“No calibration” type sensor in routine amperometric bio-sensing: An example of a disposable hydrogen peroxide biosensor

The predicted potential market size for the use of biosensors in the biomedical sector has correlated closely to the actual global market sales of biosensor devices. Unlike glucose measurement in blood, biosensors for environmental or food analysis are niche markets in which the demand varies and the sale volumes are low. Until now the use of biosensors in these markets has been limited. In contrast, spectrophotometric methods, and particularly enzyme-coupled assays, packaged in simple to use kit form, have proved successful in such fragmented markets and have become, in many cases, the recommended standard method for industrial analysis. The popularity of such kits is the result of disposable consumables, reliable detection methods and most importantly, no requirement for tedious calibration steps (if the Beer-Lambert law is applicable). Disadvantages include sample preparation, multiple and sequential addition of several reagents during the analysis process. We believe that within the environmental and agri-food industries, amperometric biosensor technology could be a valid competitor to the standard spectrophotometric methods; provided that cheap and easy to use methods are proposed. According to industrial users within these fragmented markets, the biggest obstacle for the take up of biosensor technology as a standard method is the requirement for complex pre-calibration. It seems that, to meet the demand of these markets, an essential improvement would be the removal of calibration steps before the use of the biosensor. The electrochemical signal of a large number of amperometric biosensors is dependent upon enzymatic or chemical kinetics that are reliant on operating conditions (enzyme concentrations, temperature, pH) and so necessarily requires a calibration step prior to use. Despite their excellent analytical performances this makes them unattractive for industries that want to use these analytical tools in remote locations using unskilled operators. With spectroscopic methods these calibration steps are unnecessary because, for a given wavelength and a fixed light path, the measured absorbance is directly proportional to the concentration of sample material. This is true for a concentration range for which the Beer-

[1]  A. Danet,et al.  Rapid and sensitive automated method for glucose monitoring in wine processing. , 2004, Journal of agricultural and food chemistry.

[2]  L. Gorton,et al.  The synergetIc effect of redox mediators and peroxidase in a bienzymatic biosensor for glucose assays in FIA , 1999 .

[3]  S. Griveau,et al.  Carbon nanotubes, phthalocyanines and porphyrins: attractive hybrid materials for electrocatalysis and electroanalysis. , 2009, Journal of nanoscience and nanotechnology.

[4]  F Ricci,et al.  Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes. , 2005, Biosensors & bioelectronics.

[5]  N. Murr,et al.  Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode , 1995 .

[6]  A. Karyakin,et al.  Prussian Blue and Its Analogues: Electrochemistry and Analytical Applications , 2001 .

[7]  N. Murr,et al.  Biosensor for determination of glucose and sucrose in fruit juices by flow injection analysis , 2000, Applied biochemistry and biotechnology.

[8]  Jenny Emnéus,et al.  Peroxidase-modified electrodes: Fundamentals and application , 1996 .

[9]  Teodoro Espinosa-Solares,et al.  Macroscopic mass and energy balance of a pilot plant anaerobic bioreactor operated under thermophilic conditions , 2006, Applied biochemistry and biotechnology.

[10]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[11]  S. Piletsky,et al.  Development of Biosensors for the Detection of Hydrogen Peroxide , 2006 .

[12]  Simona Serban,et al.  Redox-flexible NADH oxidase biosensor: A platform for various dehydrogenase bioassays and biosensors , 2006 .

[13]  E. Ferapontova Direct peroxidase bioelectrocatalysis on a variety of electrode materials , 2004 .

[14]  J. Savéant,et al.  Potential-sweep voltammetry: General theory of chemical polarization , 1967 .

[15]  Huangxian Ju,et al.  Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein. , 2007, Biosensors & bioelectronics.