Three-dimensional optical tomography of the premature infant brain

For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have been reconstructed using measurements of mean flight time relative to those acquired on a homogeneous reference phantom, and using a head-shaped 3D finite-element-based forward model with an external boundary constrained to match the measured positions of the sources and detectors. Results are presented for a premature infant with a cerebral haemorrhage predominantly located within the left ventricle. Images representing the distribution of absorption at 780 nm and 815 nm reveal an asymmetry consistent with the haemorrhage, and corresponding maps of blood volume and fractional oxygen saturation are generally within expected physiological values.

[1]  A. Hamlyn Letter: Blood-ethanol in liver disease. , 1975, Lancet.

[2]  F. Jöbsis Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. , 1977, Science.

[3]  J. Brazy,et al.  Noninvasive monitoring of cerebral oxygenation in preterm infants: preliminary observations. by brazy je, lewis dv, mitnick mh, and joubsis vander vliet ff. pediatrics 1985; 75:217–225 , 1985, Pediatrics.

[4]  J. Brazy,et al.  Noninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations , 1985, Pediatrics.

[5]  Susan Wray,et al.  QUANTIFICATION OF CEREBRAL OXYGENATION AND HAEMODYNAMICS IN SICK NEWBORN INFANTS BY NEAR INFRARED SPECTROPHOTOMETRY , 1986, The Lancet.

[6]  D. Delpy,et al.  COTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY , 1988, The Lancet.

[7]  M. Cope,et al.  New non-invasive methods for assessing brain oxygenation and haemodynamics. , 1988, British medical bulletin.

[8]  D. Delpy,et al.  Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy. , 1990, Journal of applied physiology.

[9]  L. Skov,et al.  Estimating Cerebral Blood Flow in Newborn Infants: Comparison of Near Infrared Spectroscopy and 133Xe Clearance , 1991, Pediatric Research.

[10]  P. V. D. Zee,et al.  Measurement and modelling of the optical properties of human tissue in the near infrared , 1992 .

[11]  J. Wyatt,et al.  Near-infrared spectroscopy in asphyxial brain injury. , 1993, Clinics in perinatology.

[12]  D A Benaron,et al.  Non-recursive linear algorithms for optical imaging in diffusive media. , 1994, Advances in experimental medicine and biology.

[13]  Near‐infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation , 1995, Current opinion in pediatrics.

[14]  Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation. , 1995 .

[15]  D. Delpy,et al.  Recent advances in fetal near infrared spectroscopy. , 1997, Journal of biomedical optics.

[16]  V Dietz,et al.  Measurement of absolute cerebral haemoglobin concentration in adults and neonates. , 1997, Advances in experimental medicine and biology.

[17]  M. Schweiger,et al.  Image reconstruction in optical tomography. , 1997, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[18]  B Chance,et al.  Use of near infrared spectroscopy to identify traumatic intracranial hemotomas. , 1997, Journal of biomedical optics.

[19]  P M Schlag,et al.  Frequency-domain techniques enhance optical mammography: initial clinical results. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[20]  B. Chance,et al.  A novel method for fast imaging of brain function, non-invasively, with light. , 1998, Optics express.

[21]  Britton Chance,et al.  TIME-CORRELATED SINGLE PHOTON COUNTING IMAGER FOR SIMULTANEOUS MAGNETIC RESONANCE AND NEAR-INFRARED MAMMOGRAPHY , 1998 .

[22]  Joshua L. Duckworth,et al.  Stationary Headband for Clinical Time‐of‐Flight Optical Imaging at the Bedside , 1998, Photochemistry and photobiology.

[23]  J. Marota,et al.  Design and evaluation of a continuous-wave diffuse optical tomography system. , 1999, Optics Express.

[24]  S R Arridge,et al.  Simultaneous reconstruction of absorption and scattering images by multichannel measurement of purely temporal data. , 1999, Optics letters.

[25]  S. Arridge Optical tomography in medical imaging , 1999 .

[26]  Yukio Yamada,et al.  Multichannel time-resolved optical tomographic imaging system , 1999 .

[27]  Clare E Elwell,et al.  Abnormal cerebral haemodynamics in perinatally asphyxiated neonates related to outcome , 1999, Archives of disease in childhood. Fetal and neonatal edition.

[28]  Association of the Hedgehog Receptor Patched with Caveolin-1 , 1999 .

[29]  Wai-Fung Cheong,et al.  Bedside Imaging of Intracranial Hemorrhage in the Neonate Using Light: Comparison with Ultrasound, Computed Tomography, and Magnetic Resonance Imaging , 1999, Pediatric Research.

[30]  D. Benaron,et al.  Bedside Imaging of Intracranial Hemorrhage in the Neonate Using Light: Comparison with Ultrasound, Computed Tomography, and Magnetic Resonance Imaging , 1999, Pediatric Research.

[31]  M. Schweiger,et al.  Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography. , 2000, Applied optics.

[32]  A. Kleinschmidt,et al.  Noninvasive Functional Imaging of Human Brain Using Light , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[33]  Atsushi Maki,et al.  Spontaneous oscillation of oxy- and deoxy- hemoglobin changes with a phase difference throughout the occipital cortex of newborn infants observed using non-invasive optical topography , 2000, Neuroscience Letters.

[34]  D. Delpy,et al.  A 32-channel time-resolved instrument for medical optical tomography , 2000 .

[35]  T. Kusaka,et al.  Changes in cerebral hemoglobin concentration and oxygen saturation immediately after birth in the human neonate using full-spectrum near infrared spectroscopy. , 2000, Journal of biomedical optics.

[36]  D. Boas,et al.  Bedside functional imaging of the premature infant brain during passive motor activation , 1999, Photonics West - Biomedical Optics.

[37]  S R Arridge,et al.  Three-dimensional time-resolved optical tomography of a conical breast phantom. , 2001, Applied optics.

[38]  A. Hielscher,et al.  Instrumentation for fast functional optical tomography , 2002 .

[39]  J. Mandeville,et al.  The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics , 2001, NeuroImage.

[40]  S R Arridge,et al.  Time resolved optical tomography of the human forearm. , 2001, Physics in medicine and biology.

[41]  D Boas,et al.  Simultaneous imaging and optode calibration with diffuse optical tomography. , 2001, Optics express.

[42]  B. Pogue,et al.  A parallel-detection frequency-domain near-infrared tomography system for hemoglobin imaging of the , 2001 .

[43]  A. Hielscher,et al.  Three-dimensional optical tomography of hemodynamics in the human head. , 2001, Optics express.

[44]  Simon R. Arridge,et al.  Optical Tomography of the Breast using a 32-Channel Time-Resolved Imager , 2002 .

[45]  Hillman Emc,et al.  Experimental and theoretical investigations of near infrared tomographic imaging methods and clinical applications. , 2002 .

[46]  Fabrizio Martelli,et al.  Assessment of an in situ temporal calibration method for time-resolved optical tomography. , 2003, Journal of biomedical optics.