Fast circuit topology for spatial signal distribution analysis

We present a novel active and analog readout and preprocessing topology for position sensitive photodetectors (PSPD) that allows to readout a large variety of PSPD devices with different pixel numbers. Additionally, the topology was designed to allow for a significant reduction of analog-to-digital conversion channels. The circuit topology replaces the common passive charge divider and consists of N input stages, N × M weighting stages and M analog adder stages, where N is the number of the input channels, i.e. the number of photodetector pixels and M is the number of outputs. The circuit performs the multiplication of a matrix (the weights) with a vector (signals). For this, the input stage makes M copies of each of the N input signals, the weighting stage multiplies these signal copies with N × M different weights and the output stage adds all weighted copies with the same copy index. For high flexibility, the weights are programmable and the topology allows to interconnect several identical circuits for larger N. As application for the circuit, we present a Neural Network based positioning scheme for γ-ray imaging detectors with thick, monolithic scintillation crystals. We used Monte Carlo simulation for training and evaluation of the method and found that the spatial resolution of the γ-ray imaging detectors was significantly enhanced. The strong border artifacts of the center of gravity positioning scheme in monolithic scintillation crystals could be corrected to a large extent.

[1]  Robert W. Parkey,et al.  3D position readout from thick scintillators , 2002 .

[2]  Huafeng Liu,et al.  Development of a depth of interaction detector for γ-rays , 2001 .

[3]  Depth of interaction detection with enhanced position-sensitive proportional resistor network , 2005 .

[4]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[5]  Xiaochuan Pan,et al.  Accurate image reconstruction using DOI information and its implications for the development of compact PET systems , 2000 .

[6]  A. Sebastia,et al.  Depth of /spl gamma/-ray interaction within continuous crystals from the width of its scintillation light-distribution , 2005, IEEE Transactions on Nuclear Science.

[7]  Magnus Dahlbom,et al.  PET system calibrations and corrections for quantitative and spatially accurate images , 1989 .

[8]  V. Herrero-Bosch,et al.  AMIC: An Expandable Front-End for Gamma-Ray Detectors With Light Distribution Analysis Capabilities , 2011, IEEE Transactions on Nuclear Science.

[9]  Néstor Ferrando,et al.  Depth of interaction detection for γ-ray imaging☆ , 2009 .

[10]  H. Barrett,et al.  Maximum-likelihood estimation of 3D event position in monolithic scintillation crystals: Experimental results , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[11]  M. Rafecas,et al.  A Monte Carlo study of high resolution PET with granulated dual layer detectors , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[12]  C. Morel,et al.  Development of a 3D position sensitive scintillation detector using neural networks , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[13]  S. Meikle,et al.  Design and simulation of continuous scintillator with pixellated photodetector , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[14]  D. P. Saylor,et al.  Design of an efficient position sensitive gamma ray detector for nuclear medicine. , 1986, Physics in medicine and biology.

[15]  Joel S. Karp,et al.  Design and performance of a new positron tomograph , 1988 .

[16]  T. Lewellen,et al.  cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme☆ , 2002 .

[17]  Néstor Ferrando,et al.  High-precision position estimation in PET using artificial neural networks , 2009 .

[18]  S. Tavernier,et al.  Neural network-based position estimators for PET detectors using monolithic LSO blocks , 2004, IEEE Transactions on Nuclear Science.

[19]  A. R. Ricci,et al.  Development of continuous detectors for a high resolution animal PET system , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[20]  Michael V. Green,et al.  Depth identification accuracy of a three layer phoswich PET detector module , 1999 .

[21]  J. Benlloch,et al.  Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement , 2009 .

[22]  L. Jones,et al.  On moment inversion , 1986 .

[23]  H. Murayama,et al.  Performance evaluation of a subset of a four-layer LSO detector for a small animal DOI PET scanner: jPET-RD , 2006, IEEE Transactions on Nuclear Science.

[24]  M. Maas,et al.  Experimental characterization of monolithic-crystal small animal PET detectors read out by APD arrays , 2006, IEEE Transactions on Nuclear Science.

[25]  H. Anger,et al.  MAPPING THE DISTRIBUTION OF GAMMA-RAY-EMITTING ISOTOPES WITH THE SCINTILLATION CAMERA , 1958 .

[26]  G. Talenti Recovering a function from a finite number of moments , 1987 .

[27]  William W. Moses,et al.  Design studies for a PET detector module using a PIN photodiode to measure depth of interaction , 1994 .

[28]  Joel S. Karp,et al.  Depth-of-interaction determination in NaI(Tl) and BGO scintillation crystals using a temperature gradient , 1987 .

[29]  R S Miyaoka,et al.  Depth of interaction decoding of a continuous crystal detector module , 2007, Physics in medicine and biology.

[30]  I. M. Tkachenko,et al.  Reconstruction of distributions by their moments and local constraints , 2003 .

[31]  J. G. Rogers,et al.  A practical block detector for a depth encoding PET camera , 1995 .

[32]  J. Benlloch,et al.  Dependency of Energy-, Position- and Depth of Interaction Resolution on Scintillation Crystal Coating and Geometry , 2008, IEEE Transactions on Nuclear Science.

[33]  Yiping Shao,et al.  Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[34]  D. Schlyer,et al.  An improved Anger detector approach for PET with high resolution and sensitivity , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[35]  R. Gadea,et al.  Corrected position estimation in PET detector modules with multi-anode PMTs using neural networks , 2005, IEEE Transactions on Nuclear Science.

[36]  R. Nutt,et al.  A Multicrystal Two Dimensional BGO Detector System for Positron Emission Tomography , 1986, IEEE Transactions on Nuclear Science.

[37]  Christoph W. Lerche,et al.  AMIC: An expandable front-end for gamma-ray detectors with light distribution analysis capabilities , 2010, 2010 17th IEEE-NPSS Real Time Conference.

[38]  P. Bartzakos,et al.  A depth-encoded PET detector , 1990 .

[39]  C. Ordonez,et al.  A depth-encoding Anger detector using scintillating fibers , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).