The Use of Allograft Bone in Lumbar Spine Surgery

Bone grafting is an integral part of many lumbar spinal surgeries. The two choices of bone are autograft and allograft. Each source has its own advantages and disadvantages. The current study is a literature review of allograft bone use in lumbar spine surgery. Allograft bone can be procured in greater quantities than autograft. With standard protocols of harvesting, the risk of disease transfer is negligible. Only fresh-frozen and freeze-dried products are used. Allografts are incorporated slower and to a lesser degree than autografts. Fresh-frozen grafts are stronger, more immunogenic and more completely incorporated than freeze-dried grafts. Allografts used alone or combined with autografts for posterior lumbar spinal procedures have decreased fusion rates compared with autografts. If used anteriorly, allografts are well suited for reconstructive procedures and have good fusion rates, especially if combined with posterior fusions. If used in the proper situations, allograft bone can be used successfully in lumbar spine surgeries.

[1]  H. Burchardt Biology of Cortical Bone Graft Incorporation , 1989 .

[2]  J. Meding,et al.  Critical analysis of strut grafts in anterior spinal fusions. , 1993, Journal of spinal disorders.

[3]  R. Pelker,et al.  Biomechanical properties of bone allografts. , 1983, Clinical orthopaedics and related research.

[4]  J. Wiedel,et al.  Allograft use in orthopedic surgery. , 1994, Orthopedics.

[5]  B. J. Doherty,et al.  Interspace distraction and graft subsidence after anterior lumbar fusion with femoral strut allograft. , 1993, Spine.

[6]  L. Lenke,et al.  Anterior Fresh Frozen Structural Allografts in the Thoracic and Lumbar Spine: Do They Work If Combined With Posterior Fusion and Instrumentation in Adult Patients With Kyphosis or Anterior Column Defects? , 1995, Spine.

[7]  P. Nugent Intertransverse process lumbar fusion with allogeneic fresh frozen bone graft , 1993 .

[8]  J. Evans Biomechanics of lumbar fusion. , 1985, Clinical orthopaedics and related research.

[9]  W. Enneking,et al.  Observations on massive retrieved human allografts. , 1991, The Journal of bone and joint surgery. American volume.

[10]  J. Rodrigo,et al.  Contemporary Bone Graft Physiology and Surgery , 1985, Clinical orthopaedics and related research.

[11]  Stephen M. Klisch,et al.  Biomechanical Analysis of Multilevel Fixation Methods in the Lumbar Spine , 1997, Spine.

[12]  E. Dawson,et al.  Intertransverse process lumbar arthrodesis with allogeneic fresh-frozen bone graft. , 1993, Clinical orthopaedics and related research.

[13]  A. Komender Influence of preservation on some mechanical properties of human haversian bone. , 1976, Materia medica Polona. Polish journal of medicine and pharmacy.

[14]  R. B. Cloward Posterior lumbar interbody fusion updated. , 1985, Clinical orthopaedics and related research.

[15]  K. Heiple,et al.  The effect of histocompatibility matching on canine frozen bone allografts. , 1983, The Journal of bone and joint surgery. American volume.

[16]  Wetzel Ft,et al.  Freeze-dried fibular allograft in anterior spinal surgery: cervical and lumbar applications. , 1993 .

[17]  J. Whelchel Use of Cryopreserved Bone in Spinal Surgery , 1987, Spine.

[18]  W. Hayes,et al.  Compressive Strength of Autologous and Allogenous Bone Grafts for Thoracolumbar and Cervical Spine Fusion , 1990, Spine.

[19]  J. Brantigan Pseudarthrosis Rate After Allograft Posterior Lumbar Interbody Fusion With Pedicle Screw and Plate Fixation , 1994, Spine.

[20]  M. Asselmeier,et al.  A review of allograft processing and sterilization techniques and their role in transmission of the human immunodeficiency virus , 1993, The American journal of sports medicine.

[21]  B. Cunningham,et al.  Compression strength of donor bone for posterior lumbar interbody fusion. , 1993, Spine.

[22]  R E Booth,et al.  Harvesting Autogenous Iliac Bone Grafts: A Review of Complications and Techniques , 1989, Spine.

[23]  R. Watkins,et al.  Comparison of Disc Space Heights after Anterior Lumbar Interbody Fusion , 1989, Spine.

[24]  E. Sedlin,et al.  A rheologic model for cortical bone. A study of the physical properties of human femoral samples. , 1965, Acta orthopaedica Scandinavica. Supplementum.

[25]  T. Lowe,et al.  A Prospective Analysis of Autograft Versus Allograft in Posterolateral Lumbar Fusion in the Same Patient: A Minimum of 1‐Year Follow‐up in 144 Patients , 1994, Spine.

[26]  J. Currey,et al.  The Mechanical Properties of Bone , 1970, Clinical orthopaedics and related research.

[27]  N. Triantafyllou,et al.  The mechanical properties of the lyophylized and irradiated bone grafts. , 1975, Acta orthopaedica Belgica.

[28]  J. Heckman,et al.  Selected Instructional Course Lectures The American Academy of Orthopaedic Surgeons , 2000 .

[29]  H. An,et al.  Prospective comparison of autograft vs. allograft for adult posterolateral lumbar spine fusion: differences among freeze-dried, frozen, and mixed grafts. , 1995, Journal of spinal disorders.

[30]  H. Burchardt Biology of bone transplantation. , 1987, The Orthopedic clinics of North America.

[31]  F. Kummer,et al.  Optimal selection and preparation of fresh frozen corticocancellous allografts for anterior interbody lumbar spinal fusion. , 1997, Journal of spinal disorders.

[32]  M. Newman,et al.  The Failure of Ethylene Oxide Gas-Sterilized Freeze-Dried Bone Graft for Thoracic and Lumbar Spinal Fusion , 1989, Spine.

[33]  V. Goldberg,et al.  Natural history of autografts and allografts. , 1987, Clinical orthopaedics and related research.

[34]  J. Lotz,et al.  Biomechanical Analysis of Lumbosacral Fixation , 1996, Spine.