Reconstruction Technique of Distorted Sensor Signals With Low-Pass NGD Function

This paper develops a new reconstruction technique of undesirable signal distortion generated by sensor electronic circuits. The introduced reconstruction technique is originally realized with unfamiliar low-pass negative group delay (NGD) function. The feasibility condition of the proposed reconstruction technique in function of the sensor signal spectrum bandwidth under consideration is elaborated. The reconstruction technique principle is theoretically introduced by means of identification of low-pass NGD function parameters and the appropriated circuit topology. The unfamiliar low-pass NGD function analysis and synthesis equations are established. As an example, for the feasibility study, an RC-network based low-pass active cell is considered to implement the low-pass NGD function. A design method of NGD circuit in function of the sensor distortion transfer function is described in different successive steps. The developed NGD reconstruction technique is validated by different proofs of concept. First, transient simulations are carried out with Gaussian and sinc analytical signals. Then, experimental feasibility study is also performed with arbitrary waveform signal. As expected, the NGD reconstruction technique efficiency is confirmed with improvement of distorted signal integrity parameters and cross correlation better than 97%.

[1]  Zhu Han,et al.  Distortion minimization via adaptive digital and analog transmission for energy harvesting-based wireless sensor networks , 2015, 2015 IEEE Global Conference on Signal and Information Processing (GlobalSIP).

[2]  Bharat Gupta,et al.  A Literature Review on Current and Proposed Technologies of Noninvasive Blood Pressure Measurement. , 2017, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[3]  Ye Li,et al.  A Low-Power Dynamic-Range Relaxed Analog Front End for Wearable Heart Rate and Blood Oximetry Sensor , 2019, IEEE Sensors Journal.

[4]  R. Ishikawa,et al.  Group Delay Equalized UWB InGaP/GaAs HBT MMIC Amplifier Using Negative Group Delay Circuits , 2009, IEEE Transactions on Microwave Theory and Techniques.

[5]  Marian Codreanu,et al.  Distributed Distortion-Rate Optimized Compressed Sensing in Wireless Sensor Networks , 2018, IEEE Transactions on Communications.

[6]  H. Barthelemy,et al.  An inertial smart-sensor based on silicon nanowires for wireless sportive activity monitoring , 2011, 2011 IEEE SENSORS Proceedings.

[7]  Guoai Xu,et al.  A Robust Mutual Authentication Scheme Based on Elliptic Curve Cryptography for Telecare Medical Information Systems , 2018, IEEE Access.

[8]  Greg E. Bridges,et al.  Asymptotic Limits of Negative Group Delay in Active Resonator-Based Distributed Circuits , 2011, IEEE Transactions on Circuits and Systems I: Regular Papers.

[9]  Suhada Jayasuriya,et al.  Filtering of Signals Distorted by Sensor Nonlinearity , 2002 .

[10]  G. Jourdan,et al.  M&NEMS: A new approach for ultra-low cost 3D inertial sensor , 2009, 2009 IEEE Sensors.

[11]  M. Kitano,et al.  Negative group delay and superluminal propagation: an electronic circuit approach , 2003, quant-ph/0302166.

[12]  Fukuro Koshiji,et al.  Equivalent Circuit Model Viewed From Receiver Side in Human Body Communication , 2019, IEEE Transactions on Biomedical Circuits and Systems.

[13]  Marjorie Skubic,et al.  Cardiovascular Function and Ballistocardiogram: A Relationship Interpreted via Mathematical Modeling , 2018, IEEE Transactions on Biomedical Engineering.

[14]  Li-Gang Wang,et al.  High fidelity of electric pulses in normal and anomalous cascaded electronic circuit systems , 2019, Results in Physics.

[15]  Yonina C. Eldar,et al.  Fundamental Distortion Limits of Analog-to-Digital Compression , 2016, IEEE Transactions on Information Theory.

[16]  Anton Pletersek,et al.  Linear Optical Encoder System With Sinusoidal Signal Distortion Below $-$60 dB , 2010, IEEE Transactions on Instrumentation and Measurement.

[17]  Blaise Ravelo,et al.  Anticipating Actuator Arbitrary Action With a Low-Pass Negative Group Delay Function , 2021, IEEE Transactions on Industrial Electronics.

[18]  Daniel E. Quevedo,et al.  Distortion Minimization in Multi-Sensor Estimation Using Energy Harvesting and Energy Sharing , 2015, IEEE Transactions on Signal Processing.

[19]  Michael Gastpar,et al.  Power, spatio-temporal bandwidth, and distortion in large sensor networks , 2005, IEEE Journal on Selected Areas in Communications.

[20]  N. Ushakov,et al.  Signal detection algorithms for interferometric sensors with harmonic phase modulation: distortion analysis and suppression. , 2017, Applied optics.

[21]  Blaise Ravelo,et al.  Similitude between the NGD function and filter gain behaviours , 2014, Int. J. Circuit Theory Appl..

[22]  Morgan W. Mitchell,et al.  NEGATIVE GROUP DELAY AND FRONTS IN A CAUSAL SYSTEM : AN EXPERIMENT WITH VERY LOW FREQUENCY BANDPASS AMPLIFIERS , 1997 .

[23]  Jeremy N. Munday,et al.  Superluminal time advance of a complex audio signal , 2004 .

[24]  B. Ravelo,et al.  First-order low-pass negative group delay passive topology , 2016 .

[25]  Ramesh Jain,et al.  Respiration rate and volume measurements using wearable strain sensors , 2019, npj Digital Medicine.

[26]  David C. Swanson,et al.  Signal Processing for Intelligent Sensor Systems with MATLAB : Signal Processing for Intelligent Sensor Systems with MATLAB , 2011 .

[27]  Morgan W. Mitchell,et al.  Causality and negative group delays in a simple bandpass amplifier , 1998 .

[28]  Blaise Ravelo,et al.  Recovery of Microwave-Digital Signal Integrity with NGD Circuits , 2013 .

[29]  S. Boll,et al.  Suppression of acoustic noise in speech using spectral subtraction , 1979 .

[30]  Jing Cheng,et al.  Design of Multi-Scale Negative Group Delay Circuit for Sensors Signal Time-Delay Cancellation , 2019, IEEE Sensors Journal.

[31]  M. Kitano,et al.  Demonstration of negative group delays in a simple electronic circuit , 2002 .

[32]  Hilmi R. Dajani,et al.  Model-Based Mean Arterial Pressure Estimation Using Simultaneous Electrocardiogram and Oscillometric Blood Pressure Measurements , 2015, IEEE Transactions on Instrumentation and Measurement.

[33]  Parisa Rashidi,et al.  Deep EHR: A Survey of Recent Advances in Deep Learning Techniques for Electronic Health Record (EHR) Analysis , 2017, IEEE Journal of Biomedical and Health Informatics.

[34]  B. Jalali,et al.  Distortion Cancellation in Time-Stretch Analog-to-Digital Converter , 2007, Journal of Lightwave Technology.

[35]  Guang-Zhong Yang,et al.  A Deep Learning Approach to on-Node Sensor Data Analytics for Mobile or Wearable Devices , 2017, IEEE Journal of Biomedical and Health Informatics.

[36]  Blaise Ravelo,et al.  Neutralization of LC- and RC-Disturbances with Left-Handed and NGD Effects , 2013 .

[37]  Chun Wei Lin,et al.  Estimating Total-Harmonic-Distortion of Analog Signal in Time-Domain , 2012, 2012 IEEE 18th International Mixed-Signal, Sensors, and Systems Test Workshop.

[38]  H. Barthelemy,et al.  Low-noise smart sensor based on silicon nanowire for MEMS resistive microphone , 2013, 2013 IEEE SENSORS.

[39]  Ryan J Halter,et al.  Design and Implementation of an Ultra-Low Resource Electrodermal Activity Sensor for Wearable Applications ‡ , 2019, Sensors.

[40]  Grzegorz Szwoch Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement , 2018, 2018 Signal Processing: Algorithms, Architectures, Arrangements, and Applications (SPA).