A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy

PurposeDescription of a novel method for evaluation of pedicle screws in 3 dimensions utilizing O-arm® and StealthStation® navigation; identifying sources of error, and pearls for more precise screw placement.MethodsO-arm and StealthStation navigation were utilized to place pedicle screws. Initial and final O-arm scans were performed, and the projected pedicle probe track, projected pedicle screw track, and final screw position were saved for evaluation. They were compared to evaluate the precision of the system as well as overall accuracy of final screw placement.ResultsThoracolumbar deformity patients were analyzed, with 153 of 158 screws in adequate position. Only 5 screws were malpositioned, requiring replacement or removal. All 5 were breached laterally and no neurologic or other complications were noted in any of these patients. This resulted in 97 % accuracy using the navigation system, and no neurological injuries or deficits. The average distance of the screw tip and angle of separation for the predicted path versus the final pedicle screw position were analyzed for precision. The mean screw tip distance from the projected tip was 6.43 mm, with a standard deviation of 3.49 mm when utilizing a navigated probe alone and 5.92 mm with a standard deviation of 3.50 mm using a navigated probe and navigated screwdriver (p = 0.23). Mean angle differences were 4.02° and 3.09° respectively (p < 0.01), with standard deviations of 2.63° and 2.12°.ConclusionsThis new technique evaluating precision of screw placement in 3 dimensions improves the ability to define screw placement. Pedicle screw position at final imaging showed the use of StealthStation navigation to be accurate and safe. As this is a preliminary evaluation, we have identified several factors affecting the precision of pedicle screw final position relative to that predicted with navigation.

[1]  V. Schreiber,et al.  Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging. , 2011, Journal of neurosurgery. Spine.

[2]  W. Truong,et al.  The Accuracy of Intraoperative O-arm Images for the Assessment of Pedicle Screw Postion , 2012, Spine.

[3]  Edward C Benzel,et al.  Radiation Exposure to the Spine Surgeon in Lumbar and Thoracolumbar Fusions With the Use of an Intraoperative Computed Tomographic 3-Dimensional Imaging System , 2012, Spine.

[4]  H. Halm,et al.  Morphometric analysis of thoracic and lumbar vertebrae in idiopathic scoliosis. , 2000, Spine.

[5]  A G Patwardhan,et al.  Analysis of the Morphometric Characteristics of the Thoracic and Lumbar Pedicles , 1987, Spine.

[6]  L. Nolte,et al.  [Intraoperative three-dimensional navigation for pedicle screw placement]. , 2004, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen.

[7]  R. Yeasting,et al.  Thoracic pedicle screw placement guided by computed tomographic measurements. , 1999, Journal of spinal disorders.

[8]  H Labelle,et al.  Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. , 2000, Spine.

[9]  H. Halm,et al.  Pedicle Screw Instrumentation of the Thoracic Spine in Idiopathic Scoliosis , 1997, Spine.

[10]  F. Costa,et al.  A Prospective Multicenter Registry on the Accuracy of Pedicle Screw Placement in the Thoracic, Lumbar, and Sacral Levels With the Use of the O-arm Imaging System and StealthStation Navigation , 2012, Spine.

[11]  D. King Internal fixation for lumbosacral fusion. , 1944, The Journal of bone and joint surgery. American volume.

[12]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[13]  D. Polly,et al.  Accuracy of Thoracic Pedicle Screws in Patients with and Without Coronal Plane Spinal Deformities , 2002, Spine.

[14]  A. Dhawan,et al.  In Vivo Accuracy of Thoracic Pedicle Screws , 2001, Spine.

[15]  Rick Sasso,et al.  Comparison of Radiation Exposure in Lumbar Pedicle Screw Placement With Fluoroscopy Vs Computer-Assisted Image Guidance With Intraoperative Three-Dimensional Imaging , 2008, The journal of spinal cord medicine.

[16]  Ahmed A. Aoude,et al.  Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review , 2015, European Spine Journal.

[17]  H H BOUCHER,et al.  A method of spinal fusion. , 1959, The Journal of bone and joint surgery. British volume.

[18]  R. Yeasting,et al.  Anatomic Considerations of Pedicle Screw Placement in the Thoracic Spine: Roy‐Camille Technique Versus Open‐Lamina Technique , 1998, Spine.

[19]  Maria Drangova,et al.  Image performance evaluation of a 3D surgical imaging platform , 2011, Medical Imaging.

[20]  Manuel Arreola,et al.  Use of CT-based intraoperative spinal navigation: management of radiation exposure to operator, staff, and patients. , 2013, World neurosurgery.

[21]  L. Nolte,et al.  Navigation an der Brust- und Lendenwirbelsäule mit dem 3D-Bildwandler , 2004, Der Chirurg.

[22]  S R Garfin,et al.  Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. , 1995, The Journal of bone and joint surgery. American volume.

[23]  Manabu Ito,et al.  Accuracy Analysis of Pedicle Screw Placement in Posterior Scoliosis Surgery: Comparison Between Conventional Fluoroscopic and Computer-Assisted Technique , 2007, Spine.

[24]  S. Hodges,et al.  Analysis of CT-based navigation system for pedicle screw placement. , 2012, Orthopedics.

[25]  H. An,et al.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. , 1995, The Journal of bone and joint surgery. American volume.

[26]  C. K. Lee,et al.  Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic Scoliosis , 1995, Spine.

[27]  X. Weng,et al.  [Complications associated with the technique of pedicle screw fixation]. , 2002, Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae.

[28]  Meic H. Schmidt,et al.  Comparison of Three-Dimensional Fluoroscopy versus Postoperative Computed Tomography for the Assessment of Accurate Screw Placement after Instrumented Spine Surgery , 2012, Global spine journal.

[29]  Vikas V Patel,et al.  Pedicle screw placement with O-arm and stealth navigation. , 2012, Orthopedics.

[30]  B. Jiang,et al.  Accurate Determination of Isthmus of Lumbar Pedicle: A Morphometric Study using Reformatted Computed Tomographic Images , 2004, Spine.

[31]  K. Bulsara,et al.  Utility of Computerized Isocentric Fluoroscopy for Minimally Invasive Spinal Surgical Techniques , 2005, Journal of spinal disorders & techniques.

[32]  M H Krag,et al.  Morphometry of the Thoracic and Lumbar Spine Related to Transpedicular Screw Placement for Surgical Spinal Fixation , 1988, Spine.

[33]  P Merloz,et al.  Pedicle Screw Placement Using Image Guided Techniques , 1998, Clinical orthopaedics and related research.

[34]  R. Winter,et al.  Complications associated with pedicle screws. , 1999, The Journal of bone and joint surgery. American volume.

[35]  Shijian Cai,et al.  Thoracic Pedicle Morphometry in Different Body Height Population: A Three-Dimensional Study Using Reformatted Computed Tomography , 2011, Spine.

[36]  R. Roy-Camille,et al.  [Osteosynthesis of dorsal, lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses]. , 1970, La Presse medicale.

[37]  Nikolaos K. Paschos,et al.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques , 2012, European Spine Journal.

[38]  T. Laine,et al.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients , 2000, European Spine Journal.

[39]  I. Tekdemir,et al.  Thoracic pedicle: surgical anatomic evaluation and relations. , 2001, Journal of spinal disorders.

[40]  J. Weinstein,et al.  Spinal Pedicle Fixation: Reliability and Validity of Roentgenogram-Based Assessment and Surgical Factors on Successful Screw Placement , 1988, Spine.

[41]  D J Quint,et al.  Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine , 2001, Neurosurgery.

[42]  I Anzai,et al.  [Radiation exposure]. , 1968, Sogo kango. Comprehensive nursing, quarterly.

[43]  Kevin T Foley,et al.  Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note. , 2003, Journal of neurosurgery.

[44]  D P McGowan,et al.  Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. , 1990, Spine.

[45]  W. Castro,et al.  Accuracy of Pedicle Screw Placement in Lumbar Vertebrae , 1996, Spine.

[46]  S. Gumina,et al.  Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. , 1999, Spine.

[47]  S. Gertzbein,et al.  Accuracy of Pedicular Screw Placement In Vivo , 1990, Spine.

[48]  Phillip M Young,et al.  Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. , 2009, Journal of neurosurgery. Spine.