Putaminal lesion in multiple system atrophy: postmortem MR-pathological correlations

IntroductionPosterior putaminal atrophy, putaminal T2-hyper and/or hyposignal changes have been observed in patients with multiple system atrophy (MSA) with parkinsonism.MethodsPostmortem T2-weighted images were compared with histological findings in seven autopsy-proven cases of putaminal lesions of MSA. All cases were evaluated on 1.5T magnetic resonance imaging (MRI) scanners and three cases were evaluated on 3T scanners.ResultsThere were three types of putaminal changes: Type 1, mild putaminal atrophy and isointensity; Type 2, putaminal atrophy and diffuse hyperintensity with a hyperintense putaminal rim (HPR); Type 3, putaminal atrophy and iso-or-hypointensity with HPR. The signal intensities of the putamen in Types 1 and 3 were more hypointense on 3T images than on 1.5T images. In Type 1, mild putaminal atrophy showed mild neuronal loss and gliosis and diffuse ferritin deposition. In Types 2 and 3, the areas of putaminal atrophy, severe in the posterior region, showed severe neuronal loss and gliosis, many pigments that were positive for ferritin and Fe 3+ and diffuse ferritin deposition. Although, tissue rarefaction was more severe in Type 2 than in Type 3, pigment deposition was more severe in Type 3. The HPR showed a severe loss of myelin and axons with tissue rarefaction of the external capsule or putaminal rim in Types 2 and 3.ConclusionPosterior putaminal atrophy reflects neuronal loss and gliosis. While putaminal iso-or -hypointensity reflects diffuse ferritin and Fe3+ deposition, hyperintensity reflects tissue rarefaction. The HPR reflects degeneration of the putaminal lateral margin and/or external capsule. These findings reflect characteristic histological findings of MSA with parkinsonism.

[1]  A. Blamire,et al.  Optimising Imaging Parameters for Post Mortem MR Imaging of the Human Brain , 1999, Acta radiologica.

[2]  I Litvan,et al.  Consensus statement on the diagnosis of multiple system atrophy , 1998, Journal of the Neurological Sciences.

[3]  C Trenkwalder,et al.  The combination of hypointense and hyperintense signal changes on T2-weighted magnetic resonance imaging sequences: a specific marker of multiple system atrophy? , 1999, Archives of neurology.

[4]  K. Seppi,et al.  A novel grading scale for striatonigral degeneration (multiple system atrophy) , 2002, Journal of Neural Transmission.

[5]  Mari Yoshida,et al.  Pathological correlate of the slitlike changes on MRI at the putaminal margin in multiple system atrophy , 1999, Journal of Neurology.

[6]  B. Drayer,et al.  Brain magnetic resonance imaging in multiple-system atrophy and Parkinson disease: a diagnostic algorithm. , 2002, Archives of neurology.

[7]  A. Lang,et al.  Striatonigral Degeneration: Iron Deposition in Putamen Correlates with the Slit-like Void Signal of Magnetic Resonance Imaging , 1994, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[8]  R A Zimmerman,et al.  Olivopontocerebellar atrophy: MR diagnosis and relationship to multisystem atrophy. , 1990, Radiology.

[9]  E. Ohama,et al.  Increased iron content in the putamen of patients with striatonigral degeneration , 2004, Acta Neuropathologica.

[10]  D. Dickson,et al.  Multiple System Atrophy: A Sporadic Synucleinopathy , 1999, Brain pathology.

[11]  F. Ye,et al.  Increased Basal Ganglia Iron in Striatonigral Degeneration: In Vivo Estimation with Magnetic Resonance , 1998, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.

[12]  K. Nozaki,et al.  MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences. , 2003, European journal of radiology.

[13]  S. Weis,et al.  Signal changes on MRI and increases in reactive microgliosis, astrogliosis, and iron in the putamen of two patients with multiple system atrophy. , 1996, Journal of neurology, neurosurgery, and psychiatry.

[14]  T. Ogawa,et al.  Hyperintense putaminal rim at 3T reflects fewer ferritin deposits in the lateral marginal area of the putamen. , 2007, AJNR. American journal of neuroradiology.

[15]  A. Lees,et al.  Striatonigral degeneration. A clinicopathological study. , 1990, Brain : a journal of neurology.

[16]  S. Nakamura,et al.  Characteristic MRI findings in multiple system atrophy: comparison of the three subtypes , 2002, Neuroradiology.

[17]  Peter L. Lantos,et al.  Glial cytoplasmic inclusions in the CNS of patients with multiple system atrophy (striatonigral degeneration, olivopontocerebellar atrophy and Shy-Drager syndrome) , 1989, Journal of the Neurological Sciences.

[18]  A J Lees,et al.  Clinical usefulness of magnetic resonance imaging in multiple system atrophy , 1998, Journal of neurology, neurosurgery, and psychiatry.

[19]  Shinn-Zong Lin,et al.  Hyperintense putaminal rim sign is not a hallmark of multiple system atrophy at 3T. , 2005, AJNR. American journal of neuroradiology.

[20]  H U Rehman,et al.  Multiple system atrophy , 2001, Postgraduate medical journal.

[21]  Carlo Colosimo,et al.  Multiple system atrophy , 2004, The Lancet Neurology.