Advanced Observations of Lightning Induced Voltage on Power Distribution Lines (II)

The authors discuss observations of induced voltages on the experimental overhead distribution line at a power plant facing the Japan Sea from October 1984 through March 1988. Waveforms of induced voltage from lightning strokes to a high stack of the power plant were measured simultaneously with the current waveforms of the lightning stroke to the stack. The polarity of lightning-induced voltage is opposite to that of lightning stroke current, regardless of the season. Except for unusual conditions, lightning induced voltages have a unipolar waveform. The lightning-induced voltage on the closest point of a distribution line to the lightning striking point is the maximum. The induced voltage waveforms generated on a distribution line were calculated by means of improved numerical analysis which took the height of the stack into consideration. The calculated results agree better with the measured waveforms than made those made by means of an earlier analysis method. It is clarified that bipolar induced voltages are not produced by usual lightning stroke currents. >

[1]  A. C. Liew,et al.  Extension of the Chowdhuri-Gross Model for Lightning Induced Voltage on Overhead Lines , 1986, IEEE Power Engineering Review.

[2]  S. Yokoyama Calculation of Lightning-Induced Voltages on Overhead Multiconductor Systems , 1984, IEEE Power Engineering Review.

[3]  Kunihiko Miyake,et al.  Simultaneous Measurement of Lightning Induced Voltages with Associated Stroke Currents , 1983, IEEE Transactions on Power Apparatus and Systems.

[4]  A. J. Eriksson,et al.  Lightning performance and overvoltage surge studies on a rural distribution line , 1982 .

[5]  A. Eriksson,et al.  Lightning-Induced Overvoltages on Overhead Distribution Lines , 1982 .

[6]  V. P. Idone,et al.  Lightning return stroke velocities in the thunderstorm research international program (TRIP) , 1982 .

[7]  M. Uman,et al.  Lightning Induced Voltages on Power Lines: Theory , 1984, IEEE Power Engineering Review.

[8]  M. Nagano,et al.  Measurements of Steep-Front Lightning Surge Voltages on Distribution Lines , 1983, IEEE Transactions on Power Apparatus and Systems.

[9]  S. Yokoyama Experimental analysis of earth wires for induced lightning surges , 1980 .

[10]  Pritindra Chowdhuri,et al.  Voltage surges induced on overhead lines by lightning strokes , 1967 .

[11]  Mat Darveniza,et al.  Lightning Induced Voltages on Power Lines: Experiment , 1984, IEEE Transactions on Power Apparatus and Systems.

[12]  R. P. Fieux,et al.  Research on Artificiallyu Triggered Lightning in France , 1978, IEEE Transactions on Power Apparatus and Systems.

[13]  Hiroaki Koga,et al.  Lightning Surge Waves Induced on Overhead Lines , 1979 .