Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial.

OBJECTIVES We hypothesized that human atrial fibrillation (AF) may be sustained by localized sources (electrical rotors and focal impulses), whose elimination (focal impulse and rotor modulation [FIRM]) may improve outcome from AF ablation. BACKGROUND Catheter ablation for AF is a promising therapy, whose success is limited in part by uncertainty in the mechanisms that sustain AF. We developed a computational approach to map whether AF is sustained by several meandering waves (the prevailing hypothesis) or localized sources, then prospectively tested whether targeting patient-specific mechanisms revealed by mapping would improve AF ablation outcome. METHODS We recruited 92 subjects during 107 consecutive ablation procedures for paroxysmal or persistent (72%) AF. Cases were prospectively treated, in a 2-arm 1:2 design, by ablation at sources (FIRM-guided) followed by conventional ablation (n = 36), or conventional ablation alone (n = 71; FIRM-blinded). RESULTS Localized rotors or focal impulses were detected in 98 (97%) of 101 cases with sustained AF, each exhibiting 2.1 ± 1.0 sources. The acute endpoint (AF termination or consistent slowing) was achieved in 86% of FIRM-guided cases versus 20% of FIRM-blinded cases (p < 0.001). FIRM ablation alone at the primary source terminated AF in a median 2.5 min (interquartile range: 1.0 to 3.1 min). Total ablation time did not differ between groups (57.8 ± 22.8 min vs. 52.1 ± 17.8 min, p = 0.16). During a median 273 days (interquartile range: 132 to 681 days) after a single procedure, FIRM-guided cases had higher freedom from AF (82.4% vs. 44.9%; p < 0.001) after a single procedure than FIRM-blinded cases with rigorous, often implanted, electrocardiography monitoring. Adverse events did not differ between groups. CONCLUSIONS Localized electrical rotors and focal impulse sources are prevalent sustaining mechanisms for human AF. FIRM ablation at patient-specific sources acutely terminated or slowed AF, and improved outcome. These results offer a novel mechanistic framework and treatment paradigm for AF. (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation [CONFIRM]; NCT01008722).

[1]  Mandeep Bhargava,et al.  Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: a randomized trial. , 2005, JAMA.

[2]  H. Nakagawa,et al.  Prevention and reversal of atrial fibrillation inducibility and autonomic remodeling by low-level vagosympathetic nerve stimulation. , 2011, Journal of the American College of Cardiology.

[3]  Rahul Mehra,et al.  Comparison of continuous versus intermittent monitoring of atrial arrhythmias. , 2006, Heart rhythm.

[4]  David Keane,et al.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[5]  F. Marchlinski,et al.  Presence of Left-to-Right Atrial Frequency Gradient in Paroxysmal but Not Persistent Atrial Fibrillation in Humans , 2004, Circulation.

[6]  Joshua J. E. Blauer,et al.  Detection and Quantification of Left Atrial Structural Remodeling With Delayed-Enhancement Magnetic Resonance Imaging in Patients With Atrial Fibrillation , 2009, Circulation.

[7]  Stephen S. Cha,et al.  Secular Trends in Incidence of Atrial Fibrillation in Olmsted County, Minnesota, 1980 to 2000, and Implications on the Projections for Future Prevalence , 2006, Circulation.

[8]  Sanjiv M Narayan,et al.  Focal impulse and rotor modulation ablation of sustaining rotors abruptly terminates persistent atrial fibrillation to sinus rhythm with elimination on follow-up: a video case study. , 2012, Heart rhythm.

[9]  Frank Bogun,et al.  Circumferential pulmonary-vein ablation for chronic atrial fibrillation. , 2006, The New England journal of medicine.

[10]  Matthew Wright,et al.  Catheter ablation for atrial fibrillation: are results maintained at 5 years of follow-up? , 2011, Journal of the American College of Cardiology.

[11]  OmerBerenfeld,et al.  Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans , 2005 .

[12]  B. Lindsay,et al.  Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation Patterns , 2010, Circulation.

[13]  David D Spragg,et al.  Long-term single procedure efficacy of catheter ablation of atrial fibrillation , 2006, Journal of Interventional Cardiac Electrophysiology.

[14]  Wen Cheng,et al.  Simultaneous Biatrial Computerized Mapping During Permanent Atrial Fibrillation in Patients with Organic Heart Disease , 2002, Journal of cardiovascular electrophysiology.

[15]  Michel Haïssaguerre,et al.  Disparate evolution of right and left atrial rate during ablation of long-lasting persistent atrial fibrillation. , 2010, Journal of the American College of Cardiology.

[16]  Burr Hall,et al.  Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial. , 2010, JAMA.

[17]  F. Sacher,et al.  Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Critical Structures for Termination , 2005, Journal of cardiovascular electrophysiology.

[18]  C. Tai,et al.  Electrophysiological Characteristics and Catheter Ablation in Patients With Paroxysmal Right Atrial Fibrillation , 2005, Circulation.

[19]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[20]  Wouter-Jan Rappel,et al.  Repolarization and Activation Restitution near Human Pulmonary Veins and Atrial Fibrillation Initiation a Mechanism for the Initiation of Atrial Fibrillation by Premature Beats , 2022 .

[21]  S. Nattel New ideas about atrial fibrillation 50 years on , 2002, Nature.

[22]  S. Ernst,et al.  Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary Veins: Lessons From Double Lasso Technique , 2005, Circulation.

[23]  Sanjiv M. Narayan,et al.  Repolarization Alternans Reveals Vulnerability to Human Atrial Fibrillation , 2011, Circulation.

[24]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[25]  Sanjiv M. Narayan,et al.  Atrial conduction slows immediately before the onset of human atrial fibrillation: a bi-atrial contact mapping study of transitions to atrial fibrillation. , 2012, Journal of the American College of Cardiology.

[26]  中原 志朗,et al.  新しいコンセプトによるアブレーション : Focal Impulse and Rotor Modulation (FIRM)法 (特集 最新の心房細動治療戦略 : 長期持続性心房細動に対するアブレーション) , 2014 .

[27]  H. Wellens,et al.  Predictive factors of sustained sinus rhythm and recurrent atrial fibrillation after a radiofrequency modified Maze procedure. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[28]  C. Morillo,et al.  Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): a prospective, multicenter study. , 2013, JAMA internal medicine.

[29]  G. Feld,et al.  Recovery of Mitral Isthmus Conduction Leads to the Development of Macro-Reentrant Tachycardia After Left Atrial Linear Ablation for Atrial Fibrillation , 2011, Circulation. Arrhythmia and electrophysiology.

[30]  Atul Verma,et al.  Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein Conduction , 2005, Circulation.

[31]  W. Rappel,et al.  Clinical Mapping Approach To Diagnose Electrical Rotors and Focal Impulse Sources for Human Atrial Fibrillation , 2012, Journal of cardiovascular electrophysiology.

[32]  Prashanthan Sanders,et al.  Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation. , 2008, Journal of the American College of Cardiology.

[33]  Wolters Kluwer,et al.  Hrs/ehra/ecas Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design: a Report of the Heart Rhythm Society (hrs) Task Force , 2022 .

[34]  Omer Berenfeld,et al.  Mechanisms of fractionated electrograms formation in the posterior left atrium during paroxysmal atrial fibrillation in humans. , 2011, Journal of the American College of Cardiology.

[35]  A. Skanes,et al.  Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart. , 1998, Circulation.

[36]  Ulrich Schotten,et al.  Electropathological Substrate of Long-Standing Persistent Atrial Fibrillation in Patients With Structural Heart Disease: Longitudinal Dissociation , 2010, Circulation. Arrhythmia and electrophysiology.

[37]  Leora Peltz,et al.  Epicardial Mapping of Chronic Atrial Fibrillation in Patients: Preliminary Observations , 2004, Circulation.

[38]  José Jalife,et al.  Cardiac fibrillation: from ion channels to rotors in the human heart. , 2008, Heart rhythm.