Fast reconstruction of digital tomosynthesis using on-board images.

Digital tomosynthesis (DTS) is a method to reconstruct pseudo three-dimensional (3D) volume images from two-dimensional x-ray projections acquired over limited scan angles. Compared with cone-beam computed tomography, which is frequently used for 3D image guided radiation therapy, DTS requires less imaging time and dose. Successful implementation of DTS for fast target localization requires the reconstruction process to be accomplished within tight clinical time constraints (usually within 2 min). To achieve this goal, substantial improvement of reconstruction efficiency is necessary. In this study, a reconstruction process based upon the algorithm proposed by Feldkamp, Davis, and Kress was implemented on graphics hardware for the purpose of acceleration. The performance of the novel reconstruction implementation was tested for phantom and real patient cases. The efficiency of DTS reconstruction was improved by a factor of 13 on average, without compromising image quality. With acceleration of the reconstruction algorithm, the whole DTS generation process including data preprocessing, reconstruction, and DICOM conversion is accomplished within 1.5 min, which ultimately meets clinical requirement for on-line target localization.

[1]  G Panayiotakis,et al.  A multiple projection method for digital tomosynthesis. , 1992, Medical physics.

[2]  Hui Yan,et al.  Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS). , 2007, Medical physics.

[3]  B. Movsas,et al.  Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer , 2007, Physics in medicine and biology.

[4]  D. G. Grant Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.

[5]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[6]  James T. Dobbins,et al.  Optimization of matrix inverse tomosynthesis , 2001, SPIE Medical Imaging.

[7]  P. Munro,et al.  Four-dimensional cone-beam computed tomography using an on-board imager. , 2006, Medical physics.

[8]  Peter Munro,et al.  A quality assurance program for the on-board imager®. , 2006, Medical physics.

[9]  M. Oldham,et al.  Digital tomosynthesis with an on-board kilovoltage imaging device. , 2006, International journal of radiation oncology, biology, physics.

[10]  Günter Lauritsch,et al.  Theoretical framework for filtered back projection in tomosynthesis , 1998, Medical Imaging.

[11]  Hui Yan,et al.  Accelerating reconstruction of reference digital tomosynthesis using graphics hardware. , 2007, Medical physics.

[12]  Klaus Mueller,et al.  IOP PUBLISHING PHYSICS IN MEDICINE AND BIOLOGY , 2007 .

[13]  James G. Colsher,et al.  Iterative three-dimensional image reconstruction from tomographic projections , 1977 .

[14]  Mark Segal,et al.  Fast shadows and lighting effects using texture mapping , 1992, SIGGRAPH.

[15]  Fang Xu,et al.  Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware , 2005, IEEE Transactions on Nuclear Science.

[16]  James T. Dobbins,et al.  Practical strategies for the clinical implementation of matrix inversion tomosynthesis (MITS) , 2003, SPIE Medical Imaging.

[17]  Klaus Mueller,et al.  Ultra-fast 3D filtered backprojection on commodity graphics hardware , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[18]  Mark Oldham,et al.  Cone-beam-CT guided radiation therapy: A model for on-line application. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.