Usefulness of Computerized Objective Visual Acuity Test System Using Suppression Method

Purpose: The objective visual acuity test is mandatory in certain cases, such as infants, nonverbal subjects, and subjects who need legal assistance. We designed an objective system for visual acuity test (SOVAT) consisting of three components: stimuli applied via a suppression method, display and evaluation and made a suppression method as stimuli component for SOVAT. Usefulness of the SOVAT was evaluated. Methods: The visual stimuli were presented on a high-resolution head-mounted display (HMD). An eye movement tracking program and gaze monitoring device allowed us to monitor the patient's fixation status during the test. The suppression method, in addition to a conventional induction method, was developed to use with the SOVAT and its accuracy and confidence level were evaluated. Results: On the basis of clinical data, we present the reference values for the SOVAT as below. For the induction method, objective visual acuity (smallest pixel size), the presumed subjective visual acuity was 3: 0.35-0.6, 7: 0.05-0.25, 12: below 0.05 and for the suppression method it was 1: 0.6-1.0, 1.5: 0.4-0.7, 3: 0.15-0.4, 5: 0.1-0.2. Conclusions: SOVAT using this suppression method to assess objective visual acuity proved to be more useful than that with a conventional induction method, especially in the range of high visual acuity.

[1]  G. O. Dayton,et al.  DEVELOPMENTAL STUDY OF COORDINATED EYE MOVEMENTS IN THE HUMAN INFANT. I. VISUAL ACUITY IN THE NEWBORN HUMAN: A STUDY BASED ON INDUCED OPTOKINETIC NYSTAGMUS RECORDED BY ELECTRO-OCULOGRAPHY. , 1964, Archives of ophthalmology.

[2]  R. Kanayama,et al.  Computer analysis of optokinetic nystagmus for clinical usefulness. , 1986, Auris, nasus, larynx.

[3]  W Weder,et al.  [Determination of visual acuity using optokinetic nystagmus. A newly developed instrument based on Günther's principle]. , 1987, Klinische Monatsblatter fur Augenheilkunde.

[4]  A A Assaf Optokinetic nystagmus testing using personal computers. , 1991, Optometry and vision science : official publication of the American Academy of Optometry.

[5]  B. H. Schwarting Testing infants' vision; an apparatus for estimating the visual acuity of infants and young children. , 1954, American journal of ophthalmology.

[6]  G V Catford,et al.  Development of visual acuity , 1973, Archives of disease in childhood.

[7]  G. Aylward,et al.  Behavioral and Neurological Characteristics of a Hydranencephalic Infant , 1978, Developmental medicine and child neurology.

[8]  SUBCORTICAL OPTOKINETIC NYSTAGMUS IN THE MONKEY. , 1963 .

[9]  H GOLDMANN [Observations on objective determination of distance vision]. , 1950, Klinische Monatsblatter fur Augenheilkunde und fur augenarztliche Fortbildung.

[10]  T. Iwasaki,et al.  A case of pulmonary amyloidosis associated with multiple myeloma successfully treated with dimethyl sulfoxide. , 1994, Acta haematologica.