A mechatronic valve in the management of hydrocephalus: methods and performance

The problem of excess cerebrospinal fluid in the brain (hydrocephalus) is generally managed using a passive pressure or flow regulated mechanical shunt. Despite the success of such devices, they have been plagued with a number of problems. It is desirable to have a shunt valve that responds dynamically to the changing needs of the patient, opening and closing according to a dynamic physiological pattern, rather than simply to the hydrostatic pressure across the valve. Such a valve would by necessity be mechatronic, electronically controlled by software. In this article, different methods for controlling such a mechatronic valve are explored, and the effect of current hydrocephalus management techniques on the intracranial hydrodynamics of acute hydrocephalus patient compared with those based on a mechatronic valve was investigated using numerical simulation. Furthermore, the performance of these techniques was evaluated based on a proposed multi-dimensional figure of merit. In addition, an empirical valve schedule was proposed based on different criterions. An intelligent shunting system is seen as the future in hydrocephalus management and treatment, and towards this end, suitably programmed mechatronic valves would attempt to mimic normal physiology and potentially overcome many of the problems associated with current mechanical valves.

[1]  Hyeun Joong Yoon,et al.  Micro devices for a cerebrospinal fluid (CSF) shunt system , 2004 .

[2]  Ian R. Manchester,et al.  Real-time estimation of cerebrospinal fluid system parameters via oscillating pressure infusion , 2010, Medical & Biological Engineering & Computing.

[3]  Hervé Delingette,et al.  Dynamic Model of Communicating Hydrocephalus for Surgery Simulation , 2007, IEEE Transactions on Biomedical Engineering.

[4]  Xiao Hu,et al.  Regression analysis for peak designation in pulsatile pressure signals , 2009, Medical & Biological Engineering & Computing.

[5]  S. Leonhardt,et al.  A Model for Intracranial Hydrodynamics , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[6]  Roberto Hornero,et al.  Analysis of intracranial pressure during acute intracranial hypertension using Lempel–Ziv complexity: further evidence , 2007, Medical & Biological Engineering & Computing.

[7]  N. Alperin,et al.  MR-Intracranial pressure (ICP): a method to measure intracranial elastance and pressure noninvasively by means of MR imaging: baboon and human study. , 2000, Radiology.

[8]  Westgate Road,et al.  Assessment of cerebrospinal fluid outflow resistance , 2007 .

[9]  Alec Ginggen Optimization of the treatment of hydrocephalus by the non-invasive measurement of the intra-cranial pressure , 2007 .

[10]  Iain Chambers,et al.  Assessment of cerebrospinal fluid outflow resistance , 2007, Medical & Biological Engineering & Computing.

[11]  Jan Malm,et al.  Adaptive method for assessment of cerebrospinal fluid outflow conductance , 2007, Medical & Biological Engineering & Computing.

[12]  Waleed Al-Nuaimy,et al.  Design of an intelligent and personalised shunting system for hydrocephalus , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  M. Ursino A mathematical study of human intracranial hydrodynamics part 1—The cerebrospinal fluid pulse pressure , 2006, Annals of Biomedical Engineering.