Toward the development of a microcrystal element scanner (MiCES): quickPET II

This work reports on the development and the imaging characteristics of a single ring version of the microcrystal element scanner (MiCES). We refer to this evaluation system as quickPET II The key component of the system is our microcrystal element (MiCE) detectors. Each MiCE detector consists of a 22/spl times/22 array of polished 0.8/spl times/0.8/spl times/10 mm mixed lutetium silicate (MLS) crystals. The crystals are placed within a grid made of a highly reflective polymer film material. The grid optically isolates the crystals and additionally functions as a reflective wrap. The detector unit is directly coupled to a 6+6 cross-anode position sensitive PMT. The PMT signals are fed to a simple resistor network and front-end amplifier card that produces four (X+, X-, Y+, Y-) position and the summed energy signals. QuickPET II is an interim step to the development of the complete MiCES imaging system. It supports whole body static /sup 18/F imaging protocols. QuickPET II consists of 18 MiCE detector modules mounted as a single ring to a vertical gantry. The gantry can rotate /spl plusmn/ 20 degrees. Line source and mouse images have been acquired. Using filtered backprojection (FBP) the resolution for a reconstructed line source has been measured at 1.1 /spl plusmn/0.1 mm FWHM. We have also developed a 2D OSEM reconstruction that includes a model of the system's 2D detector response function. Mouse heart images reconstructed with FBP, OSEM and OSEM with a model for detector blurring (OSEM(DB)) are provided. The final MiCES system will consist of four rings of detectors mounted on a fully rotating gantry; utilize a high bandwidth IEEE 1394a based acquisition system; and support whole body dynamic imaging protocols.

[1]  A. G. Weisenberger,et al.  Optimized readout of small gamma cameras for high resolution single gamma and positron emission imaging , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[2]  M. Montecchi,et al.  Study of some optical glues for the Compact Muon Solenoid at the Large Hadron Collider of CERN , 2001 .

[3]  Thomas K. Lewellen,et al.  Performance characteristics of micro crystal element (MiCE) detectors , 2000 .

[4]  Kisung Lee,et al.  System electronics for the MiCES small animal PET scanner , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[5]  M. Daube-Witherspoon,et al.  Treatment of axial data in three-dimensional PET. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  C. A. Stover,et al.  Giant birefringent optics in multilayer polymer mirrors , 2000, Science.

[7]  P.E. Kinahan,et al.  Pragmatic image reconstruction for the MiCES Fully-3D mouse imaging PET scanner , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[8]  S. Meikle,et al.  The influence of tomograph sensitivity on parameter estimation in small animal imaging studies , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[9]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[10]  T. Lewellen,et al.  Optimization of mounting large crystal arrays to photomultiplier tubes , 2003, IEEE Nuclear Science Symposium Conference Record.

[11]  Robert S. Miyaoka,et al.  A data acquisition system for coincidence imaging using a conventional dual head gamma camera , 1996 .

[12]  Thomas K. Lewellen,et al.  Performance characteristics of a second generation micro crystal element (MiCE2) detector , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[13]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.