Creation of two tomographic voxel models of paediatric patients in the first year of life.

Tomographic computational models, based on regional segmentation of CT or MRI medical images, have increasingly been proposed as replacements for current stylized mathematical models of human anatomy used in radiation dosimetry studies. While much effort has been devoted towards the creation of adult models, few research studies have been initiated to address the need for models supporting paediatric radiology dosimetry. In this study, two tomographic models were created using a combination of automatic and manual segmentation via a program created in-house using IDL version 5.5. The first model is of a normal 6 day female newborn, and consists of a 512 x 512 x 485 data array. The CT slices of this model were obtained every 1 mm, and 66 different anatomic regions were defined. The second model is of a patient developmentally equivalent to a 2 month male, and was saved as a 512 x 512 x 438 data array. This subject had severe tissue oedema within the gut, kidneys, liver and spleen. The model is thus considered representative of a critically ill child, from a patient subpopulation expected to receive a larger than normal number of diagnostic x-ray exams. The voxel volumes for the two models are 0.35 mm3 and 0.30 mm3, respectively, thus making these models the most detailed in existence for paediatric dosimetry applications. Ratios of organ masses for the UF newborn model to those within the reference ORNL/MIRD model range from highs of 1.2 to 1.7 for the oesophagus and small intestine/colon, respectively, to lows of 0.18 to 0.27 for the mandible and humeri, respectively. For the UF 2 month model, ratios of organ masses in the UF model to those in the 8 week GSF BABY model ranged from highs of 3.7 to 5.2 for the clavicles and spleen, respectively, to lows of 0.2 to 0.3 for the adrenals and scapulae, respectively.

[1]  M. Zankl,et al.  The adult male voxel model ”Golem” segmented from whole-body CT patient data , 2001, Radiation and environmental biophysics.

[2]  W E Bolch,et al.  Surface area overestimation within three-dimensional digital images and its consequence for skeletal dosimetry. , 2002, Medical physics.

[3]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[4]  G Drexler,et al.  The construction of computer tomographic phantoms and their application in radiology and radiation protection , 1988, Radiation and environmental biophysics.

[5]  S. Eiho,et al.  Processing of RI-Angiocardiographic Images , 1976 .

[6]  P B Hoffer,et al.  Computerized three-dimensional segmented human anatomy. , 1994, Medical physics.

[7]  I. Kawrakow Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. , 2000, Medical physics.

[8]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[9]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[10]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[11]  W. Bolch,et al.  Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters. , 2001, Health physics.

[12]  L. Wang,et al.  Development of tissue-simulating optical phantoms: poly-N-isopropylacrylamide solution entrapped inside a hydrogel. , 1999, Physics in medicine and biology.

[13]  D. G. Jones A Realistic Anthrompomorphic Phantom for Calculating Specific Absorbed Fractions of Energy Deposited from Internal Gamma Emitters , 1998 .

[14]  W. Eckelman,et al.  NCRP report no. 93: Ionizing radiation exposure of the population of the United States: National Council on Radiation Protection and Measurements, Bethesda, Maryland (1987). US$15.00 , 1988 .

[15]  W. Bolch,et al.  Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient. , 2002, Medical physics.

[16]  D. Hintenlang,et al.  The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray. , 1998, Health physics.

[17]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[18]  Terry Smith,et al.  Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms , 2000, European Journal of Nuclear Medicine.

[19]  X. Xu,et al.  Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emitters. , 2001, Physics in medicine and biology.

[20]  W. Bolch,et al.  SKELETAL DOSIMETRY VIA NMR MICROSCOPY: INVESTIGATIONS OF SAMPLE REPRODUCIBILITY AND SIGNAL SOURCE , 2002, Health physics.

[21]  W E Bolch,et al.  Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements. , 2002, Physics in medicine and biology.