Photodegradation of polyaromatic hydrocarbons in passive air samplers: field testing different deployment chambers.

Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation.

[1]  Michael Matthies,et al.  Selecting internally consistent physicochemical properties of organic compounds , 2002, Environmental toxicology and chemistry.

[2]  Michael Bartkow,et al.  Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs) , 2004 .

[3]  P. Bergqvist,et al.  Passive air sampling using semipermeable membrane devices at different wind-speeds in situ calibrated by performance reference compounds. , 2004, Environmental science & technology.

[4]  D. Mackay,et al.  Variability of concentrations of polybrominated diphenyl ethers and polychlorinated biphenyls in air: implications for monitoring, modeling and control , 2005 .

[5]  Gary Stern,et al.  Using passive air samplers to assess urban-rural trends for persistent organic pollutants. 1. Polychlorinated biphenyls and organochlorine pesticides. , 2004, Environmental science & technology.

[6]  R. Gale,et al.  Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants. , 2000, Journal of chromatography. A.

[7]  K. Jones,et al.  Further developments in the use of semipermeable membrane devices as passive air samplers: application to PCBs. , 2001, Environmental science & technology.

[8]  Y. Lei,et al.  Atmospheric distribution and long-range transport behavior of organochlorine pesticides in North America. , 2005, Environmental science & technology.

[9]  A. Sweetman,et al.  Passive air sampling of polycyclic aromatic hydrocarbons and polychlorinated naphthalenes across europe , 2004, Environmental toxicology and chemistry.

[10]  G. O. Thomas,et al.  Passive Air Sampling of PCBs: Field Calculation of Atmospheric Sampling Rates by Triolein-Containing Semipermeable Membrane Devices , 1998 .

[11]  D. Hawker,et al.  Characterizing uptake kinetics of PAHs from the air using polyethylene-based passive air samplers of multiple surface area-to-volume ratios. , 2004, Environmental science & technology.

[12]  D. Hawker,et al.  Passive air sampling theory for semivolatile organic compounds. , 2005, Chemosphere.

[13]  Tom Harner,et al.  Characterization and comparison of three passive air samplers for persistent organic pollutants. , 2002, Environmental science & technology.

[14]  K. Jones,et al.  Further developments in the use of semipermeable membrane devices (SPMDs) as passive air samplers for persistent organic pollutants: field application in a spatial survey of PCDD/Fs and PAHs. , 2001, Environmental science & technology.

[15]  K. Jones,et al.  Spatial and temporal trends of POPs in Norwegian and UK background air: implications for global cycling. , 2003, Environmental science & technology.