Evaluation of Effective Dose Using the k-Factor of Optimal Scan Range for CT Examination

The American College of Radiology opened the computed tomography (CT) dose index registry (DIR) for general participation by all facilities in 2011. For each CT examination, data on volume CT dose index (CTDIvol), dose-length product (DLP), and, for body examinations, size-specific dose estimate (SSDE) were collected. However, effective dose is not estimated in DIR. The primary objective of this study was to estimate k-factor profile in detail at various scan positions with modified the ImPACT CT patient dosimetry. A tool that easily estimates the k-factor of suitable scan areas is essential for practical dose estimation in the DIR. We evaluated k-factor (effective dose/ DLP) profiles between a medical international radiation dose-five (MIRD-5) phantom positions using aImPACT software. As a result of this study, practicality of the k-factor profile method in clinical use was clarified. We speculate that a flexible k-factor improves the appropriateness of the E in hospital settings.

[1]  Andrew E Arai,et al.  Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320 – Detector Row Volume Scanner 1 , 2010 .

[2]  D. G. Jones,et al.  Normalised Organ Doses for X Ray Computed Tomography Calculated Using Monte Carlo Techniques and a Mathematical Anthropomorphic Phantom , 1993 .

[3]  M. Charles Effects of Ionizing Radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2006 Report, Volume 1—Report to the General Assembly, with Scientific Annexes A and B , 2010 .

[4]  J. Boone,et al.  Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations , 2011 .

[5]  Richard L Morin,et al.  The ACR Computed Tomography Dose Index Registry: the 5 million examination update. , 2013, Journal of the American College of Radiology : JACR.

[6]  C. H. Clement,et al.  The Impact of the 2007 Recommendations of the International Commission on Radiological Protection (ICRP) in Medical Applications , 2009 .

[7]  W. Paul Segars,et al.  Organ doses, effective doses, and risk indices in adult CT: comparison of four types of reference phantoms across different examination protocols. , 2012, Medical physics.

[8]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[9]  J. Valentin,et al.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102. , 2007, Annals of the ICRP.

[10]  Paul C Shrimpton,et al.  Effective dose and dose-length product in CT. , 2009, Radiology.

[11]  Kazuhiro Katada,et al.  Evaluation of organ doses and effective dose according to the ICRP Publication 110 reference male/female phantom and the modified ImPACT CT patient dosimetry , 2014, Journal of applied clinical medical physics.