Effects of miniscrew orientation on implant stability and resistance to failure.

INTRODUCTION The purpose of this study was to determine the effect of miniscrew implant orientation on the resistance to failure at the implant-bone interface. METHODS Miniscrew implants (IMTEC, Ardmore, Okla) were placed in 9 human cadaver mandibles, oriented at either 90 degrees or 45 degrees to the bone surface, and tested to failure in pull-out (tensile) and shear tests. The line of applied force and the orientation of the implants aligned at 45 degrees were either parallel or perpendicular to the maximum axis of bone stiffness. In the shear tests, the implants aligned at 45 degrees were angled toward and opposing the axis of shear force. RESULTS The implants aligned at 90 degrees had the highest force at failure of all the groups (342 + or - 80.9 N; P <0.001). In the shear tests, the implants that were angled in the same direction as the line of force were the most stable and had the highest force at failure (253 + or - 74.05 N; P <0.001). The implants angled away from the direction of force were the least stable and had the lowest force (87 + or - 27.2 N) at failure. CONCLUSIONS The more closely the long axis of the implant approximates the line of applied force, the greater the stability of the implant and the greater its resistance to failure.

[1]  I Naert,et al.  The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. , 2001, Clinical oral implants research.

[2]  A. Gosain,et al.  Biomechanical Evaluation of Titanium, Biodegradable Plate and Screw, and Cyanoacrylate Glue Fixation Systems in Craniofacial Surgery , 1998, Plastic and reconstructive surgery.

[3]  F. G. Evans,et al.  The mechanical properties of bone. , 1969, Artificial limbs.

[4]  H. Frost,et al.  Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians. , 2009, The Angle orthodontist.

[5]  B Saka,et al.  Mechanical and biomechanical measurements of five currently available osteosynthesis systems of self-tapping screws. , 2000, The British journal of oral & maxillofacial surgery.

[6]  B Melsen,et al.  Miniscrews as orthodontic anchorage: a preliminary report. , 1998, The International journal of adult orthodontics and orthognathic surgery.

[7]  R Kanomi,et al.  Mini-implant for orthodontic anchorage. , 1997, Journal of clinical orthodontics : JCO.

[8]  J Lindström,et al.  Intra-osseous anchorage of dental prostheses. I. Experimental studies. , 1969, Scandinavian journal of plastic and reconstructive surgery.

[9]  P. Branemark,et al.  Intra-Osseous Anchorage of Dental Prostheses , 1970, Scandinavian Journal of Plastic and Reconstructive Surgery.

[10]  D. Laskin,et al.  Analysis of seating and fracturing torque of bicortical screws. , 1994, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[11]  Y Zilberman,et al.  Osseous adaptation to continuous loading of rigid endosseous implants. , 1984, American journal of orthodontics.

[12]  Kenneth A Johnson,et al.  Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. , 2005, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[13]  B Melsen,et al.  Immediate loading of implants used for orthodontic anchorage. , 2000, Clinical orthodontics and research.

[14]  Hiroshi Fukuda,et al.  Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution , 2003, Odontology.

[15]  Robert A. Draughn,et al.  Factors Affecting Mechanical Properties of Bone , 1999 .

[16]  Douglas Jb,et al.  Dental implants used as orthodontic anchorage. , 1987 .

[17]  R. Puers,et al.  Implant design and interface force transfer , 2004 .

[18]  S. Kyung,et al.  Distalization of maxillary molars with a midpalatal miniscrew. , 2003, Journal of clinical orthodontics : JCO.

[19]  Yuehuei H. An,et al.  Mechanical testing of bone and the bone-implant interface , 1999 .

[20]  P. Branemark,et al.  Microcirculatory Studies in Man By High Resolution Vital Microscopy , 1964, Angiology.

[21]  P. Tengvall,et al.  Surface immobilized bisphosphonate improves stainless-steel screw fixation in rats. , 2004, Biomaterials.

[22]  C Bourauel,et al.  Three-dimensional analysis of endosseous palatal implants and bones after vertical, horizontal, and diagonal force application. , 2003, European journal of orthodontics.

[23]  J. Phillips,et al.  The Effects of Varying Pilot Hole Size on the Holding Power of Miniscrews and Microscrews , 1995, Plastic and reconstructive surgery.

[24]  P K Turley,et al.  Orthodontic force application to titanium endosseous implants. , 2009, The Angle orthodontist.

[25]  W. L. Foley,et al.  Torque and pullout analysis of six currently available self-tapping and "emergency" screws. , 1993, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[26]  S. Cowin,et al.  Bone Mechanics Handbook, 2nd Edition. - , 2003 .

[27]  Torsten Jemt,et al.  Osseointegrated titanium implants—a new approach in orthodontic treatment , 1988 .

[28]  H. Frost,et al.  A 2003 update of bone physiology and Wolff's Law for clinicians. , 2009, The Angle orthodontist.

[29]  M. C. M. Wong,et al.  Stability consideration for internal maxillary distractors. , 2003, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[30]  R K Gongloff,et al.  Rigid endosseous implants for orthodontic and orthopedic anchorage. , 1989, The Angle orthodontist.

[31]  E D Schneiderman,et al.  Biomechanical properties of small bone screws. , 1994, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[32]  H. Wehrbein,et al.  Biodegradable implants for orthodontic anchorage. A preliminary biomechanical study , 1996 .

[33]  M. Buckley,et al.  Intrusion anchorage potential of teeth versus rigid endosseous implants: a clinical and radiographic evaluation. , 1995, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[34]  S. Cowin Bone mechanics handbook , 2001 .

[35]  H. Kyung,et al.  Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. , 2001, Journal of clinical orthodontics : JCO.

[36]  K. Higuchi,et al.  The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement. , 1992, The International journal of oral & maxillofacial implants.

[37]  D. Laganá,et al.  Photoelastic analysis of stress distribution on parallel and angled implants after installation of fixed prostheses. , 2004, Brazilian oral research.

[38]  R. Haas,et al.  Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications. , 2001, Clinical oral implants research.

[39]  C. E. Bowman,et al.  Holding power of orthopedic screws in bone. , 1970, Clinical orthopaedics and related research.

[40]  W. L. Foley,et al.  Uniaxial pullout evaluation of internal screw fixation. , 1989, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[41]  N. Sharkey,et al.  Mechanical effects of postmortem changes, preservation, and allograft bone treatments , 2001 .

[42]  P. Dechow,et al.  Variations in cortical material properties throughout the human dentate mandible. , 2003, American journal of physical anthropology.

[43]  W M Smalley,et al.  Osseointegrated titanium implants for maxillofacial protraction in monkeys. , 1988, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[44]  B. C. Pai,et al.  Do miniscrews remain stationary under orthodontic forces? , 2004, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[45]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.