Design and Implementation of a Speed-Loop-Periodic-Controller-Based Fault-Tolerant SPMSM Drive System

This paper proposes a speed-loop periodic controller design for fault-tolerant surface permanent magnet synchronous motor (SPMSM) drive systems. Faulty conditions, including an open insulated-gate bipolar transistor (IGBT), a short-circuited IGBT, or a Hall-effect current sensor fault are investigated. The fault-tolerant SPMSM drive system using a speed-loop periodic controller has better performance than when using a speed-loop PI controller under normal or faulty conditions. The superiority of the proposed speed-loop-periodic-controller-based SPMSM drive system includes faster transient responses and better load disturbance responses. A detailed design of the speed-loop periodic controller and its related fault-tolerant method, including fault detection, diagnosis, isolation, and control are included. In addition, a current estimator is also proposed to estimate the stator current. When the Hall-effect current sensor is faulty, the estimated current is used to replace the current of the faulty sensor. A 32-bit digital signal processor, type TMS-320F-2808, is used to execute the fault-tolerant method and speed-loop periodic control. Measured experimental results validate the theoretical analysis. The proposed implementation of a fault-tolerant SPMSM drive system and speed-loop periodic controller design can be easily applied in industry due to its simplicity.

[1]  Yang Zheng,et al.  Fault-Tolerant Control of Paralleled-Voltage-Source-Inverter-Fed PMSM Drives , 2015, IEEE Transactions on Industrial Electronics.

[2]  M. Naidu,et al.  Fault-Tolerant Permanent Magnet Motor Drive Topologies for Automotive X-By-Wire Systems , 2010 .

[3]  Scott D. Sudhoff,et al.  Analysis of Electric Machinery and Drive Systems , 1995 .

[4]  Mitja Nemec,et al.  Single Open-phase Fault Detection with Fault-Tolerant Control of an Inverter-fed Permanent Magnet Synchronous Machine , 2014 .

[5]  Tian-Hua Liu,et al.  Fault-tolerant control for a dual-PMSM drive system , 2016 .

[6]  Primoz Bajec,et al.  Cost-Effective Three-Phase PMSM Drive Tolerant to Open-Phase Fault , 2015, IEEE Transactions on Industrial Electronics.

[7]  Mitja Nemec,et al.  Detekcija odspojene faze i na kvarove otporno upravljanje pretvaračem napajanim sinkronim motorom s permanentnim magnetima , 2015 .

[8]  Adel Nasiri Full Digital Current Control of Permanent Magnet Synchronous Motors for Vehicular Applications , 2007, IEEE Transactions on Vehicular Technology.

[9]  D. Mahinda Vilathgamuwa,et al.  Sensor Fault-Resilient Control of Interior Permanent-Magnet Synchronous Motor Drives , 2015, IEEE/ASME Transactions on Mechatronics.

[10]  He Zhang,et al.  PWM-VSI Fault Diagnosis for a PMSM Drive Based on the Fuzzy Logic Approach , 2019, IEEE Transactions on Power Electronics.

[11]  Seung-Ki Sul,et al.  Control of Electric Machine Drive Systems , 2011 .

[12]  Myung-Joong Youn,et al.  An MRAS-Based Diagnosis of Open-Circuit Fault in PWM Voltage-Source Inverters for PM Synchronous Motor Drive Systems , 2013, IEEE Transactions on Power Electronics.

[13]  Bruce A. Francis,et al.  The internal model principle of control theory , 1976, Autom..

[14]  Silverio Bolognani,et al.  Experimental fault-tolerant control of a PMSM drive , 2000, IEEE Trans. Ind. Electron..

[15]  Li Sun,et al.  Current Residual Vector-Based Open-Switch Fault Diagnosis of Inverters in PMSM Drive Systems , 2015, IEEE Transactions on Power Electronics.

[16]  Fabien Meinguet,et al.  A Method for Fault Detection and Isolation Based on the Processing of Multiple Diagnostic Indices: Application to Inverter Faults in AC Drives , 2013, IEEE Transactions on Vehicular Technology.

[17]  Ming Cheng,et al.  Detection and Discrimination of Open-Phase Fault in Permanent Magnet Synchronous Motor Drive System , 2016, IEEE Transactions on Power Electronics.

[18]  Imed Jlassi,et al.  A Robust Observer-Based Method for IGBTs and Current Sensors Fault Diagnosis in Voltage-Source Inverters of PMSM Drives , 2017, IEEE Transactions on Industry Applications.

[19]  Ming Cheng,et al.  Fault-Tolerant Control of Dual Three-Phase Permanent-Magnet Synchronous Machine Drives Under Open-Phase Faults , 2017, IEEE Transactions on Power Electronics.

[20]  Hongfen Bai,et al.  Fault-tolerant control for a dual-winding fault-tolerant permanent magnet motor drive based on SVPWM , 2017 .

[21]  Barrie Mecrow,et al.  A fault tolerant electric drive for an aircraft nose wheel steering actuator , 2010 .

[22]  Hai Yu,et al.  Active Fault-Tolerant Control for Electric Vehicles With Independently Driven Rear In-Wheel Motors Against Certain Actuator Faults , 2016, IEEE Transactions on Control Systems Technology.

[23]  S.E. Schulz,et al.  Fault detection and fault-tolerant control of interior permanent-magnet motor drive system for electric vehicle , 2003, IEEE Transactions on Industry Applications.

[24]  Frede Blaabjerg,et al.  Periodic Control of Power Electronic Converters , 2016 .

[25]  Rolf Isermann,et al.  Fault-Diagnosis Applications: Model-Based Condition Monitoring: Actuators, Drives, Machinery, Plants, Sensors, and Fault-tolerant Systems , 2011 .

[26]  Hanlin Liu,et al.  A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems , 2017, IEEE Transactions on Power Electronics.

[27]  Rongrong Wang,et al.  Fault-tolerant control with active fault diagnosis for four-wheel independently-driven electric ground vehicles , 2011, Proceedings of the 2011 American Control Conference.