A review of magnetically controlled shunt reactor for power quality improvement with renewable energy applications

Renewable energy sources are widely available on Earth; hence they have attracted much interest in both research and practical applications. In the large scale renewable energy system, power quality into the grid, especially harmonics and flicker, impacts on grid system significantly. In recent years, magnetically controlled shunt reactors (MCSRs) have been widely used to solve the problems of the power quality caused a failure or malfunction of the end-user equipment. MCSR can simplify the system reactive power and voltage control in the super / special high-voltage power grid, suppress power frequency and operation over voltage, eliminating generator self excitation, dynamically compensate charging the power in a transmission line, suppress the secondary arc current, damping system resonance and so on, which can meet the various needs of the system, it has a very broad application prospects. This paper presents a comprehensive review of MCSR configurations, the control strategies, the selection of components, other related economic and technical considerations, and their selection for specific applications. It is aimed at providing a broad perspective on the status of MCSR technology to the researchers and the application engineers dealing with power quality issues. A list of more than 130 research publications on the subject is also appended for a quick reference.

[1]  G.W. Chang,et al.  Modeling ${\rm SF}_{6}$ Circuit Breaker for Characterizing Shunt Reactor Switching Transients , 2007, IEEE Transactions on Power Delivery.

[2]  Romualds Bogdanovics,et al.  Dual model of single-winding magnetically Controlled Shunt Reactor , 2014, 2014 IEEE 2nd Workshop on Advances in Information, Electronic and Electrical Engineering (AIEEE).

[3]  Z.Q. Wang,et al.  Study on controllable reactor magnetic structure and loss based on ANSYS , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[4]  Yu Zhang,et al.  A novel controllable reactor of transformer type , 2008, 2008 International Conference on Electrical Machines and Systems.

[5]  Om Prakash Mahela,et al.  A critical review of detection and classification of power quality events , 2015 .

[6]  Baichao Chen,et al.  A Novel Control Method for Magnetic-Valve Controllable Reactor , 2009, 2009 First International Workshop on Database Technology and Applications.

[7]  M. Brenna,et al.  A New Proposal for Power Quality and Custom Power Improvement: OPEN UPQC , 2009, IEEE Transactions on Power Delivery.

[8]  Guoqiang Zhang,et al.  Simulation Analysis of Control System in an Innovative Magnetically-Saturated Controllable Reactor , 2014 .

[9]  Wenjie Li,et al.  Research of reactive power and voltage integrated control in substation based on new type SVC , 2012, 2012 Power Engineering and Automation Conference.

[10]  M. Castilla,et al.  Effects of harmonic distortion of the supply voltage on the optimum performance of a thyristor controlled reactor-type compensator , 1994 .

[11]  Wei-jie Zheng,et al.  Adaptive tracking algorithm for magnetically controlled shunt reactor control , 2010, 2010 International Conference on Power System Technology.

[12]  Yifan Wang,et al.  A novel control algorithm for magnetically controlled reactor , 2014, ISIE.

[13]  G. Trudel,et al.  A 735 kV shunt reactors automatic switching system for Hydro-Quebec network , 1996 .

[14]  Baichao Chen,et al.  Investigation on Harmonics Suppression of Saturable Magnetically Controlled Reactor Using Nonlinear Magnetic Field Analysis , 2012, 2012 Sixth International Conference on Electromagnetic Field Problems and Applications.

[15]  Yaozhong Liu,et al.  Modeling and Harmonic Optimization of a Two-Stage Saturable Magnetically Controlled Reactor for an Arc Suppression Coil , 2012, IEEE Transactions on Industrial Electronics.

[16]  Chen Guozhu,et al.  A novel control algorithm for magnetically controlled reactor , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[17]  Bin Zheng,et al.  Secondary Arc Current Analysis of an Untransposed EHV/UHV Transmission Line With Controllable Unbalanced Shunt Reactor , 2015, IEEE Transactions on Power Delivery.

[18]  Julio Barros,et al.  A review of measurement and analysis of electric power quality on shipboard power system networks , 2016 .

[19]  Jiaxin Yuan,et al.  Modeling and Simulation of the Multi-stage Saturable Magnetically Controlled Reactor with Very Low Harmonics , 2013 .

[20]  Takanori Isobe,et al.  Full-Bridge Reactive Power Compensator With Minimized-Equipped Capacitor and Its Application to Static Var Compensator , 2016, IEEE Transactions on Power Electronics.

[21]  J. D. Ainsworth Phase-locked oscillator control system for thyristor-controlled reactors , 1988 .

[22]  Baodong Bai,et al.  Study on main magnetic field of ultra-high voltage magnetically controlled saturated reactor , 2014, 2014 17th International Conference on Electrical Machines and Systems (ICEMS).

[23]  M. Davies,et al.  Static VAr compensator (STATCOM) based on single-phase chain circuit converters , 1998 .

[24]  Ji Yanchao,et al.  Novel Harmonic Free Single Phase Variable Inductor Based on Active Power Filter Strategy , 2006, 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference.

[25]  Baichao Chen,et al.  A Novel Induction Motor Soft Starter Based on Magnetically Controlled Reactor , 2006, 2006 1ST IEEE Conference on Industrial Electronics and Applications.

[26]  Zhenbao Zhu,et al.  The Application of MSVC Reactive Power Compensation Device to the High Voltage Power Supply of Coal Mine , 2008 .

[27]  Wang Jin,et al.  Design principles of magnetically controlled reactor , 2001, ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501).

[28]  Jiaxin Yuan,et al.  Electrical magnetic hybrid power quality compensation system for V/V traction power supply system , 2016 .

[29]  E. Acha,et al.  Harmonic modelling in Hartley's domain with particular reference to three phase thyristor-controlled reactors , 1997 .

[30]  Tadashi Koshizuka,et al.  Application of controlled switching to 500 kV shunt reactor current interruption , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[31]  Jun Wang,et al.  Reactive power-voltage integrated control method based on MCR , 2010, 2010 11th International Conference on Control Automation Robotics & Vision.

[32]  Robert H. Lasseter,et al.  Stability and harmonics in thyristor controlled reactors , 1989 .

[33]  R. Escarela-Perez,et al.  Temperature Reduction in the Clamping Bolt Zone of Shunt Reactors: Design Enhancements , 2014, IEEE Transactions on Power Delivery.

[34]  Dongsheng Yuan,et al.  Winding Current Utilization Calculation of Controllable Reactor of Transformer Type Based on Equivalent Leakage Reactance , 2014, IEEE Transactions on Applied Superconductivity.

[35]  Peng Wang,et al.  MSVC based multi-side coordinated reactive compensation capacity configuration and voltage/var control in substation , 2014, 2014 9th IEEE Conference on Industrial Electronics and Applications.

[36]  Robert H. Lasseter,et al.  Harmonic Interactions in Thyristor Controlled Reactor Circuits , 1989, IEEE Power Engineering Review.

[37]  K. Hirasawa,et al.  High-frequency reignition current and its influence on electrical durability of circuit breakers associated with shunt-Reactor current switching , 2004, IEEE Transactions on Power Delivery.

[38]  Om Prakash Mahela,et al.  Topological aspects of power quality improvement techniques: A comprehensive overview , 2016 .

[39]  M. Grady,et al.  Power quality indices for transient disturbances , 2006, 2006 IEEE Power Engineering Society General Meeting.

[40]  N. Jenkins,et al.  Mathematical models of a three-level advanced static VAr compensator , 1997 .

[41]  A. T. Johns,et al.  Performance of distance protection of e.h.v. feeders utilising shunt - reactor arrangements for arc suppression and voltage control , 1980 .

[42]  Liang Yan-ping,et al.  Leakage inductance calculation and simulation research of extra-high voltage magnetically controlled shunt reactor , 2010, 2010 International Conference on Mechanic Automation and Control Engineering.

[43]  Maria Dolores Gil Montoya,et al.  Power quality techniques research worldwide: A review , 2016 .

[44]  A. Baggini,et al.  Power quality , 2004, Proceedings. 2004 First International Conference on Power Electronics Systems and Applications, 2004..

[45]  Jiaxin Yuan,et al.  An electrical-magnetic hybrid power quality compensation strategy for V/V traction power supply system , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[46]  Yi Liu,et al.  Adaptive Backstepping Sliding Mode $H_{\infty} $ Control of Static Var Compensator , 2011, IEEE Transactions on Control Systems Technology.

[47]  E. W. Kimbark Suppression of Ground-Fault Arcs on Single-Pole-Switched EHV Lines by Shunt Reactors , 1964 .

[48]  Jeyabalan Velandy Vector space representation of signals for transient signal analysis in transformers and shunt reactor , 2016 .

[49]  Ali Ajami,et al.  A Multi-Objective HBMO-Based New FC-MCR Compensator for Damping of Power System Oscillations , 2007 .

[50]  Wei Wang,et al.  Electromagnetic Interference Analysis in HV Substation Due to a Static Var Compensator Device , 2012, IEEE Transactions on Power Delivery.

[51]  Yongfeng Zhang,et al.  Research on Turn Ratio of Magnetic Valve Type Controlled Reactor Based on Bifurcation Theory , 2009, 2009 Ninth International Conference on Hybrid Intelligent Systems.

[52]  Zheng Weijie The dynamic harmonics characteristics research of Extra/Ultra high voltage magnetically controlled shunt reactor , 2012 .

[53]  Juan Dixon,et al.  Static Var Compensator and Active Power Filter with Power Injection Capability, Using 27-level Inverters and Photovoltaic Cells , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[54]  Qingfu Li,et al.  Calculation of current-limiting reactors and simulation analysis of a controllable reactor of transformer type , 2003, Sixth International Conference on Electrical Machines and Systems, 2003. ICEMS 2003..

[55]  C. J. Melhorn,et al.  Interpretation and analysis of power quality measurements , 1995 .

[56]  Chia-Hung Lin,et al.  Adaptive wavelet networks for power-quality detection and discrimination in a power system , 2006 .

[57]  Yisong Zhao,et al.  Study on A Novel Controllable Reactor Using in Ultra-high Voltage System , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[58]  Guozhu Chen,et al.  A novel Continuously Adjustable Magnetic-valve Controllable Reactor and its modeling , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[59]  C. Sankaran Power Quality , 2001 .

[60]  D. L. Osborn,et al.  Control system design and performance verification for the Chester, Maine static VAr compensator , 1992 .

[61]  A. Bryantsev,et al.  Power compensators based on magnetically controlled shunt reactors in electric networks with a voltage between 110 kV and 500 kV , 2010, 2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA).

[62]  Xianzhong Duan,et al.  A hybrid controllable shunt reactor of transformer type , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[63]  Xiaobo Yang,et al.  Orthogonal flux controllable reactor for transmission lines , 2010, 2010 International Conference on Power System Technology.

[64]  Ming Xing Tian,et al.  Different short-circuit impedance calculation method of controllable reactor of transformer type , 2013, 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices.

[65]  Li Liyi,et al.  Research on DC magnetic flux controllable reactor , 2008, 2008 International Conference on Electrical Machines and Systems.

[66]  Wei Xu,et al.  The simulation of the controllable reactor and it's application in Ultra High Voltage Transmission Lines , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[67]  T. Zheng,et al.  Microprocessor-based protection scheme for high-voltage magnetically controlled shunt reactors , 2014 .

[68]  C. R. Fuerte-Esquivel,et al.  Advanced three-phase static VAr compensator models for power flow analysis , 2003 .

[69]  Shigemitsu Okabe,et al.  Investigations of multiple reignition phenomena and protection scheme of shunt reactor current interruption in GIS substations , 1993 .

[70]  A. McEachern,et al.  Designing electronic devices to survive power-quality events , 2000 .

[71]  Ian Dobson,et al.  Switching time bifurcations in a thyristor controlled reactor , 1996 .

[72]  R. Yacamini,et al.  Thyristor controlled reactors as harmonic sources in HVDC converter stations and AC systems , 1986 .

[73]  Xiangzheng Xu Research on Magnetic Valve Structure Optimization of MagneticControlled Reactor , 2014 .

[74]  Xiangzheng Xu Research on Fast Response Characteristic of Magnetic Control Reactor , 2014 .

[75]  G.K. Venayagamoorthy,et al.  Dual-Function Neuron-Based External Controller for a Static Var Compensator , 2008, IEEE Transactions on Power Delivery.

[76]  Wei Xing Zheng,et al.  Offset-Free Nonlinear MPC for Mismatched Disturbance Attenuation With Application to a Static Var Compensator , 2014, IEEE Transactions on Circuits and Systems II: Express Briefs.

[77]  Tao Zheng,et al.  Analysis on the effects of energization mode for magnetically controlled shunt reactor , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[78]  Abbas Lotfi,et al.  Design Optimization of Gapped-Core Shunt Reactors , 2012, IEEE Transactions on Magnetics.

[79]  Yucheng Zhang,et al.  Analysis on practical design of virtual-air-gap variable reactors for tieline reclosing in microgrid , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[80]  Zuquan Liang,et al.  The application and research of MCR in substation reactive power compensation , 2015, 2015 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE).

[81]  Qingfu Li,et al.  An equivalent circuit and simulation analysis of magnetically-saturated controllable reactors , 2003, Sixth International Conference on Electrical Machines and Systems, 2003. ICEMS 2003..

[82]  Tian Cuihua,et al.  Fast Response Research of Magnetically Controlled Reactor , 2015 .

[83]  Mingxing Tian,et al.  A controllable reactor of transformer type , 2004, IEEE Transactions on Power Delivery.

[84]  Jianning Yin,et al.  Magnetic Integration Technology in Controllable Reactor of Transformer Type Constituted by Various Magnetic Materials , 2014, IEEE Transactions on Applied Superconductivity.

[85]  Chenguo Yao,et al.  Noninvasive method for online detection of internal winding faults of 750 kV EHV shunt reactors , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[86]  Luiz A. C. Lopes,et al.  An efficient switched-reactor-based static VAr compensator , 1994 .

[87]  Dong Sheng Yuan,et al.  Analysis of two kinds of integrated magnetic structure of controllable reactor of transformer type , 2013, 2013 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices.

[88]  Lianguang Liu,et al.  Research on the applications of differential protection in TCT controllable shunt reactor , 2015, 2015 IEEE Power & Energy Society General Meeting.

[89]  Baichao Chen,et al.  Modeling and characteristics research on EHV magnetically controlled reactor , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[90]  Wagih Z. Fam Measurement of transformer and shunt reactor load losses using a pointing vector probe , 1989 .

[91]  Zhang Hai-ting,et al.  The 500kV MCSR modeling and steady-state characteristics analysis , 2011, 2011 International Conference on Electrical Machines and Systems.

[92]  Thomas J. Dionise Assessing the Performance of a Static Var Compensator for an Electric Arc Furnace , 2014 .

[93]  A. Domijan,et al.  On power quality indices and real time measurement , 2005, IEEE Transactions on Power Delivery.

[94]  Li Wang,et al.  Suppression of common torsional mode interactions using shunt reactor controllers , 1993 .

[95]  Ronald G. Harley,et al.  Performance of a shunt reactor controller with non-identical parallel turbogenerators , 1991 .

[96]  Zhang Xing,et al.  Inverse-Hyperbolic Dynamic Model for Extra and Ultra Voltage Magnetically Controlled Shunt Reactor , 2010, 2010 International Conference on Electrical and Control Engineering.

[97]  J. Avila-Montes,et al.  A Novel Compensation Scheme Based on a Virtual Air Gap Variable Reactor for AC Voltage Control , 2014, IEEE Transactions on Industrial Electronics.

[98]  Shiun Chen Open design of networked power quality monitoring systems , 2004, IEEE Transactions on Instrumentation and Measurement.

[99]  I. Hunter,et al.  Power quality issues-a distribution company perspective , 2001 .

[100]  M. Kezunovic,et al.  Integrated Fault Location and Power-Quality Analysis in Electric Power Distribution Systems , 2016, IEEE Transactions on Power Delivery.

[101]  Wang Fengxiang,et al.  Modeling and characteristics of a novel magnet saturation controllable reactor , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[102]  Hai Wang,et al.  A Simple and Practical Double Fast Excitation Circuit of Magnetic Control Reactor , 2015 .

[103]  Qing Yang,et al.  Field Experiments on Overvoltage Caused by 12-kV Vacuum Circuit Breakers Switching Shunt Reactors , 2016, IEEE Transactions on Power Delivery.

[104]  Liu Hong,et al.  Research on voltage regulation of magnetic valve controlled reactor based on thyristor , 1998, POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).

[105]  Li Peng,et al.  Research of magnetically controlled reactor simulation model and its experiments , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[106]  A. Teke,et al.  A Novel Reference Signal Generation Method for Power-Quality Improvement of Unified Power-Quality Conditioner , 2011, IEEE Transactions on Power Delivery.

[107]  R. R. Karymov,et al.  Comparison of magnetically controlled reactor (MCR) and thyristor controlled reactor (TCR) from harmonics point of view , 2006 .

[108]  Sheng-jie Gu,et al.  Study on Arrangement of Harmonic-suppressed Winding of Controllable Reactor of Transformer Type , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[109]  M. M. Morcos,et al.  Artificial Intelligence and Advanced Mathematical Tools for Power Quality Applications: A Survey , 2001, IEEE Power Engineering Review.

[110]  S.V. Smolovik,et al.  Steady-state and transient stability of 500 kV long-distance AC transmission lines with magnetically controlled shunt reactors , 2005, 2005 IEEE Russia Power Tech.

[111]  Toyoji Himei,et al.  Design procedure of firing angles for harmonic reduction in a thyristor-controlled reactor by asymmetrical firing control , 1985 .

[112]  Dale R. Patrick,et al.  Electrical Distribution Systems , 1998 .

[113]  Sam Morello,et al.  Comprehensive analysis to specify a static var compensator for an Electric Arc Furnace upgrade , 2014, 2014 IEEE Industry Application Society Annual Meeting.

[114]  Kai Feng,et al.  Characteristics of the magnetic energy recovery switch as a static Var compensator technology , 2015 .

[115]  M.H. Abdel-Rahman,et al.  New static var compensator control strategy and coordination with under-load tap changer , 2006, IEEE Transactions on Power Delivery.

[116]  Maria Makarova,et al.  Dual scheme based mathematical modeling of Magnetically Controlled Shunt Reactors 6–500 kV , 2012, 2012 Electric Power Quality and Supply Reliability.

[117]  Zaibin Jiao,et al.  A Novel Single-Phase Adaptive Reclosure Scheme for Transmission Lines With Shunt Reactors , 2009, IEEE Transactions on Power Delivery.

[118]  Kamal Al-Haddad,et al.  A Combination of Shunt Hybrid Power Filter and Thyristor-Controlled Reactor for Power Quality , 2014, IEEE Transactions on Industrial Electronics.

[119]  Yanchao Ji,et al.  Novel four-bridge PWM static VAr compensator , 1997 .

[120]  Tao Zheng,et al.  Design and Analysis on the Turn-to-Turn Fault Protection Scheme for the Control Winding of a Magnetically Controlled Shunt Reactor , 2015, IEEE Transactions on Power Delivery.

[121]  Xiangzheng Xu The status and development of magnetically controlled reactor , 2009, 2009 International Conference on Test and Measurement.

[122]  Tian Ming Xing,et al.  Harmonic Characteristic Analysis of Magnetically Saturation Controlled Reactor , 2013 .

[123]  Tetsuya Yamamoto,et al.  Voltage Control of Self-Excited Induction Generators using a Three- Phase Magnetic Flux Controlled Type Variable Reactor , 2012 .

[124]  A. Mohamed,et al.  PSCAD/EMTDC simulation of unified series-shunt compensator for power quality improvement , 2005, IEEE Transactions on Power Delivery.

[125]  E. Hiraki,et al.  Terminal voltage regulation characteristics by static var compensator for a three-phase self-excited induction generator , 2004, IEEE Transactions on Industry Applications.

[126]  Bin Sun,et al.  A Novel Neutral Electromagnetic Hybrid Flexible Grounding Method in Distribution Networks , 2017, IEEE Transactions on Power Delivery.

[127]  Aurelio García-Cerrada,et al.  Comparison of thyristor-controlled reactors and voltage-source inverters for compensation of flicker caused by arc furnaces , 2000 .

[128]  Mahmoud Ebadian,et al.  Performance Comparison of Transient Behaviors of Magnetically and Thyristor-controlled Reactors , 2009 .

[129]  Božidar Filipović-Grčić,et al.  Transients caused by switching of 420 kV three-phase variable shunt reactor , 2016 .

[130]  Wang Peng,et al.  MSVC based multi-side coordinated reactive compensation capacity configuration and voltage/var control in substation , 2014, ICIEA 2014.

[131]  N.D. Hatziargyriou,et al.  Control of shunt reactor inrush currents in the Hellenic-Interconnected Power System , 2005, IEEE Transactions on Power Delivery.

[132]  L.A.S. Pilotto,et al.  Thyristor-Controlled Reactors Nonlinear and Linear Dynamic Analytical Models , 2008, IEEE Transactions on Power Delivery.

[133]  Magne Runde,et al.  Wideband Modeling, Field Measurement, and Simulation of a 420-kV Variable Shunt Reactor , 2015, IEEE Transactions on Power Delivery.

[134]  Rahim Zeinali,et al.  A multi-objective model for allocation of Magnetically Controlled Shunt Reactors , 2015, 2015 IEEE 8th GCC Conference & Exhibition.

[135]  Weijie Zheng Compound flexible control strategy for magnetically controlled shunt reactor suppressing overvoltage , 2014, 2014 China International Conference on Electricity Distribution (CICED).

[136]  Jin Li,et al.  Determination of the number of turns and voltage of control winding of controllable reactor of transformer type , 2015, 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD).