A capacitive biosensor for detection of staphylococcal enterotoxin B

A sensitive method for the detection of staphylococcal enterotoxin B (SEB) using a flow-injection capacitive biosensor is presented. SEB was purified from a crude culture filtrate of Staphylococcus aureus through three chromatographic steps. The first two steps were based on ion-exchange chromatography, and the last step was carried out on a gel filtration column. The SEB recovery values after the purification stages were 88%, 74%, and 12%, respectively. A horseradish peroxidase labeled antistaphylococcal enterotoxin B was prepared by the periodate method and was further employed in a sandwich-enzyme-linked immunosorbent assay (ELISA) for the determination of SEB concentrations in different samples obtained during the processing of the crude filtrate. The capacitive biosensor could detect SEB concentrations as low as 0.3 pg ml−1 with a linearity ranging from 2.8 pg ml−1 to 2.8 ng ml−1 under optimized conditions. The response time was about 10 min. A good agreement was achieved between the developed capacitive biosensor system and ELISA as a reference method for detection of SEB levels in different purification samples. The newly developed sensor has the benefits of simplicity, high sensitivity, and multiple use capability.

[1]  Sina Bavari,et al.  The evolving field of biodefence: therapeutic developments and diagnostics , 2005, Nature Reviews Drug Discovery.

[2]  Jon Cohen,et al.  Superantigens: microbial agents that corrupt immunity. , 2002, The Lancet. Infectious diseases.

[3]  Kefeng Zeng,et al.  A staphylococcal enterotoxin B magnetoelastic immunosensor. , 2004, Biosensors & bioelectronics.

[4]  T. Miyamoto,et al.  Immunomagnetic flow cytometric detection of staphylococcal enterotoxin B in raw and dry milk. , 2003, Journal of food protection.

[5]  Bo Mattiasson,et al.  Continuous measurements of a binding reaction using a capacitive biosensor. , 2005, Biosensors & bioelectronics.

[6]  Bo Mattiasson,et al.  Capacitive biosensor for detection of endotoxin , 2007, Analytical and bioanalytical chemistry.

[7]  F. Vandenesch,et al.  egc, A Highly Prevalent Operon of Enterotoxin Gene, Forms a Putative Nursery of Superantigens in Staphylococcus aureus , 2001, The Journal of Immunology.

[8]  Y. Siddiqui,et al.  Highly sensitive fluorogenic enzyme-linked immunosorbent assay: detection of staphylococcal enterotoxin B☆ , 1994 .

[9]  P. Nakane,et al.  PEROXIDASE-LABELED ANTIBODY A NEW METHOD OF CONJUGATION , 1974, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[10]  D. Gill,et al.  Bacterial toxins: a table of lethal amounts , 1982, Microbiological reviews.

[11]  K. Omoe,et al.  Detection of seg, seh, and sei genes in Staphylococcus aureus Isolates and Determination of the Enterotoxin Productivities of S. aureus Isolates Harboring seg, seh, or sei Genes , 2002, Journal of Clinical Microbiology.

[12]  J. Callahan,et al.  Detection, confirmation, and quantification of staphylococcal enterotoxin B in food matrixes using liquid chromatography--mass spectrometry. , 2006, Analytical chemistry.

[13]  Randall W. Nelson,et al.  Detection of Staphylococcal Enterotoxin B via Biomolecular Interaction Analysis Mass Spectrometry , 2003, Applied and Environmental Microbiology.

[14]  F. Ligler,et al.  Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor. , 1999, Biosensors & bioelectronics.

[15]  D R Walt,et al.  Biological warfare detection. , 2000, Analytical chemistry.

[16]  Paul M. Orwin,et al.  Exotoxins of Staphylococcus aureus. , 2000, Clinical microbiology reviews.

[17]  Raj Mutharasan,et al.  Detection and confirmation of staphylococcal enterotoxin B in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL. , 2007, Analytical chemistry.

[18]  A A Boiarski,et al.  The development of immunoassays to four biological threat agents in a bidiffractive grating biosensor. , 2000, Biosensors & bioelectronics.

[19]  Bo Mattiasson,et al.  A comparative study of capacitive immunosensors based on self-assembled monolayers formed from thiourea, thioctic acid, and 3-mercaptopropionic acid. , 2006, Biosensors & bioelectronics.

[20]  Chris A. Rowe-Taitt,et al.  Array biosensor for detection of biohazards. , 2000, Biosensors & bioelectronics.

[21]  J. McCormick,et al.  Toxic shock syndrome and bacterial superantigens: an update. , 2001, Annual review of microbiology.

[22]  G. Shen,et al.  Capacitive immunosensor for transferrin based on an o-aminobenzenthiol oligomer layer , 2002 .

[23]  Frances S Ligler,et al.  A microarray immunoassay for simultaneous detection of proteins and bacteria. , 2002, Analytical chemistry.

[24]  Jean Thioulouse,et al.  Relationships between Staphylococcus aureus Genetic Background, Virulence Factors, agr Groups (Alleles), and Human Disease , 2002, Infection and Immunity.

[25]  G. Tantillo,et al.  COMPARISON OF REVERSE PASSIVE LATEX AGGLUTINATION TEST AND IMMUNOBLOTTING FOR DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN A AND B , 2004 .

[26]  L. Peruski,et al.  Rapid and sensitive detection of biological warfare agents using time-resolved fluorescence assays. , 2002, Journal of immunological methods.

[27]  Frances S. Ligler,et al.  Biosensor Detection of Botulinum Toxoid A and Staphylococcal Enterotoxin B in Food , 2005, Applied and Environmental Microbiology.

[28]  M. Martín,et al.  Enterotoxin production and DNA fingerprinting in Staphylococcus aureus isolated from human and food samples. Relations between genetic types and enterotoxins. , 2001, International journal of food microbiology.

[29]  M. Poli,et al.  Sensitive and specific colorimetric ELISAs for Staphylococcus aureus enterotoxins A and B in urine and buffer. , 2002, Toxicon : official journal of the International Society on Toxinology.

[30]  P. Marrack,et al.  Lack of complete correlation between emetic and T-cell-stimulatory activities of staphylococcal enterotoxins , 1993, Infection and immunity.

[31]  Frances S. Ligler,et al.  Array biosensor for detection of toxins , 2003, Analytical and bioanalytical chemistry.

[32]  A. Rasooly,et al.  Surface plasmon resonance analysis of staphylococcal enterotoxin B in food. , 2001, Journal of food protection.

[33]  X. Le,et al.  Development of a tetramethylrhodamine-labeled probe for a capillary electrophoresis-based competitive immunoassay of staphylococcal enterotoxin B , 2002 .

[34]  A. Rasooly,et al.  Multitoxin biosensor-mass spectrometry analysis: a new approach for rapid, real-time, sensitive analysis of staphylococcal toxins in food. , 2000, International journal of food microbiology.

[35]  Guo-Li Shen,et al.  The integration of gold nanoparticles with semi-conductive oligomer layer for development of capacitive immunosensor , 2005 .

[36]  W. Tsai,et al.  Piezoelectric crystal immunosensor for the detection of staphylococcal enterotoxin B. , 2003, Biosensors & bioelectronics.

[37]  M. Medina Development of a fluorescent latex microparticle immunoassay for the detection of staphylococcal enterotoxin B (SEB). , 2006, Journal of agricultural and food chemistry.

[38]  J. Valdés,et al.  A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screening. , 2004, Molecular and cellular probes.