3D vasculature segmentation using localized hybrid level-set method
暂无分享,去创建一个
Beizhan Wang | Qingqi Hong | Junfeng Yao | Qingde Li | Yan Li | Kunhong Liu | Qingqiang Wu
[1] Yin Wang,et al. A Nonparametric Shape Prior Constrained Active Contour Model for Segmentation of Coronaries in CTA Images , 2014, Comput. Math. Methods Medicine.
[2] Denis Kouame,et al. New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices , 2014, Comput. Math. Methods Medicine.
[3] Beizhan Wang,et al. Segmentation of vessel images using a localized hybrid level-set method , 2013, 2013 6th International Congress on Image and Signal Processing (CISP).
[4] Sim Heng Ong,et al. A new unified level set method for semi-automatic liver tumor segmentation on contrast-enhanced CT images , 2012, Expert Syst. Appl..
[5] Jie Tian,et al. Partial shape-preserving splines , 2011, Comput. Aided Des..
[6] Stephane Cotin,et al. Segmentation and reconstruction of vascular structures for 3D real-time simulation , 2011, Medical Image Anal..
[7] Isabelle Bloch,et al. A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes , 2009, Medical Image Anal..
[8] Chunming Li,et al. Minimization of Region-Scalable Fitting Energy for Image Segmentation , 2008, IEEE Transactions on Image Processing.
[9] Ken Masamune,et al. A Variational Method for Geometric Regularization of Vascular Segmentation in Medical Images , 2008, IEEE Transactions on Image Processing.
[10] L.-K. Shark,et al. Medical Image Segmentation Using New Hybrid Level-Set Method , 2008, 2008 Fifth International Conference BioMedical Visualization: Information Visualization in Medical and Biomedical Informatics.
[11] Max W. K. Law,et al. Weighted Local Variance-Based Edge Detection and Its Application to Vascular Segmentation in Magnetic Resonance Angiography , 2007, IEEE Transactions on Medical Imaging.
[12] Chunming Li,et al. Implicit Active Contours Driven by Local Binary Fitting Energy , 2007, 2007 IEEE Conference on Computer Vision and Pattern Recognition.
[13] Ashraf A. Kassim,et al. Segmentation of volumetric MRA images by using capillary active contour , 2006, Medical Image Anal..
[14] Chunming Li,et al. Level set evolution without re-initialization: a new variational formulation , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).
[15] Anthony J. Yezzi,et al. Vessel Segmentation Using a Shape Driven Flow , 2004, MICCAI.
[16] Ronald Fedkiw,et al. Level set methods and dynamic implicit surfaces , 2002, Applied mathematical sciences.
[17] Olivier D. Faugeras,et al. CURVES: Curve evolution for vessel segmentation , 2001, Medical Image Anal..
[18] Kaleem Siddiqi,et al. Flux maximizing geometric flows , 2001, Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001.
[19] L. Vese,et al. Active contours without edges , 2001, IEEE Trans. Image Process..
[20] Amir A. Amini,et al. Quantitative coronary angiography with deformable spline models , 1997, IEEE Transactions on Medical Imaging.
[21] I E Magnin,et al. Improved vessel visualization in MR angiography by nonlinear anisotropic filtering , 1997, Magnetic resonance in medicine.
[22] Demetri Terzopoulos,et al. Deformable models in medical image analysis: a survey , 1996, Medical Image Anal..
[23] R. Kimmel,et al. Geodesic Active Contours , 1995, Proceedings of IEEE International Conference on Computer Vision.
[24] J. Sethian,et al. Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations , 1988 .
[25] João Manuel R. S. Tavares,et al. A Review on the Current Segmentation Algorithms for Medical Images , 2009, IMAGAPP.
[26] John G. Griffiths,et al. Constructive implicit fitting , 2006, Comput. Aided Geom. Des..
[27] Demetri Terzopoulos,et al. Snakes: Active contour models , 2004, International Journal of Computer Vision.
[28] L. Antiga. Patient-specific modeling of ge-ometry and blood flow in large arteries , 2003 .
[29] H. Soner,et al. Level set approach to mean curvature flow in arbitrary codimension , 1996 .
[30] Benoit M. Dawant,et al. Morphometric analysis of white matter lesions in MR images: method and validation , 1994, IEEE Trans. Medical Imaging.