Ultrasound-mediated destruction of contrast agents. Effect of ultrasound intensity, exposure, and frequency.

RATIONALE AND OBJECTIVES Although ultrasound contrast microbubbles theoretically could serve as tracers for the noninvasive quantification of blood flow, results have been inconsistent. Accurate quantification may be limited by ultrasound energy-mediated microbubble destruction. This study examined the effect of different ultrasound delivery parameters on microbubble destruction. METHODS Experiments were performed in an in vitro hydraulic perfusion model consisting of a thin-walled rubber tube encased in agar. Ultrasonic parameters tested during different parts of the experiment were (1) intensity, (2) duration, and (3) frequency. Four ultrasound contrast agents: Aerosomes MRX115 (ImaRx Pharmaceuticals Corp., Tucson, AZ), Imagent AF0150 US (Alliance Pharmaceutical Corp., San Diego, CA), Levovist (Berlex Laboratories, Wayne, NJ), and Echogen (Sonus Pharmaceuticals, Bothel, WA) were imaged with three different ultrasound systems: ATL Ultramark AM-9 HDI, Vingmed 800 and Hewlett-Packard 2500. RESULTS Microbubble destruction and reductions in reflectivity were noted in all agents tested. Although no significant reductions in counts or reflectivity occurred at 0.3 W/cm2 with any agent, exposure to 25 W/cm2 produced more than 80% reductions in both microbubble counts (P < 0.0001) and reflectivity (P < 0.0001). Declines in reflectivity were increased by longer exposure to ultrasound (P < 0.0001); slower flow through an ultrasound beam (P < 0.0001); continuous, rather than intermittent, imaging (P = 0.0002); use of a higher pulse repetition rate (P < 0.0001); and exposure to 2.5 MHz, rather than 7.5 MHz, ultrasound (P < 0.0001). CONCLUSIONS Ultrasound energy-mediated destruction of contrast microbubbles is a function of many factors, including ultrasound intensity, duration, and frequency. Optimization of ultrasound delivery parameters may be used to maximize or minimize the destruction of ultrasound contrast agents.

[1]  T. Porter,et al.  Increased ultrasound contrast and decreased microbubble destruction rates with triggered ultrasound imaging. , 1996, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  J. Seward,et al.  Second harmonic imaging of an intravenously administered echocardiographic contrast agent: Visualization of coronary arteries and measurement of coronary blood flow. , 1996, Journal of the American College of Cardiology.

[3]  A. Weyman,et al.  Pulsatile pressure affects the disappearance of echocardiographic contrast agents. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  S. Kaul,et al.  Technical factors that influence the determination of microbubble transit rate during contrast echocardiography. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[5]  S. Gottlieb,et al.  Effect of pressure on echocardiographic videodensity from sonicated albumin: an in vitro model. , 1995, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[6]  S. Kaul,et al.  Attenuation deforms time-intensity curves during contrast echocardiography: implications for assessment of mean transit rates. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  B. Vandenberg,et al.  Acoustic lability of albumin microspheres. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  A. Weyman,et al.  Effect of static pressure on the disappearance rate of specific echocardiographic contrast agents. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[9]  M. Trivella,et al.  Intracoronary air-filled albumin microspheres for myocardial blood flow measurement. , 1993, Journal of the American College of Cardiology.

[10]  S Akselrod,et al.  Myocardial regional blood flow: quantitative measurement by computer analysis of contrast enhanced echocardiographic images. , 1993, Ultrasound in medicine & biology.