In-vivo polyethylene wear and knee prosthesis longevity estimation

This paper describes an in-vivo polyethylene wear and knee prosthesis longevity estimation approach using an implantable ligament imbalance metric system. Four piezoelectric elements are used to measure the axial force components, on the tibial tray surface and their center of pressure is calculated. This can be used, along with a knee simulator, to estimate polyethylene wear, and the state of the implanted knee prosthesis. Surgeons can exploit this to improve the post operative rehabilitation measures, whereas prosthesis manufacturers can use it to improve prosthesis's strength, geometry and life. The proposed self-powered measurement and telemetry system does not require any external power.

[1]  A J Price,et al.  In vivo measurement of volumetric wear of a total knee replacement. , 2006, The Knee.

[2]  Shantanu Patil,et al.  In vivo knee moments and shear after total knee arthroplasty. , 2007, Journal of biomechanics.

[3]  A Sahlström,et al.  Radiographic wear assessment in a total knee prosthesis. 5- to 9-year follow-up study of 158 knees. , 1996, The Journal of arthroplasty.

[4]  S. E. Irby,et al.  Instrumented implant for measuring tibiofemoral forces. , 1996, Journal of biomechanics.

[5]  Lutz-Peter Nolte,et al.  Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA , 2005, IEEE Transactions on Biomedical Engineering.

[6]  Myron Spector,et al.  Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene , 2003 .

[7]  Eike Jakubowitz,et al.  Effect of joint laxity on polyethylene wear in total knee replacement. , 2010, Journal of biomechanics.

[8]  Michel Jezequel,et al.  Ligament imbalance metrics and an autonomous measurement system for post TKA , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[9]  M. Arzel,et al.  A ligament laxity telemetry system architecture for a knee replacement prosthesis , 2009, 2009 2nd International Symposium on Applied Sciences in Biomedical and Communication Technologies.

[10]  Peter S Walker,et al.  Characterizing the motion of total knee replacements in laboratory tests. , 2003, Clinical orthopaedics and related research.

[11]  J. Liau,et al.  The influence of contact alignment of the tibiofemoral joint of the prostheses in in vitro biomechanical testing. , 1999, Clinical biomechanics.

[12]  Antonius Rohlmann,et al.  Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants , 2007, IEEE Transactions on Biomedical Engineering.

[13]  Yutaka Fukuoka,et al.  Accurate in vivo measurement of polyethylene wear in total knee arthroplasty. , 2002, The Journal of arthroplasty.