Direct torque control schemes for split-phase induction machine

In this paper, DTC (direct torque control) algorithms for split-phase induction machine (SPIM) are established. SPIM has two sets of three-phase stator windings, with a shift of thirty electrical degrees between them. The significant contributions of the present work are: a) two new methods of DTC technique for SPIM are developed. They are called as resultant flux control method and individual flux control method, b) advantages and disadvantages of both the methods are discussed. High torque ripple is a disadvantage for three-phase DTC. It is found that torque ripple in SPIM could be significantly reduced without increasing the switching frequency.