Respiratory-Triggered Flow-Independent Noncontrast Non-ECG-Gated MRV (REACT) Versus Contrast-Enhanced MRV for Central Venous Evaluation in Children and Young Adults: A Six-Reader Study.

Background: Contrast-enhanced MRI is commonly used to evaluate thoracic central venous patency in children and young adults. A flow-independent, noncontrast non-ECG-gated 3D MR angiography-MR venography (MRV) technique described in 2019 ["relaxation-enhanced angiography without contrast and triggering" (REACT)] may facilitate such evaluation. Objective: To compare image quality, diagnostic confidence, and interreader agreement between respiratory-triggered REACT and 3D Dixon-based contrast-enhanced MRV (CE-MRV) for evaluating thoracic central venous patency in children and young adults. Methods: This retrospective study included 42 consecutive children and young adults who underwent MRI of the neck and chest to evaluate central venous patency between August 2019 and January 2021 (median age, 5.2 years; IQR: 1.4-15.1 years; 22 female, 20 male). Examinations included respiratory-triggered REACT and navigator-gated CE-MRV sequences, based on the institution's standard-of-care protocol. Six pediatric radiologists from four different institutions independently reviewed REACT and CE-MRV sequences, assessing overall image quality (1-5; 5=excellent), diagnostic confidence (1-5; 5=extremely confident), and presence of clinically relevant artifact(s). Readers classified seven major central vessels as normal or abnormal (e.g., narrowing, thrombosis, or occlusion). Analysis used Wilcoxon signed-rank and McNemar tests, and Fleiss' kappa coefficients. Results: Distribution of overall image quality scores was higher (p=.02) for REACT than for CE-MRV for one reader (both sequences: median score, 5). Image quality was not significantly different between sequences for the remaining five readers (all p>.05). Diagnostic confidence and frequency of clinically relevant artifact(s) were not significantly different between sequences for any reader (all p>.05). Interreader agreement for vessel classification (normal vs abnormal) was similar between sequences for all seven vessels (REACT, κ=0.37-0.81; CE-MRV, κ=0.34-0.81). Pooling readers and vessels, 65.4% of vessels were normal by both sequences, 18.7% abnormal by both sequences. 9.8% abnormal by REACT only, and 6.1% abnormal by CE-MRV only. Conclusion: Respiratory-triggered REACT, in comparison with CE-MRV, demonstrated no significant difference in image quality (aside from for one of six readers), diagnostic confidence, or frequency of artifact(s), with similar interreader agreement for vessel classification as normal or abnormal. Clinical Impact: High-resolution 3D MR venography performed without IV contrast material can be used to assess central venous patency in children and young adults.

[1]  A. Faron,et al.  Free-breathing non-contrast flow-independent cardiovascular magnetic resonance angiography using cardiac gated, magnetization-prepared 3D Dixon method: assessment of thoracic vasculature in congenital heart disease , 2021, Journal of Cardiovascular Magnetic Resonance.

[2]  C. Kuhl,et al.  Relaxation-Enhanced Angiography without Contrast and Triggering (REACT) for pelvic MR venography in comparison to balanced gradient-echo and T2-weighted spin-echo techniques. , 2021, Clinical imaging.

[3]  D. Maintz,et al.  Imaging of the extracranial internal carotid artery in acute ischemic stroke: assessment of stenosis, plaques, and image quality using relaxation-enhanced angiography without contrast and triggering (REACT). , 2021, Quantitative imaging in medicine and surgery.

[4]  C. Kabbasch,et al.  Relaxation-Enhanced Angiography Without Contrast and Triggering (REACT) for Fast Imaging of Extracranial Arteries in Acute Ischemic Stroke at 3 T , 2020, Clinical Neuroradiology.

[5]  D. Maintz,et al.  Comparison of a novel Compressed SENSE accelerated 3D modified relaxation-enhanced angiography without contrast and triggering with CE-MRA in imaging of the thoracic aorta , 2020, The International Journal of Cardiovascular Imaging.

[6]  D. Maintz,et al.  Imaging of the pulmonary vasculature in congenital heart disease without gadolinium contrast: Intraindividual comparison of a novel Compressed SENSE accelerated 3D modified REACT with 4D contrast-enhanced magnetic resonance angiography , 2020, Journal of Cardiovascular Magnetic Resonance.

[7]  M. Kouwenhoven,et al.  Free-breathing non-contrast-enhanced flow-independent MR angiography using magnetization-prepared 3D non-balanced dual-echo Dixon method: A feasibility study at 3 Tesla. , 2019, Magnetic resonance imaging.

[8]  D. Podberesky,et al.  Gadolinium-based contrast agents in children , 2018, Pediatric Radiology.

[9]  David F Kallmes,et al.  Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging. , 2015, Radiology.

[10]  Martin Blaimer,et al.  Dynamically phase‐cycled radial balanced SSFP imaging for efficient banding removal , 2015, Magnetic resonance in medicine.

[11]  Satoru Morita,et al.  Unenhanced MR angiography: techniques and clinical applications in patients with chronic kidney disease. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  V. Lee,et al.  Nonenhanced MR angiography. , 2008, Radiology.

[13]  T. Grobner Gadolinium--a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? , 2006, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[14]  M. Prince Gadolinium-enhanced MR aortography. , 1990, Radiology.

[15]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[16]  T. Grist,et al.  Magnetic resonance angiography in children: technique, indications, and imaging findings , 2004, Pediatric Radiology.