An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry.

BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.

[1]  S Mutic,et al.  Abutment region dosimetry for sequential arc IMRT delivery. , 1997, Physics in medicine and biology.

[2]  M Oldham,et al.  Intensity-modulated radiotherapy by means of static tomotherapy: a planning and verification study. , 1997, Medical physics.

[3]  J. Gore,et al.  Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters. , 1997, International journal of radiation oncology, biology, physics.

[4]  S. Webb The Physics of Conformal Radiotherapy: Advances in Technology , 1997 .

[5]  R Mohan,et al.  Intensity modulation optimization, lateral transport of radiation, and margins. , 1996, Medical physics.

[6]  S Webb,et al.  A method to study the characteristics of 3D dose distributions created by superposition of many intensity-modulated beams delivered via a slit aperture with multiple absorbing vanes. , 1996, Physics in medicine and biology.

[7]  I. Das,et al.  Dosimetry of high energy photon and electron beams with CEA films. , 1996, Medical physics.

[8]  J C Gore,et al.  Radiation therapy dosimetry using magnetic resonance imaging of polymer gels. , 1996, Medical physics.

[9]  A R Bleier,et al.  The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation. , 1996, International journal of radiation oncology, biology, physics.

[10]  B. Balcom,et al.  Diffusion in Fe(II/III) radiation dosimetry gels measured by magnetic resonance imaging. , 1995, Physics in medicine and biology.

[11]  M Oldham,et al.  The optimization and inherent limitations of 3D conformal radiotherapy treatment plans of the prostate. , 1995, The British journal of radiology.

[12]  Clinical realization of 3D conformal intensity modulated radiotherapy: regarding Bortfeld et al., IJROBP 30:899-908; 1994. , 1995, International journal of radiation oncology, biology, physics.

[13]  Mark P. Carol,et al.  Peacock™: A system for planning and rotational delivery of intensity‐modulated fields , 1995, Int. J. Imaging Syst. Technol..

[14]  J C Gore,et al.  Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.

[15]  J. Gore,et al.  NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. , 1993, Magnetic resonance imaging.

[16]  M A Astrahan,et al.  Algorithm for dosimetry of multiarc linear-accelerator stereotactic radiosurgery. , 1991, Medical physics.