Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Background Our understanding of fretting and corrosion at head-neck junctions in modular THAs in vivo is based largely on the analysis of retrieved implants removed for various diagnoses. Little is known about the condition of head-neck tapers in well-functioning THAs. Questions/purposes Regarding a cohort of well-functioning autopsy-retrieved modular THAs, we asked: (1) Does trunnion geometry or femoral head material affect the pull-off force of the femoral head? (2) Is there a relationship between trunnion damage and length of implantation time, head diameter, and neck length? (3) Does visual damage scoring accurately determine the presence or absence of corrosion on cobalt-chrome trunnions? Methods Sixty-six femoral stems and engaged femoral heads were retrieved at autopsy from 53 patients at Anderson Orthopaedic Research Institute from 1998 to 2014. Ten stems were excluded for low stem design group size or insufficient head-stem clearance for pull-off testing, leaving a cohort of 56 THAs with a median implantation time of 10 years (range, 1-24 years). The femoral stems included three cobalt-chrome (CoCr) designs from a single manufacturer with either a 12/14 or 14/16 trunnion design (N = 36 and 20, respectively) mated with alumina or CoCr heads (N = 13 and 43, respectively). The force required to pull off the femoral heads was measured using a uniaxial load frame according to ASTM F2009-00. Mating surfaces were visually examined to assess the presence and severity of fretting and corrosion using a modified Goldberg scoring system. Three 12/14 trunnions of similar implantation lengths and varied damage scores were selected for imaging with a scanning electron microscope (SEM) and energy dispersive x-ray analysis (EDAX) to confirm the absence or presence of corrosion damage. Results No difference was seen in pull-off force between groups based on trunnion geometry and head material (median [range], alumina-12/14: 3127 [2320-6992] N, alumina-14/16: 2670 [1095-7919] N, CoCr-12/14: 2255 [1332-5939] N, CoCr-14/16: 2812 [1655-4246] N; p = 0.132). A positive correlation was found between damage score and length of implantation (&rgr; = 0.543, p < 0.001). However, no correlation between damage score and either head diameter or neck length was found (&rgr; = -0.012, p = 0.930 and &rgr; < 0.001, p = 0.995, respectively). In all, 39 of 56 specimens demonstrated no fretting or corrosion, and 16 specimens had mild damage scores. One specimen demonstrated severe corrosion without visual evidence of fretting. The presence of intergranular corrosion on this trunnion was determined by SEM imaging and EDAX. The absence of corrosion products on two trunnions with no observed damage was confirmed. Conclusions This study found little evidence of fretting and corrosion in a cohort of well-functioning CoCr-CoCr and alumina-CoCr head-neck couples. Further studies are necessary to characterize fretting and corrosion at head-neck junctions of well-functioning implants of other designs and manufacturers. Clinical Relevance The results from this study suggest that patients with well-functioning THAs using polyethylene bearing surfaces with alumina or CoCr heads appear to be at low risk for trunnion corrosion for the specific CoCr alloy stems and trunnion geometries analyzed here.

[1]  S. Kurtz,et al.  Technical Note: Is Corrosion a Threat to the Strength of the Taper Connection in Femoral Components of Total Hip Replacements? , 2017 .

[2]  A. DiGioia,et al.  Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head. , 2017, The Journal of arthroplasty.

[3]  B. McGrory,et al.  Ten-Year Cross-Sectional Study of Mechanically Assisted Crevice Corrosion in 1352 Consecutive Patients With Metal-on-Polyethylene Total Hip Arthroplasty. , 2017, The Journal of arthroplasty.

[4]  M. Teeter,et al.  Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty? , 2016, The Journal of arthroplasty.

[5]  S. Kurtz,et al.  Does Taper Size Have an Effect on Taper Damage in Retrieved Metal-on-Polyethylene Total Hip Devices? , 2016, The Journal of arthroplasty.

[6]  T. Wright,et al.  Flexural Rigidity, Taper Angle, and Contact Length Affect Fretting of the Femoral Stem Trunnion in Total Hip Arthroplasty. , 2016, The Journal of arthroplasty.

[7]  M. Teeter,et al.  Tribocorrosion: Ceramic and Oxidized Zirconium vs Cobalt-Chromium Heads in Total Hip Arthroplasty. , 2016, The Journal of arthroplasty.

[8]  J. Jacobs Corrosion at the Head-Neck Junction: Why Is This Happening Now? , 2016, The Journal of arthroplasty.

[9]  G. Schmidig,et al.  Evaluation of surgical impaction technique and how it affects locking strength of the head–stem taper junction , 2016, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  Michael A. Mont,et al.  Trunnionosis in total hip arthroplasty: a review , 2016, Journal of Orthopaedics and Traumatology.

[11]  T. Wright,et al.  Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties , 2016, Clinical orthopaedics and related research.

[12]  B. McGrory,et al.  A High Prevalence of Corrosion at the Head-Neck Taper with Contemporary Zimmer Non-Cemented Femoral Hip Components. , 2015, The Journal of arthroplasty.

[13]  M. Teeter,et al.  Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty. , 2015, The Journal of arthroplasty.

[14]  D. Howie,et al.  Head-Neck Taper Corrosion in Hip Arthroplasty , 2015, BioMed research international.

[15]  S. Kurtz,et al.  Gross trunnion failure after primary total hip arthroplasty. , 2015, The Journal of arthroplasty.

[16]  T. Wright,et al.  What is the Trouble With Trunnions? , 2014, Clinical orthopaedics and related research.

[17]  M. Wimmer,et al.  Intergranular pitting corrosion of CoCrMo biomedical implant alloy. , 2014, Journal of biomedical materials research. Part B, Applied biomaterials.

[18]  S. Kurtz,et al.  Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study. , 2013, The Journal of arthroplasty.

[19]  S. Kurtz,et al.  Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study , 2013, Clinical orthopaedics and related research.

[20]  U. Wyss,et al.  The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints. , 2013, The Journal of arthroplasty.

[21]  R. Berger,et al.  Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. , 2012, The Journal of bone and joint surgery. American volume.

[22]  R. Barrack,et al.  The effects of blood and fat on Morse taper disassembly forces. , 2009, American journal of orthopedics.

[23]  C. Lohmann,et al.  Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. , 2005, The Journal of bone and joint surgery. American volume.

[24]  J. Jacobs,et al.  Differences in the fretting corrosion of metal–metal and ceramic–metal modular junctions of total hip replacements , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[25]  Sue Leurgans,et al.  A Multicenter Retrieval Study of the Taper Interfaces of Modular Hip Prostheses , 2002, Clinical orthopaedics and related research.

[26]  Joshua J. Jacobs,et al.  Corrosion of metal orthopaedic implants. , 1998, The Journal of bone and joint surgery. American volume.

[27]  J. Galante,et al.  Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. , 1994, The Journal of bone and joint surgery. American volume.

[28]  J. Jacobs,et al.  Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. , 1994, The Journal of bone and joint surgery. American volume.

[29]  J L Gilbert,et al.  In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. , 1993, Journal of biomedical materials research.