Model of the Shear Behavior of Unbonded Fiber-Reinforced Elastomeric Isolators

AbstractIn this paper, an analytical model is developed and used to predict the horizontal behavior of unbonded fiber-reinforced elastomeric isolators (FREIs). An advantageous feature of unbonded FREIs is the ability to undergo rollover due to the lack of flexural rigidity of the reinforcement and the unbonded support conditions of the isolator. The rollover causes a characteristic softening, followed by stiffening, as the initially vertical faces of the isolator come into contact with the upper and lower supports—defined as full rollover. The force-displacement relationship is modeled by dividing the isolator into three sections: a central section, which experiences pure shear, and two rollover sections, which experiences combined shear and bending. The displacements of the rollover section are used to establish the curved deformed profile and predict full rollover. The model is evaluated with experimental data from four unbonded FREI designs. A parametric study is conducted to determine the influence of...

[1]  de Michael Raaf Experimental Study of Unbonded Fiber Reinforced Elastomeric Bearings , 2009 .

[2]  Tianbo Peng,et al.  PILOT STUDY ON THE HORIZONTAL SHEAR BEHAVIOUR OF FRP RUBBER ISOLATORS , 2007 .

[3]  G. Russo,et al.  A study on experimental shear behavior of fiber-reinforced elastomeric isolators with various fiber layouts, elastomers and aging conditions , 2013 .

[4]  Dimitrios Konstantinidis,et al.  Mechanics of Rubber Bearings for Seismic and Vibration Isolation , 2011 .

[5]  James M. Kelly,et al.  Buckling load of seismic isolators affected by flexibility of reinforcement , 2005 .

[6]  James M. Kelly,et al.  Buckling of short beams with warping effect included , 2005 .

[7]  Robert G. Drysdale,et al.  Testing and modeling of square carbon fiber‐reinforced elastomeric seismic isolators , 2008 .

[8]  Robert G. Drysdale,et al.  Bonded versus unbonded strip fiber reinforced elastomeric isolators: Finite element analysis , 2011 .

[9]  J. Kelly Analysis of Fiber-Reinforced Elastomeric Isolators , 1999 .

[10]  Hamid Toopchinezhad The Performance of SU-FREIs (Stable Unbonded - Fiber Reinforced Elastomeric Isolators) , 2008 .

[11]  Andrew Douglas Barry Foster,et al.  BASE ISOLATION USING STABLE UNBONDED FIBRE REINFORCED ELASTOMERIC ISOLATORS (SU-FREI) , 2012 .

[12]  Robert G. Drysdale,et al.  Parametric Study on the Response of Stable Unbonded-Fiber Reinforced Elastomeric Isolators (SU-FREIs) , 2009 .

[13]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[14]  Hamid Toopchi-Nezhad,et al.  Stability of fiber-reinforced elastomeric bearings in an unbonded application , 2011 .

[15]  B. Shvartsman,et al.  Large deflections of a cantilever beam subjected to a follower force , 2007 .

[16]  Dimitrios Konstantinidis,et al.  Three-dimensional finite element analysis of circular fiber-reinforced elastomeric bearings under compression , 2014 .

[17]  Alfred Strauss,et al.  An innovative earthquake isolation system using fibre reinforced rubber bearings , 2008 .