A numerical study of transcranial focused ultrasound beam propagation at low frequency

The feasibility of transcranial ultrasound focusing with a non-moving phased array and without skull-specific aberration correction was investigated using computer simulations. Three cadaver skull CT image data sets were incorporated into an acoustic wave transmission model to simulate transskull ultrasound wave propagation. Using a 0.25 MHz hemispherical array (125 mm radius of curvature, 250 mm diameter, 24 255 elements), the simulated beams could be focused and steered with transducer element driving phases and amplitude adjusted for focal beam steering in water (water-path). A total of 82 foci, spanning wide ranges of distance in the three orthogonal dimensions, were simulated to test the focal beam steering capability inside the three skulls. The acoustic pressure distribution in a volume of 20 x 20 x 20 mm(3) centred at each focus was calculated with a 0.5 mm spacing in each axis. Clearly defined foci were retained through the skulls (skull-path) in most cases. The skull-path foci were on average 1.6 +/- 0.8 mm shifted from their intended locations. The -3 dB skull-path beam width and length were on average 4.3 +/- 1.0 mm and 7.7 +/- 1.8 mm, respectively. The skull-path sidelobe levels ranged from 25% to 55% of the peak pressure values. The skull-path peak pressure levels were about 10%-40% of their water-path counterparts. Focusing low-frequency beam through skull without skull-specific aberration correction is possible. This method may be useful for applying ultrasound to disrupt the blood-brain barrier for targeted delivery of therapeutic or diagnostic agents, or to induce microbubbles, or for other uses of ultrasound in brain where the required power levels are low and the sharp focusing is not needed.

[1]  Narendra T. Sanghvi,et al.  A Focused Ultrasound System for Tissue Volume Ablation in Deep Seated Brain Sites , 1986, IEEE 1986 Ultrasonics Symposium.

[2]  K Hynynen,et al.  Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo. , 1995, Ultrasound in medicine & biology.

[3]  J.-L. Thomas,et al.  Ultrasonic beam focusing through tissue inhomogeneities with a time reversal mirror: application to transskull therapy , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  K Hynynen,et al.  The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area. , 1999, The Journal of the Acoustical Society of America.

[5]  M. Hennerici,et al.  Transcranial ultrasound-improved thrombolysis: diagnostic vs. therapeutic ultrasound. , 2001, Ultrasound in medicine & biology.

[6]  K. Hynynen,et al.  The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison). , 2003, Ultrasound in medicine & biology.

[7]  J. Barger,et al.  Acoustical properties of the human skull. , 1978, The Journal of the Acoustical Society of America.

[8]  F A Jolesz,et al.  MRI detection of the thermal effects of focused ultrasound on the brain. , 2000, Ultrasound in medicine & biology.

[9]  A. E. Miller,et al.  A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY , 1942, The Journal of general physiology.

[10]  M Tanter,et al.  Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans. , 2003, The Journal of the Acoustical Society of America.

[11]  M. Hennerici,et al.  Low-frequency, low-intensity ultrasound accelerates thrombolysis through the skull. , 1999, Ultrasound in medicine & biology.

[12]  K. Hynynen,et al.  Micro-receiver guided transcranial beam steering , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  K. Hynynen,et al.  Criteria for the design and characterization of large-area arrays for transskull ultrasound surgery and therapy , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[14]  Gregory T. Clement,et al.  A hemisphere array for non-invasive ultrasound brain therapy and surgery. , 2000, Physics in medicine and biology.

[15]  J. T. Kouzmanoff,et al.  Sparse random ultrasound phased array for focal surgery , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  F A Jolesz,et al.  Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. , 1998, Ultrasound in medicine & biology.

[17]  I. Romero,et al.  Transporting therapeutics across the blood-brain barrier. , 1996, Molecular medicine today.

[18]  Gregory T. Clement,et al.  Investigation of a large-area phased array for focused ultrasound surgery through the skull. , 2000, Physics in medicine and biology.

[19]  K. Hynynen,et al.  Focusing of therapeutic ultrasound through a human skull: a numerical study. , 1998, The Journal of the Acoustical Society of America.

[20]  F. Fry,et al.  Further studies of the transkull transmission of an intense focused ultrasonic beam: lesion production at 500 kHz. , 1980, Ultrasound in medicine & biology.

[21]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[22]  F. Fry,et al.  Transkull transmission of an intense focused ultrasonic beam. , 1977, Ultrasound in medicine & biology.

[23]  K Hynynen,et al.  Design and optimization of an aperiodic ultrasound phased array for intracavitary prostate thermal therapies. , 1996, Medical physics.

[24]  G T Clement,et al.  A non-invasive method for focusing ultrasound through the human skull. , 2002, Physics in medicine and biology.

[25]  K. Hynynen,et al.  Trans-skull ultrasound therapy: the feasibility of using image-derived skull thickness information to correct the phase distortion , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Marc Fatar,et al.  Therapeutic ultrasound in ischemic stroke treatment: experimental evidence. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[27]  K. Hynynen,et al.  Apoptosis in ultrasound-produced threshold lesions in the rabbit brain. , 2001, Ultrasound in medicine & biology.

[28]  W J FRY,et al.  Ultrasonic lesions in the mammalian central nervous system. , 1955, Science.

[29]  A. Alexandrov,et al.  Ultrasound‐Enhanced Thrombolysis for Acute Ischemic Stroke: Phase I. Findings of the CLOTBUST Trial , 2004, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[30]  Natalia Vykhodtseva,et al.  500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls , 2004, Magnetic resonance in medicine.

[31]  K. Hynynen,et al.  Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. , 2001, Radiology.

[32]  R. B. Roemer,et al.  Treatment of malignant brain tumors with focused ultrasound hyperthermia and radiation: results of a phase I trial , 1991, Journal of Neuro-Oncology.

[33]  M Pernot,et al.  High power transcranial beam steering for ultrasonic brain therapy. , 2003, Physics in medicine and biology.

[34]  H. Winn,et al.  High-intensity focused ultrasound selectively disrupts the blood-brain barrier in vivo. , 2002, Ultrasound in medicine & biology.