Application considerations for class-1 div-2 inverter-fed motors

Application considerations for fixed-speed motors utilized in hazardous locations are not new to the electrical community and have been discussed previously and are relatively well known in the petroleum industry. Documented guidelines for these applications are currently established, are primarily centered on motor-temperature-rise limitations and the use of nonsparking fans in class-1 division-2/zone-2 locations. However, there are additional considerations when motors and their associated loads are on inverter supply. Items such as the effect on motor temperature rise when operating at reduced speeds for units without independently powered blowers, the effect of nonsinusoidal supply at the motor terminals on motor temperature rise as well as rotor voltage related phenomenon are relevant items. This paper identifies and provides guidelines particular to inverter-fed applications for class-1 division-2 installations.

[1]  Doyle F. Busse,et al.  System electrical parameters and their effects on bearing currents , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[2]  Benjamin M. Wu,et al.  A novel power factor control scheme for high power GTO current source converter , 1996 .

[3]  J. H. Dymond Sparking electrical discharge and heating in synchronous and induction machines: Can it be controlled? , 1997, Record of Conference Papers. IEEE Industry Applications Society 44th Annual Petroleum and Chemical Industry Conference.

[4]  Russel J. Kerkman,et al.  EMI emissions of modern PWM AC drives , 1999 .

[5]  J. DiPaola,et al.  The selection of motors in hazardous atmospheres and hostile environments. A theoretical and practical guide , 1997, Record of Conference Papers. IEEE Industry Applications Society 44th Annual Petroleum and Chemical Industry Conference.

[6]  R.L. Doughty,et al.  Safe application of totally enclosed motors in hazardous Class I, Division 2 locations , 1993, Industry Applications Society 40th Annual Petroleum and Chemical Industry Conference.

[7]  R. L. Doughty,et al.  Evaluation of maximum rotor temperatures in TEFC inverter-fed motors , 2000, Record of Conference Papers. Industry Applications Society Forty-Seventh Annual Conference. 2000 Petroleum and Chemical Industry Technical Conference (Cat. No.00CH37112).

[8]  P. Regan,et al.  Solutions for MV motors and generators in hazardous locations , 1996, Proceedings of 1996 IAS Petroleum and Chemical Industry Technical Conference.

[9]  D.C. Mohla,et al.  Risk of ignition due to transition currents in medium voltage motors for classified locations , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[10]  R. L. Doughty,et al.  Flammable vapor ignition initiated by hot rotor surfaces within an induction motor-reality or not? , 1997, Record of Conference Papers. IEEE Industry Applications Society 44th Annual Petroleum and Chemical Industry Conference.

[11]  P. J. Link,et al.  Minimizing electric bearing currents in ASD systems , 1999 .

[12]  R. L. Haynes,et al.  Motors for use in hazardous areas: a review of requirements and current practices , 1991, Industry Applications Society 38th Annual Petroleum and Chemical Industry Conference.

[13]  Fei Wang,et al.  Motor shaft voltages and bearing currents and their reduction in multi-level medium voltage PWM voltage source inverter drive applications , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[14]  Yuan Xiao,et al.  A new current source converter using a symmetric gate commutated thyristor (SGCT) , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[15]  Yuan Xiao,et al.  Medium voltage drives: are isolation transformers required? , 2002, Record of Conference Papers. Industry Applications Society. Forty-Ninth Annual Conference. 2002 Petroleum and Chemical Industry Technical Conference.

[16]  R. Schiferl,et al.  Circuit model for shaft voltage prediction in induction motors fed by PWM-based AC drives , 2003 .

[17]  F. Lienesch,et al.  Converter-fed motors for use in potentially explosive atmospheres , 2002, Record of Conference Papers. Industry Applications Society. Forty-Ninth Annual Conference. 2002 Petroleum and Chemical Industry Technical Conference.

[18]  Bin Wu,et al.  Medium voltage motor harmonic heating, torques and voltage stress when applied on VFDs , 1996, Proceedings of 1996 IAS Petroleum and Chemical Industry Technical Conference.

[19]  M. J. Melfi,et al.  Inverter driven induction motor bearing current solutions , 2002, Record of Conference Papers. Industry Applications Society. Forty-Ninth Annual Conference. 2002 Petroleum and Chemical Industry Technical Conference.

[20]  Prasad Enjeti,et al.  Analysis of common mode voltage-"neutral shift" in medium voltage PWM adjustable speed drive (MV-ASD) systems , 2000 .