Phase versus amplitude sorting of 4D‐CT data

Image quality of CT scans suffers when objects undergo motion. Respiratory motion causes artifacts, which prevents adequate visualization of anatomy. Four‐dimensional CT (4D‐CT) is a method in which image reconstruction of moving objects is retrospectively gated according to the recorded phase information of the monitored motion pattern. Although several groups have investigated the use of 4D‐CT in radiotherapy, little has been detailed with regard to the sorting method. We present a new retrospective gating technique with sorting based on the amplitude of the motion trace. This method is compared to previously developed methods that sort based on phase. A 16‐slice CT scanner (Sensation 16, Siemens Medical Solutions, Erlangen, Germany) was used to acquire images of two phantoms on a motion platform moving in two dimensions. The motion was monitored using a strain gauge inserted inside an adjustable belt. A 180° interpolation was used for reconstruction after gating. Significant improvement using the amplitude‐sorting technique was observed, particularly when testing nonperiodic motion functions. PACS numbers: 87.59.Fm, 87.53.Kn, 87.57.Ce

[1]  J. Itami,et al.  Target volume definition for upper abdominal irradiation using CT scans obtained during inhale and exhale phases. , 2000, International journal of radiation oncology, biology, physics.

[2]  Cynthia H McCollough,et al.  The phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid. , 2004, Medical physics.

[3]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[4]  G Starkschall,et al.  Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. , 2001, International journal of radiation oncology, biology, physics.

[5]  James M Balter,et al.  Evaluation of the influence of breathing on the movement and modeling of lung tumors. , 2002, International journal of radiation oncology, biology, physics.

[6]  J C Rosenwald,et al.  Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing. , 2001, International journal of radiation oncology, biology, physics.

[7]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[8]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[9]  T. Landberg,et al.  What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[11]  J Simon,et al.  Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system. , 2003, Medical physics.

[12]  Mark Ruschin,et al.  Digital fluoroscopy to quantify lung tumor motion: potential for patient-specific planning target volumes. , 2003, International journal of radiation oncology, biology, physics.

[13]  Jürgen Debus,et al.  The Use of the Multislice CT for the Determination of Respiratory Lung Tumor Movement in Stereotactic Single-Dose Irradiation , 2003, Strahlentherapie und Onkologie.

[14]  Isabelle M Gagné,et al.  The impact of tumor motion upon CT image integrity and target delineation. , 2004, Medical physics.

[15]  Nzhde Agazaryan,et al.  An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT. , 2002, Medical physics.

[16]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[17]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[18]  Tinsu Pan,et al.  Four-dimensional computed tomography: image formation and clinical protocol. , 2005, Medical physics.

[19]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[20]  George Starkschall,et al.  Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion. , 2004, International journal of radiation oncology, biology, physics.

[21]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.