Electron detection characteristics of a slow‐scan CCD camera, imaging plates and film, and electron image restoration

Electron detection characteristics are summarized for the slow scan CCD (SSC) camera, imaging plates, and film. The advantage of each detector is demonstrated with the selected examples of electron diffraction and imaging. The Richardson‐Lucy algorithm for image restoration is described and tested for images recorded with the SSC camera. The effectiveness of image restoration is demonstrated for the recorded high‐resolution lattice image, energy‐loss spectrum, and convergent beam electron diffraction (CBED) pattern. Microsc. Res. Tech. 49:245–268, 2000. © 2000 Wiley‐Liss, Inc.

[1]  K. Herrmann,et al.  Performance of electron image converters with YAG single-crystal screen and CCD sensor , 1991 .

[2]  Kenneth H. Downing,et al.  Analysis of photographic emulsions for electron microscopy of two-dimensional crystalline specimens , 1982 .

[3]  M. Sonoda,et al.  Computed radiography utilizing scanning laser stimulated luminescence. , 1983, Radiology.

[4]  R. Schröder,et al.  A new quasi-confocal image plate scanner with improved spatial resolution and ideal detection efficiency , 1994 .

[5]  W. Ruijter,et al.  Methods to measure properties of slow‐scan CCD cameras for electron detection , 1992 .

[6]  K. Ishizuka Analysis of electron image detection efficiency of slow-scan CCD cameras , 1993 .

[7]  M. Hahn Properties of Commercial Films for Electron Microscopy , 1980 .

[8]  Yoshiyuki Amemiya,et al.  A new type of X-ray area detector utilizing laser stimulated luminescence , 1986 .

[9]  D. Shindo,et al.  Sensitivity and Fading Characteristics of the 25 μm Pixel Size Imaging Plate for Transmission Electron Microscopes , 1996 .

[10]  William H. Richardson,et al.  Bayesian-Based Iterative Method of Image Restoration , 1972 .

[11]  Yoshihiko Kanemitsu,et al.  Mechanism of photostimulated luminescence in BaFX:Eu2+ (X=Cl,Br) phosphors , 1984 .

[12]  Jian-Min Zuo,et al.  Large dynamic range, parallel detection system for electron diffraction and imaging , 1988 .

[13]  J. Zuo,et al.  Performance of imaging plates for electron recording , 1996 .

[14]  P. Jansson Deconvolution of images and spectra (2nd ed.) , 1996 .

[15]  M H Ellisman,et al.  High-sensitivity lens-coupled slow-scan CCD camera for transmission electron microscopy. , 1993, Ultramicroscopy.

[16]  W. Ruijter Imaging properties and applications of slow-scan charge-coupled device cameras suitable for electron microscopy , 1995 .

[17]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[18]  J Brink,et al.  Performance of a slow-scan CCD camera for macromolecular imaging in a 400 kV electron cryomicroscope. , 1996, Micron.

[19]  Y. Harada,et al.  Development of the imaging plate for the transmission electron microscope and its characteristics , 1990 .

[20]  Takuya Kobayashi,et al.  A comparative study of the modulation transfer function of an imaging plate , 1992 .

[21]  J. Zuo,et al.  Accurate Measurements of Crystal Structure Factors Using a FEG Electron Microscope , 1997 .

[22]  Joachim Mayer,et al.  Quantitative characterization of point spread function and detection quantum efficiency for a YAG scintillator slow scan CCD camera , 1995 .

[23]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[24]  D. Krahl,et al.  Performance of a low-noise CCD camera adapted to a transmission electron microscope , 1992 .

[25]  J. Zuo,et al.  Ultramicroscopy Letter Electron detection characteristics of slow-scan CCD camera , 1996 .

[26]  E. Zeitler The photographic emulsion as analog recorder for electrons , 1992 .

[27]  R. White,et al.  Image recovery from data acquired with a charge-coupled-device camera. , 1993, Journal of the Optical Society of America. A, Optics and image science.