A clock state estimator for PTP time synchronization in harsh environmental conditions

In industrial automation networks based on the Precision Time Protocol (PTP) large temperature changes as well as mechanical shocks and vibrations may severely affect the performance of the local oscillators clocking the network nodes, thus making accurate time synchronization challenging. This problem is particularly critical in large industrial networks with long linear paths, as multiple uncertainty sources tend to accumulate while PTP event messages are forwarded towards the slave clocks. In this paper, the performance of a clock state estimator based on a special Kalman filter as well as on a detailed model of the PTP communication mechanism is described. The reported simulation results when the network nodes are subject to changeable environmental conditions provide interesting guidelines to keep synchronization accuracy in industrial networks within given boundaries.

[1]  Daniele Fontanelli,et al.  Accurate time synchronization in PTP-based industrial networks with long linear paths , 2010, 2010 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication.

[2]  H. Abubakari,et al.  IEEE 1588 style synchronization over wireless link , 2008, 2008 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication.

[3]  Claudio Narduzzi,et al.  Performance analysis of Kalman filter-based clock synchronization in IEEE 1588 networks , 2009, 2009 International Symposium on Precision Clock Synchronization for Measurement, Control and Communication.

[4]  Ruxandra Lupas Scheiterer,et al.  An optimal control approach to clock synchronization , 2010, 2010 IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication.

[5]  Josef A. Nossek,et al.  A Kalman Filter Approach To Clock Synchronization Of Cascaded Network Elements , 2009 .

[6]  J. Jasperneite,et al.  Enhancements to the time synchronization standard IEEE-1588 for a system of cascaded bridges , 2004, IEEE International Workshop on Factory Communication Systems, 2004. Proceedings..

[7]  P. Tavella,et al.  The clock model and its relationship with the Allan and related variances , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Thia Kirubarajan,et al.  Estimation with Applications to Tracking and Navigation: Theory, Algorithms and Software , 2001 .

[9]  Aggelos Bletsas Evaluation of Kalman filtering for network time keeping , 2005 .