Resolution enhancement in single‐shot imaging using simultaneous acquisition of spatial harmonics (SMASH)

Spatial resolution in single‐shot imaging is limited by signal attenuation due to relaxation of transverse magnetization. This effect can be reduced by minimizing acquisition times through the use of short interecho spacings. However, the minimum interecho spacing is constrained by limits on gradient switching rates, radiofrequency (RF) power deposition and RF pulse length. Recently, simultaneous acquisition of spatial harmonics (SMASH) has been introduced as a method to acquire magnetic resonance images at increased speeds using a reduced number of phase‐encoding gradient steps by extracting spatial information contained in an RF coil array. In this study, it is shown that SMASH can be used to reduce the effects of relaxation, resulting in single‐shot images with increased spatial resolution without increasing imaging time. After a brief theoretical discussion, two strategies to reduce signal attenuation and increase spatial resolution in single‐shot imaging are introduced and their performance is evaluated in phantom studies. In vivo single‐shot echoplanar imaging (EPI), BURST, and half‐Fourier single‐shot turbo spin‐echo (HASTE) images are then presented demonstrating the practical implementation of these resolution enhancement strategies. Images acquired with SMASH show increased spatial resolution and improved image quality when compared with images obtained with the conventional acquisitions. The general principles presented for imaging with SMASH can also be applied to other partially parallel imaging techniques. Magn Reson Med 41:1236–1245, 1999. © 1999 Wiley‐Liss, Inc.

[1]  R. Edelman,et al.  Signal‐to‐noise ratio and signal‐to‐noise efficiency in SMASH imaging , 1999, Magnetic resonance in medicine.

[2]  K. Lovblad,et al.  Half‐fourier BURST imaging on a clinical scanner , 1997, Magnetic resonance in medicine.

[3]  J B Ra,et al.  Fast imaging using subencoding data sets from multiple detectors , 1993, Magnetic resonance in medicine.

[4]  J W Carlson,et al.  Imaging time reduction through multiple receiver coil data acquisition and image reconstruction , 1993, Magnetic resonance in medicine.

[5]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[6]  J C Gore,et al.  The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI , 1992, Magnetic resonance in medicine.

[7]  D. Feinberg,et al.  Single‐Shot GRASE Imaging without Fast Gradients , 1992, Magnetic resonance in medicine.

[8]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[9]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[10]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[11]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .