Spatial versus temporal laser speckle contrast analyses in the presence of static optical scatterers

Abstract. Previously published data demonstrate that the temporal processing algorithm for laser speckle contrast imaging (LSCI) can improve the visibility of deep blood vessels and is less susceptible to static speckle artifacts when compared with the spatial algorithm. To the best of our knowledge, the extent to which the temporal algorithm can accurately predict the speckle contrast associated with flow in deep blood vessels has not been quantified. Here, we employed two phantom systems and imaging setups (epi-illumination and transillumination) to study the contrast predicted by the spatial and temporal algorithms in subsurface capillary tubes as a function of the camera exposure time and the actual flow speed. Our data with both imaging setups suggest that the contrast predicted by the temporal algorithm, and therefore the relative flow speed, is nearly independent of the degree of static optical scattering that contributes to the overall measured speckle pattern. Collectively, these results strongly suggest the potential of temporal LSCI at a single-exposure time to assess accurately the changes in blood flow even in the presence of substantial static optical scattering.

[1]  Bernard Choi,et al.  Wide-field functional imaging of blood flow and hemoglobin oxygen saturation in the rodent dorsal window chamber. , 2011, Microvascular research.

[2]  Bernard Choi,et al.  Magnetomotive laser speckle imaging. , 2010, Journal of biomedical optics.

[3]  Donald D Duncan,et al.  Detrimental effects of speckle-pixel size matching in laser speckle contrast imaging. , 2008, Optics letters.

[4]  J C Ramirez-San-Juan,et al.  Effects of speckle/pixel size ratio on temporal and spatial speckle-contrast analysis of dynamic scattering systems: Implications for measurements of blood-flow dynamics. , 2013, Biomedical optics express.

[5]  D. Boas,et al.  Laser speckle contrast imaging in biomedical optics. , 2010, Journal of biomedical optics.

[6]  C. Riva,et al.  Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. , 1972, Investigative ophthalmology.

[7]  J. Dunn,et al.  A transmissive laser speckle imaging technique for measuring deep tissue blood flow: An example application in finger joints , 2011, Lasers in surgery and medicine.

[8]  Ton van Leeuwen,et al.  Review of laser speckle contrast techniques for visualizing tissue perfusion , 2008, Lasers in Medical Science.

[9]  Bernard Choi,et al.  Laser speckle imaging for monitoring blood flow dynamics in the in vivo rodent dorsal skin fold model. , 2004, Microvascular research.

[10]  Li Zhang,et al.  Imaging cerebral blood flow through the intact rat skull with temporal laser speckle imaging. , 2006, Optics letters.

[11]  D. Durian,et al.  Speckle-visibility spectroscopy: A tool to study time-varying dynamics , 2005, cond-mat/0506081.

[12]  Bernard Choi,et al.  Quantitative, depth-resolved determination of particle motion using multi-exposure, spatial frequency domain laser speckle imaging. , 2013, Biomedical optics express.

[13]  T. Duong,et al.  Temporal statistical analysis of laser speckle images and its application to retinal blood-flow imaging. , 2008, Optics express.

[14]  M. Shirakashi,et al.  Measurement of microcirculation in the optic nerve head by laser speckle flowgraphy and scanning laser Doppler flowmetry. , 2000, American journal of ophthalmology.

[15]  J. D. Briers,et al.  Quasi real-time digital version of single-exposure speckle photography for full-field monitoring of velocity or flow fields , 1995 .

[16]  J. Briers,et al.  Flow visualization by means of single-exposure speckle photography , 1981 .

[17]  W. J. Tom,et al.  Robust flow measurement with multi-exposure speckle imaging. , 2008, Optics express.

[18]  Bernard Choi,et al.  Assessment of pulpal vitality using laser speckle imaging , 2011, Lasers in surgery and medicine.

[19]  M. Araie,et al.  Non-contact, two-dimensional measurement of tissue circulation in choroid and optic nerve head using laser speckle phenomenon. , 1995, Experimental eye research.

[20]  M. Moskowitz,et al.  Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[21]  Rolf B. Saager,et al.  Multilayer silicone phantoms for the evaluation of quantitative optical techniques in skin imaging , 2010, BiOS.

[22]  Amneet Gulati,et al.  Laser speckle imaging of atherosclerotic plaques through optical fiber bundles. , 2008, Journal of biomedical optics.

[23]  Sylvain Gioux,et al.  Wavelength optimization for rapid chromophore mapping using spatial frequency domain imaging. , 2010, Journal of biomedical optics.

[24]  Q. Luo,et al.  Modified laser speckle imaging method with improved spatial resolution. , 2003, Journal of biomedical optics.

[25]  G. Martinez-Niconoff,et al.  Simple correction factor for laser speckle imaging of flow dynamics. , 2014, Optics letters.

[26]  S. Takatani,et al.  Absolute transmitted light plethysmography for assessment of dental pulp vitality through quantification of pulp chamber hematocrit by a three-layer model. , 2008, Journal of biomedical optics.

[27]  Evan Hirst,et al.  Correction for spatial averaging in laser speckle contrast analysis , 2011, Biomedical optics express.