Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner.

We acquired five independent topographic images of the optic nerve head of eight normal eyes and eight eyes with primary open-angle glaucoma with a laser tomographic scanner. Each image had a field of view of 15 x 15 degrees with a resolution of 256 x 256 pixels. The pixel size was approximately 15 x 15 microns. The value of a pixel of a topographic image represented the height at this position. The mean height and the standard deviation over the five topographic images were calculated for each of the 65,536 pixel positions. The standard deviation of a single height measurement in normal eyes was 38.7 microns (range, 23.4 to 62.2 microns) for areas in the peripapillary retina and 42.6 microns (range, 24.4 to 53.7 microns) for measurements within the optic nerve head area. In glaucomatous eyes, the standard deviation was 41.2 microns (range, 23.2 to 59.6 microns) in the peripapillary retina and 49.4 microns (range, 28.1 to 72.8 microns) within the optic nerve head. There was no significant difference between the standard deviation of a single height measurement in normal and glaucomatous eyes (P = .34 within the optic nerve head area; P = .57 on peripapillary retina). No correlation was found between standard deviation of the measurements and pupil size or age of the subject.

[1]  C. Margo,et al.  Lens-Induced Granulomatous Uveitis Following Trabeculectomy , 1988 .

[2]  U Klingbeil,et al.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images. , 1986, Archives of ophthalmology.

[3]  W. Green,et al.  Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. , 1982, Archives of ophthalmology.

[4]  P. Lichter Variability of expert observers in evaluating the optic disc. , 1976, Transactions of the American Ophthalmological Society.

[5]  W. L. Ridgway,et al.  The use of diagrams to record changes in glaucomatous disks. , 1975, American journal of ophthalmology.

[6]  P J Airaksinen,et al.  The correlation between optic disk topography measured by the video-ophthalmograph (Rodenstock analyzer) and clinical measurement. , 1985, American journal of ophthalmology.

[7]  H. Schroder,et al.  Confocal Laser Tomographic Scanning Of The Eye , 1989, Optics & Photonics.

[8]  G Zinser,et al.  Reproducibility of topographic measurements of the optic nerve head with laser tomographic scanning. , 1989, Ophthalmology.

[9]  L. Dandona,et al.  Variability of depth measurements of the optic nerve head and peripapillary retina with computerized image analysis. , 1989, Archives of ophthalmology.

[10]  M. B. Shields,et al.  Reproducibility of topographic measurements with the optic nerve head analyzer. , 1987, American journal of ophthalmology.

[11]  G. Dunkelberger,et al.  Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. , 1989, American journal of ophthalmology.

[12]  R. Weinreb,et al.  Active optical depth resolution improvement of the laser tomographic scanner. , 1989, Applied optics.