Pulse arrival time accurately detects pacing-induced mechanical alternans

Accurate cardiac risk stratification is crucial for preventing cardiac death, but still remains an unmet need. Mechanical alternans (MA), an oscillation of blood pressure that occurs on a beat-to-beat basis, has been recognized as a marker of cardiac instability and is associated with an increased risk of cardiac death. However, the use of MA for risk stratification is currently limited by the invasiveness and costs of continuous blood pressure monitoring. A non-invasive, cuffless and affordable method to detect MA is therefore highly desirable. The pulse transit time (PTT) and the pulse arrival time (PAT) are promising techniques for continuous blood pressure monitoring, particularly for detecting short-term blood pressure changes. In this work, we hypothesized that PAT, measured as the interval between the R-wave in the ECG and a distal arterial pulse, can be used to accurately track fast beat-to-beat blood pressure dynamics and detect MA. A total of 42 ECG and femoral arterial pressure recordings from 12 patients with normal ventricles were analyzed. Patients were instructed to breath at a fixed respiratory rate and MA was induced by ventricular pacing. Both MA and PAT alternans were detected using spectral analysis. MA was present in 69% of blood pressure recordings (n=29). ROC analysis showed that PAT accurately detected MA, with an area under the curve was equal to AUC = 0.94. The optimal threshold for detecting MA by using PAT provided 90% sensitivity and 85% specificity. In conclusion, this study demonstrates that PAT can be used to accurately detect pacing-induced MA and may represent a first step toward non-invasive, cuff-less and affordable MA screening for cardiac risk assessment.

[1]  Henggui Zhang,et al.  Cyclical modulation of human ventricular repolarization by respiration , 2012, Front. Physio..

[2]  Juan Pablo Martínez,et al.  Microvolt T-wave alternans physiological basis, methods of measurement, and clinical utility--consensus guideline by International Society for Holter and Noninvasive Electrocardiology. , 2011, Journal of the American College of Cardiology.

[3]  Ben Hanson,et al.  Effect of autonomic blocking agents on the respiratory-related oscillations of ventricular action potential duration in humans , 2015, American journal of physiology. Heart and circulatory physiology.

[4]  Juan Pablo Martínez,et al.  Methodological principles of T wave alternans analysis: a unified framework , 2005, IEEE Transactions on Biomedical Engineering.

[5]  A. Steptoe,et al.  Pulse wave velocity as a measure of blood pressure change. , 1976, Psychophysiology.

[6]  Kevin Burrage,et al.  In Vivo and In Silico Investigation Into Mechanisms of Frequency Dependence of Repolarization Alternans in Human Ventricular Cardiomyocytes , 2016, Circulation research.

[7]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[8]  Heather T. Ma,et al.  Spectral Analysis of Pulse Transit Time Variability and Its Coherence with Other Cardiovascular Variabilities , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Violeta Monasterio,et al.  Comparative Evaluation of Methodologies for T-Wave Alternans Mapping in Electrograms , 2014, IEEE Transactions on Biomedical Engineering.

[10]  Guanqun Zhang,et al.  Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. , 2011, Journal of applied physiology.

[11]  J Thomas Bigger,et al.  Microvolt T-Wave Alternans Distinguishes Between Patients Likely and Patients Not Likely to Benefit From Implanted Cardiac Defibrillator Therapy: A Solution to the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II Conundrum , 2004, Circulation.

[12]  C. Malloy,et al.  Clinical and hemodynamic characteristics of patients with inducible pulsus alternans. , 1988, American heart journal.

[13]  J. Madias Letters regarding article by Bloomfield et al, "microvolt T-wave alternans distinguishes between patients likely and patients not likely to benefit from implanted cardiac defibrillator therapy". , 2005, Circulation.

[14]  E. Braunwald,et al.  Studies on Starling's Law of the Heart: VI. Relationships between Left Ventricular End‐Diastolic Volume and Stroke Volume in Man with Observations on the Mechanism of Pulsus Alternans , 1962, Circulation.

[15]  W P Miller,et al.  End-systolic pressure-diameter relationships during pulsus alternans in intact pig hearts. , 1986, The American journal of physiology.

[16]  D. Rosenbaum,et al.  Cellular mechanisms of arrhythmogenic cardiac alternans. , 2008, Progress in biophysics and molecular biology.