The impact of bone size on broadband ultrasound attenuation.

Quantitative ultrasound (QUS) is a simple, inexpensive and radiation-free technique to study skeletal status in osteoporosis. Broadband ultrasound attenuation (BUA) is typically used without normalizing for bone thickness. We investigated the impact of bone thickness on BUA, both in in vitro and in vivo, using commercially available ultrasound scanners (Walker Sonix UBA 575 and 575+). For the study in vitro, we analyzed 12 paired cubes (12 x 12 x 12 mm3) of bovine trabecular bone cut from six "parent" blocks (24 x 12 x 12 mm3). These "parent" blocks showed a fairly homogeneous structure as assessed by conventional radiography. BUA and dual x-ray absorptiometry (DXA) measurements of bone mineral density (BMD) were obtained. The difference between the paired cubes was significant for BUA (p < 0.001), but not for BMD (p > 0.05). The BUA of the "parent" blocks was larger by 32-92% than the average BUA of the corresponding paired cubes, and always less than the sum of the paired cubes (5-34%). BUA thus added up in a complex and nonlinear fashion. Measurements in vivo of the calcaneal bone width demonstrated on radiographs (study in vivo I, 28 postmenopausal women) and CT images (study in vivo II, 17 women) showed a small, positive but not significant correlation with BUA (r2 = 0.13 and r2 = 0.007, p > 0.05). The magnitude of this effect provides further evidence that BUA does not scale linearly with bone size. Our results indicate that simple normalization of BUA data by specifying the results in decibels per megahertz per millimeter units may not be appropriate.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  M. Cawley,et al.  Broadband ultrasonic attenuation in the os calcis and single photon absorptiometry in the distal forearm: a comparative study. , 1986, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[2]  C. Langton,et al.  The measurement of broadband ultrasonic attenuation in cancellous bone. , 1984, Engineering in medicine.

[3]  K Engelke,et al.  Site‐matched calcaneal measurements of broad‐band ultrasound attenuation and single X‐ray absorptiometry: Do they measure different skeletal properties? , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[4]  R H Gold,et al.  Osteoporosis and bone density measurement methods. , 1991, Clinical orthopaedics and related research.

[5]  J A Kanis,et al.  Assessment of broadband ultrasound attenuation in the os calcis in vitro. , 1990, Clinical science.

[6]  J. Kanis,et al.  Broadband ultrasound attenuation in the os calcis: relationship to bone mineral at other skeletal sites. , 1990, Clinical science.

[7]  T. J. Kennett,et al.  Bone density measured by photon scattering. II. Inherent sources of error. , 1976, Physics in medicine and biology.

[8]  Thomas A. Einhorn,et al.  Perspectives: Ultrasound assessment of bone , 1993 .

[9]  D. Comar,et al.  In vivo analysis of bone calcium by local neutron activation of the hand: results in normal and osteoporotic subjects. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  C M Langton,et al.  Comparison of broadband ultrasonic attenuation of the os calcis and quantitative computed tomography of the distal radius. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.