Brain , 2017, Investigative radiology.
[133] P. Lakhani,et al. Deep Learning at Chest Radiography: Automated Classification of Pulmonary Tuberculosis by Using Convolutional Neural Networks. , 2017, Radiology.
[134] Lawrence L. Wald,et al. 3D MR fingerprinting with accelerated stack-of-spirals and hybrid sliding-window and GRAPPA reconstruction , 2017, NeuroImage.
[135] O. Abe,et al. Analysis of White Matter Damage in Patients with Multiple Sclerosis via a Novel In Vivo MR Method for Measuring Myelin, Axons, and G-Ratio , 2017, American Journal of Neuroradiology.
[136] Ragini Verma,et al. Harmonization of multi-site diffusion tensor imaging data , 2017, NeuroImage.
[137] Teaching Neuroimages: Obscured Cerebral Infarction on MRI , 2017, Clinical Neuroradiology.
[138] J. Duerk,et al. MR fingerprinting using the quick echo splitting NMR imaging technique , 2017, Magnetic resonance in medicine.
[139] M. Ladd,et al. Temperature and concentration calibration of aqueous polyvinylpyrrolidone (PVP) solutions for isotropic diffusion MRI phantoms , 2017, PloS one.
[140] D. Lynch,et al. Standardizing CT lung density measure across scanner manufacturers , 2017, Medical physics.
[141] Hanzhang Lu,et al. Multiparametric estimation of brain hemodynamics with MR fingerprinting ASL , 2017, Magnetic resonance in medicine.
[142] K. Kumamaru,et al. Utility of a Multiparametric Quantitative MRI Model That Assesses Myelin and Edema for Evaluating Plaques, Periplaque White Matter, and Normal-Appearing White Matter in Patients with Multiple Sclerosis: A Feasibility Study , 2017, American Journal of Neuroradiology.
[143] F. Fennessy,et al. Multiparametric Magnetic Resonance Imaging of the Prostate , 2017, Investigative radiology.
[144] Jesse I. Hamilton,et al. MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density , 2017, Magnetic resonance in medicine.
[145] M. Griswold,et al. Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom , 2017, Magnetic resonance in medicine.
[146] Thomas Frauenfelder,et al. Deep Learning in Mammography: Diagnostic Accuracy of a Multipurpose Image Analysis Software in the Detection of Breast Cancer , 2017, Investigative radiology.
[147] Mara Cercignani,et al. Brain microstructure by multi-modal MRI: Is the whole greater than the sum of its parts? , 2017, NeuroImage.
[148] J. E. van Timmeren,et al. Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study , 2017, Acta oncologica.
[149] P. Lambin,et al. Radial gradient and radial deviation radiomic features from pre-surgical CT scans are associated with survival among lung adenocarcinoma patients , 2017, Oncotarget.
[150] Geoffrey G. Zhang,et al. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels , 2017, Medical physics.
[151] Y. Ohno,et al. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers. , 2017, European journal of radiology.
[152] P. Lambin,et al. Radiomics: the bridge between medical imaging and personalized medicine , 2017, Nature Reviews Clinical Oncology.
[153] S. Aoki,et al. The Advantage of Synthetic MRI for the Visualization of Anterior Temporal Pole Lesions on Double Inversion Recovery (DIR), Phase-sensitive Inversion Recovery (PSIR), and Myelin Images in a Patient with CADASIL , 2017, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[154] M. Kataoka,et al. Impact of the Number of Iterations in Compressed Sensing Reconstruction on Ultrafast Dynamic Contrast-enhanced Breast MR Imaging , 2018, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[155] So Mi Lee,et al. Age-Related Changes in Tissue Value Properties in Children: Simultaneous Quantification of Relaxation Times and Proton Density Using Synthetic Magnetic Resonance Imaging , 2017, Investigative radiology.
[156] Frank Thiele,et al. Clinical Evaluation of a Multiparametric Deep Learning Model for Glioblastoma Segmentation Using Heterogeneous Magnetic Resonance Imaging Data From Clinical Routine , 2018, Investigative radiology.
[157] Young Han Lee,et al. Quantitative T2 Mapping of Knee Cartilage: Comparison between the Synthetic MR Imaging and the CPMG Sequence , 2018, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[158] S. Aoki,et al. Reduced visualization of cerebral infarction on diffusion-weighted images with short diffusion times , 2018, Neuroradiology.
[159] S. Aoki,et al. Spatial Restriction within Intracranial Epidermoid Cysts Observed Using Short Diffusion-time Diffusion-weighted Imaging , 2017, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[160] S. Park,et al. Methodologic Guide for Evaluating Clinical Performance and Effect of Artificial Intelligence Technology for Medical Diagnosis and Prediction. , 2018, Radiology.
[161] Kunihiro Yagihashi,et al. Quantitative CT Evaluation of Small Pulmonary Vessels in Patients with Acute Pulmonary Embolism. , 2018, Academic radiology.
[162] R. Gillies,et al. Repeatability and Reproducibility of Radiomic Features: A Systematic Review , 2018, International journal of radiation oncology, biology, physics.
[163] J. Canales‐Vázquez,et al. Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters. , 2018, Radiology.
[164] J. E. van Timmeren,et al. Tracking tumor biology with radiomics: A systematic review utilizing a radiomics quality score. , 2018, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[165] Geoffrey G. Zhang,et al. Voxel size and gray level normalization of CT radiomic features in lung cancer , 2018, Scientific Reports.
[166] Jin Keun Seo,et al. Deep learning for undersampled MRI reconstruction , 2017, Physics in medicine and biology.
[167] C. Jack,et al. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom , 2018, Magnetic resonance in medicine.
[168] M. McMahon,et al. Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF) , 2017, Magnetic resonance in medicine.
[169] Daniel K Sodickson,et al. Exploring the sensitivity of magnetic resonance fingerprinting to motion. , 2018, Magnetic resonance imaging.
[170] S. Aoki,et al. Synthetic MRI of the knee: new perspectives in musculoskeletal imaging and possible applications for the assessment of bone marrow disorders. , 2018, The British journal of radiology.
[171] W. Stiller. Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview. , 2018, European journal of radiology.
[172] Travis B. Smith,et al. Multi‐parametric T2* magnetic resonance fingerprinting using variable echo times , 2018, NMR in biomedicine.
[173] T. Yankeelov,et al. Repeatability, reproducibility, and accuracy of quantitative mri of the breast in the community radiology setting , 2018, Journal of magnetic resonance imaging : JMRI.
[174] T. Helbich,et al. Diffusion-Weighted Imaging With Apparent Diffusion Coefficient Mapping for Breast Cancer Detection as a Stand-Alone Parameter: Comparison With Dynamic Contrast-Enhanced and Multiparametric Magnetic Resonance Imaging , 2018, Investigative radiology.
[175] A. Manoliu,et al. Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate , 2017, Investigative radiology.
[176] Russell T. Shinohara,et al. Harmonization of cortical thickness measurements across scanners and sites , 2017, NeuroImage.
[177] L. Schad,et al. A novel 3D printed mechanical actuator using centrifugal force for magnetic resonance elastography: Initial results in an anthropomorphic prostate phantom , 2018, PloS one.
[178] S. Punwani,et al. Fat fraction mapping using magnetic resonance imaging: insight into pathophysiology. , 2017, The British journal of radiology.
[179] S. Aoki,et al. Automated brain tissue and myelin volumetry based on quantitative MR imaging with various in-plane resolutions. , 2017, Journal of neuroradiology. Journal de neuroradiologie.
[180] S. Aoki,et al. Application of Quantitative Microstructural MR Imaging with Atlas-based Analysis for the Spinal Cord in Cervical Spondylotic Myelopathy , 2018, Scientific Reports.
[181] Els Fieremans,et al. Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook , 2018, NeuroImage.
[182] Anthony E Samir,et al. Essentials of Statistical Methods for Assessing Reliability and Agreement in Quantitative Imaging. , 2017, Academic radiology.
[183] O. Abe,et al. Changes in the ADC of diffusion-weighted MRI with the oscillating gradient spin-echo (OGSE) sequence due to differences in substrate viscosities , 2018, Japanese Journal of Radiology.
[184] Tobias Kober,et al. Magnetization transfer in magnetic resonance fingerprinting , 2019, Magnetic resonance in medicine.
[185] S. Aoki,et al. Gray Matter Alterations in Early and Late Relapsing-Remitting Multiple Sclerosis Evaluated with Synthetic Quantitative Magnetic Resonance Imaging , 2019, Scientific Reports.
[186] A Vamvakas,et al. Imaging biomarker analysis of advanced multiparametric MRI for glioma grading. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.
[187] M. Nittka,et al. Comprehensive Evaluation of B1+-corrected FISP-based Magnetic Resonance Fingerprinting: Accuracy, Repeatability and Reproducibility of T1 and T2 Relaxation Times for ISMRM/NIST System Phantom and Volunteers , 2019, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[188] Saori C. Tanaka,et al. Harmonization of resting-state functional MRI data across multiple imaging sites via the separation of site differences into sampling bias and measurement bias , 2018, bioRxiv.
[189] B. Baessler,et al. Robustness and Reproducibility of Radiomics in Magnetic Resonance Imaging: A Phantom Study , 2019, Investigative radiology.
[190] T. Kubo. Vendor free basics of radiation dose reduction techniques for CT. , 2019, European journal of radiology.
[191] J Wrobel,et al. Intensity warping for multisite MRI harmonization , 2019, NeuroImage.
[192] Evgeny Burnaev,et al. Bayesian Generative Models for Knowledge Transfer in MRI Semantic Segmentation Problems , 2019, Front. Neurosci..
[193] Y. Ohno,et al. Effects of acquisition method and reconstruction algorithm for CT number measurement on standard-dose CT and reduced-dose CT: a QIBA phantom study , 2019, Japanese Journal of Radiology.
[194] Kourosh Jafari-Khouzani,et al. Effect of Region of Interest Size on the Repeatability of Quantitative Brain Imaging Biomarkers , 2019, IEEE Transactions on Biomedical Engineering.
[195] Yuta Kobayashi,et al. Diffusion-weighting Caused by Spoiler Gradients in the Fast Imaging with Steady-state Precession Sequence May Lead to Inaccurate T2 Measurements in MR Fingerprinting , 2018, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[196] Yun Jiang,et al. Magnetic resonance fingerprinting: a technical review , 2018, Magnetic resonance in medicine.
[197] N. Hattori,et al. Improving the Quality of Synthetic FLAIR Images with Deep Learning Using a Conditional Generative Adversarial Network for Pixel-by-Pixel Image Translation , 2019, American Journal of Neuroradiology.
[198] Pew-Thian Yap,et al. Multi-Site Harmonization of Diffusion MRI Data via Method of Moments , 2019, IEEE Transactions on Medical Imaging.
[199] O. Abe,et al. Choroid plexus cysts analyzed using diffusion-weighted imaging with short diffusion-time. , 2019, Magnetic resonance imaging.
[200] Aaron Carass,et al. DeepHarmony: A deep learning approach to contrast harmonization across scanner changes. , 2019, Magnetic resonance imaging.
[201] Andreas Maier,et al. Magnetic Resonance Fingerprinting Reconstruction Using Recurrent Neural Networks , 2019, GMDS.
[202] P. Lambin,et al. Stability of radiomics features in apparent diffusion coefficient maps from a multi-centre test-retest trial , 2019, Scientific Reports.
[203] M. Nittka,et al. Reproducibility and Repeatability of MR Fingerprinting Relaxometry in the Human Brain. , 2019, Radiology.
[204] M. Kitajima,et al. Deep Learning Based Noise Reduction for Brain MR Imaging: Tests on Phantoms and Healthy Volunteers , 2019, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[205] Holden H. Wu,et al. Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs , 2019, Journal of magnetic resonance imaging : JMRI.
[206] T. Helbich,et al. Impact of Machine Learning With Multiparametric Magnetic Resonance Imaging of the Breast for Early Prediction of Response to Neoadjuvant Chemotherapy and Survival Outcomes in Breast Cancer Patients , 2019, Investigative radiology.
[207] M. Schluchter,et al. Targeted Biopsy Validation of Peripheral Zone Prostate Cancer Characterization With Magnetic Resonance Fingerprinting and Diffusion Mapping. , 2019, Investigative radiology.
[208] K. Kumamaru,et al. Diagnostic accuracy of 3D deep-learning-based fully automated estimation of patient-level minimum fractional flow reserve from coronary computed tomography angiography. , 2019, European heart journal cardiovascular Imaging.
[209] S. Aoki,et al. Convolutional neural network-based segmentation can help in assessing the substantia nigra in neuromelanin MRI , 2019, Neuroradiology.
[210] L. Esserman,et al. Test–retest repeatability and reproducibility of ADC measures by breast DWI: Results from the ACRIN 6698 trial , 2018, Journal of magnetic resonance imaging : JMRI.
[211] Po-Hsuan Cameron Chen,et al. How to Read Articles That Use Machine Learning: Users' Guides to the Medical Literature. , 2019, JAMA.
[212] Andrew Dienstfrey,et al. Assessing effects of scanner upgrades for clinical studies , 2019, Journal of magnetic resonance imaging : JMRI.
[213] S. Aoki,et al. Brain tissue and myelin volumetric analysis in multiple sclerosis at 3T MRI with various in-plane resolutions using synthetic MRI , 2019, Neuroradiology.
[214] J. Gillard,et al. A Comparison of Black-blood T2 Mapping Sequences for Carotid Vessel Wall Imaging at 3T: An Assessment of Accuracy and Repeatability , 2018, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.
[215] M. Knopp,et al. NCTN Assessment on Current Applications of Radiomics in Oncology. , 2019, International journal of radiation oncology, biology, physics.
[216] Y. Ohno,et al. Radiation dose reduction techniques for chest CT: Principles and clinical results. , 2019, European journal of radiology.
[217] K. Kapur,et al. Reproducibility of Structural and Diffusion Tensor Imaging in the TACERN Multi-Center Study , 2019, Front. Integr. Neurosci..
[218] H. Sugano,et al. Aberrant myelination in patients with Sturge-Weber syndrome analyzed using synthetic quantitative magnetic resonance imaging , 2019, Neuroradiology.
[219] O. Abe,et al. Linearity, Bias, Intrascanner Repeatability, and Interscanner Reproducibility of Quantitative Multidynamic Multiecho Sequence for Rapid Simultaneous Relaxometry at 3 T: A Validation Study With a Standardized Phantom and Healthy Controls , 2019, Investigative radiology.
[220] S. Aoki,et al. 3D quantitative synthetic MRI‐derived cortical thickness and subcortical brain volumes: Scan–rescan repeatability and comparison with conventional T1‐weighted images , 2019, Journal of magnetic resonance imaging : JMRI.
[221] Yogesh Rathi,et al. Retrospective harmonization of multi-site diffusion MRI data acquired with different acquisition parameters , 2019, NeuroImage.
[222] Josef Pfeuffer,et al. Effect of spiral undersampling patterns on FISP MRF parameter maps. , 2019, Magnetic resonance imaging.
[223] A. Lutti,et al. Establishing intra‐ and inter‐vendor reproducibility of T1 relaxation time measurements with 3T MRI , 2018, Magnetic resonance in medicine.
[224] O. Abe,et al. Three-dimensional high-resolution simultaneous quantitative mapping of the whole brain with 3D-QALAS: An accuracy and repeatability study. , 2019, Magnetic resonance imaging.
[225] Petro M. Kostandy,et al. Automated Abdominal Segmentation of CT Scans for Body Composition Analysis Using Deep Learning. , 2019, Radiology.
[226] O. Abe,et al. White Matter Abnormalities in Multiple Sclerosis Evaluated by Quantitative Synthetic MRI, Diffusion Tensor Imaging, and Neurite Orientation Dispersion and Density Imaging , 2019, American Journal of Neuroradiology.
[227] Bram Stieltjes,et al. A Practical Guide to Artificial Intelligence-Based Image Analysis in Radiology. , 2020, Investigative radiology.
[228] O. Abe,et al. Deep Learning Approach for Generating MRA Images From 3D Quantitative Synthetic MRI Without Additional Scans. , 2020, Investigative radiology.
[229] A. Simmons,et al. The reliability of a deep learning model in clinical out-of-distribution MRI data: a multicohort study , 2019, Medical Image Anal..